Introduction 

 

 

 

 

Instruction manual 977 Tank Side Indicator 

 

 

 

   Page 5  

 

Introduction 

 

1.1  Functional description 

 
The 977 Tank Side Indicator (TSI) is designed to display the level, temperature or other gauge data from the 
Honeywell Enraf series 854 servo gauges or the 970/971/973 SmartRadar. 
 

Note: 

The Tank Side Indicator can only be connected to the servo gauge if the servo gauge is equipped with the 
XPU-2 board with the i.s. option (XPU-2/i.s.).  
The Tank Side Indicator can only be connected to the 970 or 971 or 973 SmartRadar if the radar gauge is 
equipped with the i.s. output option for 977 TSI (ICU_IS2 board). 

 
The LCD display of the 977 Tank Side Indicator has two 16-characters lines. Incase of the 854 XTG Servo 
gauge and 970/971/973 SmartRadar, which have no display, the TSI provides the display function. 
 
The 977 Tank Side Indicator can be installed at ground level or in any other convenient place in the vicinity of 
the tank, provided the distance to the level gauge is not more than 250 metres (820 ft). 
 
Only one cable (2 cores) is required for the electrical connection of the 977 TSI. The supply for the 977 TSI is 
provided by the level gauge and is intrinsically safe (EEx - ib). The data transmission for the 977 TSI is 
superimposed on the supply lines (FSK based on the Bell 202 modem standard). 
 
This manual gives information on: 

  Items to be set in the level gauge for the different display functions of the 977 TSI (854 XTG and 

970/971/973 SmartRadar only) 

  Diagnostic information on the Tank Side indicator and on the level gauges 

  Display functions of the 854 ATG / XTG and 970/971/973 SmartRadar 

 
 

1.2  Operating principle 

 
For firmware version previous A3.0: 
The 977 Tank Side Indicator continuously asks the level gauge for items 

1A

 (upper display row display format 

A) and 

2A

 (lower display row display format A).  

 
For firmware version A3.0 and higher: 
After power up and the initial message, the 977 Tank Side Indicator request for display format (item 

DF

) of the 

level gauge. With that information, the 977 TSI continuously asks the level gauge for the selected display format 
(upper and lower display row). 
 
The refresh rate is approximately once per second. An “alive” indication is given in the last character on the 
upper display row of the Tank Side Indicator by a blinking (on/off) “underscore” (_). 
 
If the communication between the Tank Side Indicator and the level gauge fails for more than 5 or 15 seconds 
(the interval time is adjustable), the display information on the 977 TSI is removed and replaced by diagnostic 
information about the communication error. 
 
With the optional keyboard consisting of four membrane keys, the different display formats of the level gauge 
can be selected and, for servo gauges, gauges commands can be given. 

Содержание Enraf 977

Страница 1: ...Instruction manual 977 Tank Side Indicator ...

Страница 2: ......

Страница 3: ...age 1 Instruction manual 977 Tank Side Indicator August 2011 Part no 4416 266 Revision 5 Enraf B V P O Box 812 2600 AV Delft Netherlands Tel 31 15 2701100 Fax 31 15 2701111 E mail hfs tac support honeywell com Website http www honeywellenraf com ...

Страница 4: ...This manual is for information only The contents descriptions and specifications are subject to change without notice Enraf B V accepts no responsibility for any errors that may appear in this manual The warranty terms and conditions for Honeywell Enraf products applicable in the country of purchase are available from your supplier Please retain them with your proof of purchase ...

Страница 5: ...y only be conducted by qualified engineers trained by Honeywell Enraf and with knowledge of safety regulations for working in hazardous areas The information in this manual is the copyright property of Enraf BV Netherlands Enraf BV disclaims any responsibility for personal injury or damage to equipment caused by Deviation from any of the prescribed procedures Execution of activities that are not p...

Страница 6: ...nal safety 6 2 3Safety conventions 6 3 Commissioning 7 3 1Display settings 7 3 2Pincode for keyboard commands 7 3 3Adjustment of display contrast 8 3 4Communication time out selection 8 4 Operation 9 4 1Display 9 4 2Scrolling through display formats 9 4 3Gauge commands for 854 ATG XTG 10 5 Troubleshooting 11 Appendix A Display formats servo gauges 12 Appendix B Display formats SmartRadar LT 17 App...

Страница 7: ...d on the Bell 202 modem standard This manual gives information on Items to be set in the level gauge for the different display functions of the 977 TSI 854 XTG and 970 971 973 SmartRadar only Diagnostic information on the Tank Side indicator and on the level gauges Display functions of the 854 ATG XTG and 970 971 973 SmartRadar 1 2 Operating principle For firmware version previous A3 0 The 977 Tan...

Страница 8: ... hazardous areas 2 3 Safety conventions Warnings Cautions and Notes have been used throughout this manual to bring special matters to the immediate attention of the reader A Warning concerns danger to the safety of the technician or user A Caution draws attention to an action which may damage the equipment A Note points out a statement deserving more emphasis than the general text but not requirin...

Страница 9: ...ero with slash EX Exit Exit protection level 2 3 2 Pincode for keyboard commands Only valid with 977 TSI firmware A3 0 When the 977 Tank Side Indicator is equipped with the optional keyboard a pincode must be specified in the servo gauge The chosen pincode is to be issued from the indicator keyboard before the command is executed The indicator keyboard has four keys with arrows left down up and ri...

Страница 10: ...3 3 Adjustment of display contrast If required the contrast of the display can be adjusted When the cover of the Tank Side Indicator is removed a potentiometer can be reached through a hole in the chassis plate on the left hand side of the display refer to fig 3 2 Turning the potentiometer clockwise will increase the display contrast while turning the potentiometer counter clockwise decreases the ...

Страница 11: ...Return to TSI housing Connect the PCB ground connection place the PCB assembly in the housing and secure it with the two screws A Place connector CN1 and close the cover For TSI versions with a strap block Remove the cover from the 977 TSI by loosening the four screws at the corner Remove the connector CN1 wiring can be left connected Loosen the two screws marked A in figure 3 2 Lift TSI printed c...

Страница 12: ...splay of the Tank Side Indicator shows the default display format from the level gauge set by item DF This is valid from TSI firmware version A3 0 or higher For previous firmware versions the display shows the level and temperature display format A from the level gauge By operating the keyboard one can scroll through all other display formats of the level gauge The display formats are Figure 4 1 T...

Страница 13: ...en pressing the arrow right R key a selection can be made out of 12 gauge commands Scrolling through the gauge commands is done by the arrow down D key or arrow up U key similar as with display scrolling The gauge commands are in this order when scrolled by arrow down key Interface 1 Interface 2 Interface 3 Block Calibrate Dip mode Freeze Interface Profile Lock Test Test Gauge Tank Profile Unlock ...

Страница 14: ... When the desired gauge command appears on the display press the arrow right R key The gauge command will be executed and the Tank Side Indicator returns to the default display Note If the default display format is A or B the execution of a gauge command can directly be observed To leave the gauge command menu without performing a gauge command is done by pressing the arrow left L key Then the Tan...

Страница 15: ...n Tank Side Indicator and level gauge Reset level gauge by means of RS command Either replace TSI or XPU 2 i s board with servo gauges or ICU_IS2 board with 970 971 973 SmartRadar With TSI firmware version A3 0 and higher The following internal 977 Tank Side Indicator errors are detected and displayed Display Meaning of error and how to solve INTERNAL RAM DEFECT Internal RAM defect replace PCB ass...

Страница 16: ...g actions can be taken to solve the problem Check cabling between Tank Side Indicator and level gauge Reset level gauge by means of RS command Either replace TSI or XPU 2 i s board with servo gauges or ICU_IS2 board with 970 971 93 SmartRadar If the level gauge detects an error in the communication with the Tank Side Indicator there will be no reply to the Tank Side Indicator The communication err...

Страница 17: ...truction manual 977 Tank Side Indicator Page 15 Appendix A Display formats servo gauges This appendix gives an overview of the ten different display formats of the 854 ATG XTG Level and temperature display format A ...

Страница 18: ...Appendix Page 16 Instruction manual 977 Tank Side Indicator Level display format B Average gas temperature display format C ...

Страница 19: ...Appendix Instruction manual 977 Tank Side Indicator Page 17 Average product temperature format D HIMS density display format E ...

Страница 20: ...Appendix Page 18 Instruction manual 977 Tank Side Indicator HIMS pressure display format F and H Servo density display format I ...

Страница 21: ...Appendix Instruction manual 977 Tank Side Indicator Page 19 Analog level output display format J Water level display format K ...

Страница 22: ...ay formats SmartRadar In appendix B the level display formats display format A and B are given for the 970 971 973 SmartRadar Other display formats are same as with 854 ATG XTG Display format I servo density does not exist in SmartRadar LT Level and temperature display format A ...

Страница 23: ...Appendix Instruction manual 977 Tank Side Indicator Page 21 Level display format B ...

Страница 24: ... Installation guide 854 Advanced Technology Gauge Installation guide 970 SmartRadar ATi Installation guide 971 SmartRadar LTi Installation guide 973 SmartRadar LT Instruction manual series 854 XTG level gauge Instruction manual series 854 ATG level gauge Instruction manual 970 SmartRadar ATi Instruction manual 971 SmartRadar LTi Instruction manual 973 SmartRadar LT ...

Страница 25: ...upper display row 5 Error messages 11 Gauge commands 10 Generic emission standard 3 immunity standard 3 Host Command mode 10 i s option 5 ICU_IS board 11 Items 0B 7 8 10 1A 5 2A 5 DG 7 DJ 7 HC 10 Keyboard 5 7 9 Level 5 Note 6 Other gauge data 5 Pincode 7 10 TSI 8 Refresh rate 5 Related documents 19 Safety 6 Supply 5 Temperature 5 Tenth millimetre selection 7 Transmission 5 Warning 6 XPU 2 board 5 ...

Страница 26: ......

Страница 27: ......

Страница 28: ...neywell Enraf Delftechpark 39 2628 XJ Delft The Netherlands Tel 31 0 15 2701 100 Email hfs tac support honeywell com www honeywellenraf com 4416266 Revision 5 August 2011 2011 Honeywell International Inc ...

Отзывы: