background image

9

32-00069—01

Figure 3.3. 

Draft Breaking Hood

A draft breaking hood is an open connection between the
heater tube exhaust and the exhaust stack. It allows fresh
dilution air to pass into the exhaust and mix with the
exhaust gases.

The advantages of a draft hood are:

•  the burner operation is less sensitive to atmospheric

conditions.

•  the temperature of the exhaust gases is lower when

they pass through the roof.

NOTE: 

Leave access between the draft hood and the tube

exhaust. Install a damper plate if acoustic feedback
occurs in the tube.

Condensate provisions

If the immersion tube will operate at efficiencies less than
80%, the exhaust leg can be raised through the liquid
surface. For efficiencies of 80% or higher, locate the
exhaust stack outside of the tank and provide a drain. See
Figures 3.4 and 3.5.

NOTE:

 Regardless of the exhaust design, pitch the

immersion tube down towards the exhaust so condensate
will not collect at the burner.

  At efficiencies of 80% or greater, low exhaust

temperatures will cause condensation to form in
the tube at start-up or during long idling periods.
The higher the efficiency the more condensation
will increase.

 

To prevent condensation/corrosion from
shortening tube life or disrupting burner
operation, provide a condensate drain at the
exhaust and slope the immersion tube downward,
away from the burner.

Figure 3.4. Efficiencies less than 80%

Figure 3.5. Efficiencies 80% or more

Tube placement in tank

The tube placement height in the tank should be high
enough to avoid the possibility of sludge build-up on the
bottom of the tank; however, it should be low enough to
avoid tube exposure due to liquid level variations caused
by evaporation or displacement. In the latter case use a
liquid level switch to shut down the burner

Step 3: Control System

Control Methodology

ImmersoJet burners use a modulating on-ratio control
system as shown in Figure 3.3. To control the heat
delivered by the burner, adjust the air flow to the burner.
The gas flow will change in proportion to the air flow.

The burner will operate reliably at any input between the
low fire and high fire limits stated on the burner‘s
datasheet.

Stack

Draft Breaking

Hood

Dilution Air

Tube Exhaust

CAUTION

Stack -
Twice
Tube
Diameter

1/2 inch
Drain
Pipe

Содержание Eclipse ImmersoJet

Страница 1: ...Eclipse ImmersoJet Burner Version 3 IJ Series 11 15 2016 Design Guide 330 ...

Страница 2: ...Eclipse will not be liable for any other injury loss damage or expenses whether direct or consequential including but not limited to loss of use income or damage to material arising in connection with the sale installation use of inability to use or the repair or replacement of Eclipse s products Any operation expressly prohibited in this manual any adjustment or assembly procedures not recommende...

Страница 3: ...ies 5 Operator Training 5 Replacement Parts 5 3 System Design 6 Design 6 Step 1 Burner Model Selection 6 Step 2 Tube Design 7 Step 3 Control System 9 Step 4 Ignition System 10 Step 5 Flame Monitoring System 10 Step 6 Combustion Air System 11 Step 7 Main Gas Shut Off Valve Train 13 Step 8 Process Temperature Control System 13 Appendix i Key to System Schematics ii iii Notes iv ...

Страница 4: ...less tank space is occupied by the tubes With a combustion chamber that is integral to the burner body the new version of the ImmersoJet can sit lower on the tank than previous ImmersoJet models Audience This manual has been written for personnel already familiar with all aspects of an immersion burner and its add on components also referred to as the burner system These aspects include Design sel...

Страница 5: ...kets boards or gaskets Despite these efforts dust created by sanding sawing grinding cutting and other construction activities could release crystalline silica Crystalline silica is known to cause cancer and health risks from the exposure to these chemicals vary depending on the frequency and length of exposure to these chemicals To reduce the risk limit exposure to these chemicals work in a well ...

Страница 6: ... economy and tube length Small diameter tubes occupy less tank space than conventional tubes however so their length can easily be increased to provide efficiencies of 80 or more Calculate the Gross Burner Input Use this formula to calculate gross burner input in Btu h Fuel Type If using an alternative fuel supply contact Eclipse with an accurate breakdown of the fuel components Applications Requi...

Страница 7: ...del Choose a burner model with a maximum capacity greater than the gross burner input calculated previously Refer to Table 3 2 Step 2 Tube Design Determine Effective Tube Length Find the required effective tube length using the previously selected tube efficiency net heat input values and Figures 3 1 or 3 2 The effective length of a tube is the total centerline length of the tube covered by liquid...

Страница 8: ...ed guidelines for flue sizing calculations are in the Eclipse Combustion Engineering Guide EFE 825 6 500 7 000 7 500 8 000 70 65 75 80 85 200 0 20 40 60 80 100 120 140 160 180 Effective Tube Length in Feet 61 0 6 12 18 24 31 37 43 49 55 Effective Tube Length in Meters 500 1 000 1 500 2 000 2 500 3 000 3 500 4 000 4 500 5 000 5 500 6 000 Heat Transfer To Tank Btu h x 1000 0 1 903 2 050 2 196 2 343 ...

Страница 9: ...form in the tube at start up or during long idling periods The higher the efficiency the more condensation will increase To prevent condensation corrosion from shortening tube life or disrupting burner operation provide a condensate drain at the exhaust and slope the immersion tube downward away from the burner Figure 3 4 Efficiencies less than 80 Figure 3 5 Efficiencies 80 or more Tube placement ...

Страница 10: ...me limits vary from country to country The time that a burner takes to ignite depends on the distance between the gas shut off valve and the burner the air gas ratio the gas flow at start conditions In the USA with a time of 15 seconds to ignition there should be sufficient time to ignite the burners It is possible however to have the low fire too low to ignite within the time limit Under these ci...

Страница 11: ...onditions The blower data is based on the International Standard Atmosphere ISA at Mean Sea Level MSL which means that it is valid for sea level 29 92 Hg 1 013 mbar 70ºF 21ºC The make up of the air is different above sea level or in a hot area The density of the air decreases and as a result the outlet pressure and the flow of the blower decrease An accurate description of these effects is in the ...

Страница 12: ...d d Calculate the final blower air flow requirement based on 15 excess air at high fire Vair 1 excess air x Vair stoichiometric 1 0 15 x 11 508 ft3 h 13 234 ft3 h For this example final blower air flow requirement is 13 234 scfh at 15 excess air NOTE It is common practice to add an additional 10 to the final blower air flow requirement as a safety margin 3 Find the blower model number and motor ho...

Страница 13: ...ion with other safety components as a minimum standard for main gas safety shut off systems Step 7 Main Gas Shut Off Valve Train Consult Eclipse Eclipse can help you design and obtain a main gas shut off valve train that complies with the current safety standards The shut off valve train must comply with all the local safety standards set by the authorities that have jurisdiction For details pleas...

Страница 14: ... 10 3 millimeter mm inch in 3 94 x 10 2 MJ Nm Btu ft standard 26 86 From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0 1 millimeter mm meter m 0 001 From To Multiply By actual cubic foot h acfh actual cubic meter h am h 2 832 x 10 2 standard cubic foot h scfh normal cubic meter h Nm h 2 629 x 10 2 degrees Fahrenheit F degrees Celsius C F...

Страница 15: ...uires pushing a button to transfer the contacts when the pressure set point is satisfied 610 I 354 Gas Cock Gas cocks are used to manually shut off the gas supply 710 Solenoid valve normally closed Solenoid valves are used to automatically shut off the gas supply on a bypass gas system or on small capacity burner systems 760 Manual Butterfly Valve Manual butterfly valves are used to balance the ai...

Страница 16: ...een the top of the ratio regulator and the air supply line The cap must stay on the ratio regulator after adjustment 742 CRS Valve A CRS valve is used in a high low time proportional control system to quickly open and close the air supply 744 Pressure Taps Pressure taps measure static pressure The schematics show the advised positions of the pressure taps Impulse Line The impulse line connects the...

Страница 17: ... 2016 Honeywell International Inc All rights reserved ...

Отзывы: