Honeywell DirectConnect AMX300 Скачать руководство пользователя страница 4

AMX300 DIRECTCONNECT™ MIXING VALVE KITS

62-3113—01

4

INSTALLATION

1.

Plastic thread protectors are installed in both ends of 

the flexible metal connector. Remove these protectors 

with pliers using a pulling and twisting motion, as shown 

in Fig. 4.

CAUTION

Do not damage the flared connectors or threads of 

the flexible metal connector when removing thread 

protectors.

Fig. 4. Remove plastic thread protectors.

2.

Install the cold water tee onto the water heater's cold 

water inlet. If installing on a water heater with 1-in. inlet 

fitting, use 1-in. FNPT to 3/4-in. MNPT brass reducer 

bushing and brass nipples. Tighten until leak tight and 

facing the front of the water heater as shown in Fig. 5.

Fig. 5. Install cold water tee.

3.

Install the AMX300 mixing valve onto the water heater's 

hot water outlet. If installing on a water heater with 1-in. 

outlet fitting, use 1-in. FNPT to 3/4-in. MNPT brass 

reducer bushing and brass nipples. Tighten until leak 

tight and facing the front of the water heater as shown in 

Fig. 6.

Fig. 6. Install mixing valve.

4.

Install the flexible metal connector to the AMX300 mix-

ing valve and cold water tee as shown in Fig. 7. Tighten 

flare connectors until leak tight. At this time the mixing 

valve kit should be leak tight.

Fig. 7. Install flexible connector.

Continue installation of potable water system as indicated in 

the installation and operation instruction manual supplied with 

the water heater. Once potable water system has been 

completely installed, and all connections are lead tight, attach 

the thermostrip to the mixed water outlet pipe no more than 10 

in. from the outlet of the AMX300 mixing valve.

TEMPERATURE ADJUSTMENT

Prior to adjusting the hand wheel setting on the mixing valve, 

the water heater must be operational and deliver hot water 

within the water heater outlet temperature range, typically 

100°F–180°F (38°C–82°C). To achieve the desired mixed 

water supply temperature, the temperature setting on the 

water heater may need to be adjusted. Prior to measuring the 

mixed water supply temperature, using the supplied 

M29788

FLEXIBLE 

METAL

CONNECTOR

FLARE 

CONNECTORS

WITH THREAD 

PROTECTORS

FRONT

HOT

COLD

EXTERNAL FITTING

INLET (COLD)

 

M29697

DIRECTLY TOWARD FRONT

OF THE WATER HEATER

BACK

FRONT

HOT

COLD

EXTERNAL FITTING

OUTLET (HOT)

 

M29699

DIRECTLY TOWARD FRONT

OF THE WATER HEATER

BACK

HOT

COLD

M29698A

FLEXIBLE

CONNECTOR

Содержание DirectConnect AMX300

Страница 1: ...us injury GETTING STARTED CAUTION For the homeowner s comfort safety and convenience it is recommended this mixing valve kit be installed and serviced by a plumbing professional These instructions provide detailed instructions for installation and maintenance of the mixing valve kit You must read these instructions carefully and completely to ensure proper installation Safety Precautions WARNING W...

Страница 2: ...ternal components causing it to not regulate the mixed water temperature properly If using sweat fittings to connect the mixing valve kit to the plumbing system DO NOT apply heat to the mixing valve after it is connected to the water heater Sweat the copper tubing of the plumbing system to the threaded adapter before connecting the adapter to the mixing valve 4 The valve MUST NOT be allowed to fre...

Страница 3: ...ixtures refer to literature 62 3112 AMX300 Series DirectConnect Mixing Valve Installation Instructions Refer to Fig 2 and 3 for descriptions and locations of the inlet and outlet ports on the mixing valve and cold water tee Fig 2 Mixing valve connections Fig 3 Cold water tee connections WARNING Do not return recirculation loop to any other location other than R inlet of the mixing device If recirc...

Страница 4: ...the AMX300 mix ing valve and cold water tee as shown in Fig 7 Tighten flare connectors until leak tight At this time the mixing valve kit should be leak tight Fig 7 Install flexible connector Continue installation of potable water system as indicated in the installation and operation instruction manual supplied with the water heater Once potable water system has been completely installed and all c...

Страница 5: ...re quickly with high water hardness and higher temperature of the water stored in the tank Cleaning the internal parts will usually restore the valve operating conditions In some cases it may be necessary to replace the thermostatic element assembly See Fig 10 A Thermostatic Element Replacement Kit AM 1 025RP is available through Honeywell distributors To remove scale from the internal surfaces of...

Страница 6: ...xing valve kit due to seasonal temperature variations in the cold water supply Fig 10 Exploded view of AMX300 Mixing Valve M31029 VALVE BODY PLUG SPRING AQUAMIX 1 THERMAL ELEMENT PLASTIC SPOOL HANDWHEEL FLAT SHOULDER SCREW SPRING SPINDLE ASSY O RING DIFFUSER CONTENTS OF THERMOSTATIC ELEMENT REPLACEMENT KIT AM 1 025RP ...

Страница 7: ...AMX300 DIRECTCONNECT MIXING VALVE KITS 7 62 3113 01 Replacement Parts Rebuild kit for AMX300 mixing valve AM 1 025RP Thermostrips in packs of 10 TS205 064 ...

Страница 8: ... Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 Honeywell Limited Honeywell Limitée 35 Dynamic Drive Toronto Ontario M1V 4Z9 customer honeywell com U S Registered Trademark 2010 Honeywell International Inc 62 3113 01 M S 01 10 Printed in U S A ...

Отзывы: