background image

- 3 - 

SPECIFICATIONS:  

Operating Temperature

: 14° to 131° F  /  -10° to 55° C 

Relative Humidity

:  5 to 93% (UL tested at 93%); non-condensing

  

 
TROUBLESHOOTING: 

 

 

TROUBLE* 

 

NORMAL 

Self-Test Failure

1

 

Alarm Relay 

Closed 

Open 

Red LED 

Off 

Flashing 

*TROUBLE CONDITIONS:

 

1

 Self-Test Failure conditions: 

  •  Microwave supervision failure:  The sensor is operating in PIR mode only. 
  •  PIR self-test failure:  The sensor is disabled. 
  •  Temperature compensation failure: The temperature compensation is disabled. 
Depending on the Trouble condition, take the following corrective actions: 
  •  Verify the power supply is sufficient (at least 9V at the sensor). 
  •  Cycle power to the sensor. 
  •  Walk test the sensor.             

If the Trouble condition does not clear, replace the sensor.

 

 
APPROVAL LISTINGS:  

  FCC part 15, Class B verified  

  IC ICES-003, Class B verified  

  UL 639  

  ULC S306-03  

  SIA-PIR-01 Passive Infrared detector standard features for false alarm immunity.  

Product must be tested at least once each year / Le fonctionnement du produit doit être vérifié au moins une fois par année /  
El producto debe ser probado al menos una vez al año / O produto deve ser testado pelo menos uma vez por ano 
All wiring must be in accordance with: the National Electrical Code (ANSI/NFPA70); the Canadian Electrical Code, Part I (where applicable); UL681, 
Standard for Installation and Classification of Burglar and Holdup Alarm Systems; ULC-S302, Standard for Installation and Classification of Burglar 
Alarm Systems for Financial and Commercial Premises, Safes and Vaults; ULC-S310, Standard for Installation and Classification of Residential Burglar 
Alarm Systems; local codes and the authorities having jurisdiction. 
The products are intended to be powered by a power-limited output of a UL/CUL Listed Burglar Alarm control unit, or via a Listed UL603/ULC-S318 
power-limited power supply that provides 4 hours of standby power. 
The sensor must be mounted indoors, within the protected premises, and on a wooden stud, solid wood or with a robust wall anchor. 

UL Notes

: All interconnecting devices must be UL listed.  The pet immunity feature has not been evaluated by UL. 

 

 
 

FEDERAL COMMUNICATIONS COMMISSION STATEMENTS 

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. 
Unauthorized changes or modifications could void the user's authority to operate the equipment. 

CLASS B DIGITAL DEVICE STATEMENT 

This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your 
information: 
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the 
manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for 
a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection 
against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If 
this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following measures: 
•   Reorient the receiving antenna until interference is reduced or eliminated. 
•   Move the radio or television receiver away from the receiver/control. 
•   Move the antenna leads away from any wire runs to the receiver/control. 
•   Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. 
•   Consult the dealer or an experienced radio/TV technician for help. 

INDUSTRY CANADA CLASS B STATEMENT 

This Class B digital apparatus complies with Canadian ICES-003. 
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. 

FCC / IC STATEMENT 

This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This 
device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause 
undesired operation. 

Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux 
conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris 
les interférences causant une réception indésirable. 

 

Содержание DT8035 DUAL TEC

Страница 1: ... mm x 25 mm A A B B B X 4 MW SENSITIVITY MAX MIN LOOKDOWN ON OFF MIN MAX MW LED PI ON OFF DT8035 Enabled Activé Habilitado Habilitado Disabled Désactivé Deshabilitado Deshabilitado ON OFF Pet Immunity Insensibilité aux animaux Tolerancia a mascotas Pet Imunidade Microwave Range Adjustment Réglage de la portée des micro ondes Ajuste del rango de detección Microondas Ajuste de Alcance Microondas Fac...

Страница 2: ... the LED and enters normal operation mode For an additional 10 minute walk test enable walk test mode again with the flashlight feature see Walk Test Reset above Note During power up and walk test modes the LED is active regardless of the LED Enable Disable DIP switch setting 7 PLAN VIEW ALL ZONES A B C D 7 5ft 2 3m 0ft 0m 7ft 2m 13ft 4m 20ft 6m 27ft 8m 33ft 10m 40ft 12m 13ft 4m 0ft 0m 7ft 2m 13ft...

Страница 3: ...orized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use The FCC requires the following statement for your information This equipment generates and uses radio frequency energy and if ...

Страница 4: ...le représentant autorisé de Honeywell de votre région Por favor contacte con su distribuidor Honeywell Security para información sobre la garantía del producto Contacte o representante autorizado Honeywell local para obter informações relativas a garantia 2013 Honeywell International Inc Honeywell and DUAL TEC are registered trademarks of Honeywell International Inc All other trademarks are the pr...

Отзывы: