DS05 DIAL SET PRESSURE REGULATING VALVE
62-3041—2
6
TROUBLESHOOTING
Table 2 provides a troubleshooting guide for the DS05 Dial Set Pressure Regulating Valve.
Table 2. Troubleshooting the DS05 Dial Set Pressure Regulating Valve.
Problem
Solution
Whistling noise.
•
Slightly increase or decrease the outlet pressure until the noise disappears.
Will not hold pressure.
•
Clean the filter cartridge as described in the Installation section.
Chatters.
•
Replace the screen and O-rings.
•
Replace the cartridge as shown in Fig. 3.
Freezes up.
•
Replace bonnet or cartridge if damaged.
•
To avoid future freeze-up:
— Temporarily (slightly) open a downstream faucet if the DS05 will be exposed
to temperatures below 32°F (0°C). The slight water flow will eliminate
freeze-up.
— Move the DS05 to a location with an ambient temperature above 32°F (0°C)
If it is currently exposed to prolonged temperatures below 32°F (0°C).
Pressure gauge measures a lower
pressure under flow conditions than
was originally set during static
conditions.
•
DS05 is functioning properly. No action is necessary. The pressure decrease is
characteristic of all direct acting pressure regulating valves and is referred to as
falloff.