Honeywell DirectConnect AMX300 Скачать руководство пользователя страница 1

INSTALLATION INSTRUCTIONS

62-3113-01

AMX300 DirectConnect™ 

Mixing Valve Kits

Included in this box (see Fig. 1)

1.

AMX300 thermostatic mixing valve (“A”)

2.

Cold water tee (“B”)

3.

Flexible metal connector (“C”)

4.

Thermostrip (“D”)

5.

AMX300 Mixing Valve Installation Instructions

 (literature # 62-3112)

6.

AMX300 Mixing Valve Kit Installation Instructions

 (literature # 62-3113)

Fig. 1. Mixing valve kit contents.

Tools needed (not supplied)

1.

Wrench

2.

Pliers

Safety Definitions

These safety terms identify information you must read.

CAUTION

Indicates a hazardous situation which, if not 

avoided, could cause bodily injury or property 

damage.

WARNING

Indicates a hazardous situation which, if not 

avoided, could result in death or serious injury.

GETTING STARTED

CAUTION

For the homeowner's comfort, safety and 

convenience, it is recommended this mixing valve 

kit be installed and serviced by a plumbing 

professional.

These instructions provide detailed instructions for 

installation and maintenance of the mixing valve kit. 

You must read these instructions carefully and 

completely to ensure proper installation.

Safety Precautions

WARNING

Water inside the water heater is very hot and 

presents a scalding hazard.

Water temperatures in excess of 125 ºF (52 ºC) can 

cause severe burns. Explain this to homeowner and 

emphasize the risks associated with adjusting the 

mixing valve settings.

A

B

C

D

M29694A

Thermostrip

Accuracy expires after MMMYYYY

110

43

112

44

114

46

116

47

118

48

120

49

122

50

124

51

126

52

128

53

130

54

132

55

134

56

136

57

138

58

140

60

ºF ºc

CLICK ANYWHERE on THIS PAGE to RETURN to ANTI-SCALD PROTECTION
GUIDES at InspectApedia.com

Содержание DirectConnect AMX300

Страница 1: ...us injury GETTING STARTED CAUTION For the homeowner s comfort safety and convenience it is recommended this mixing valve kit be installed and serviced by a plumbing professional These instructions provide detailed instructions for installation and maintenance of the mixing valve kit You must read these instructions carefully and completely to ensure proper installation Safety Precautions WARNING W...

Страница 2: ...ternal components causing it to not regulate the mixed water temperature properly If using sweat fittings to connect the mixing valve kit to the plumbing system DO NOT apply heat to the mixing valve after it is connected to the water heater Sweat the copper tubing of the plumbing system to the threaded adapter before connecting the adapter to the mixing valve 4 The valve MUST NOT be allowed to fre...

Страница 3: ...ixtures refer to literature 62 3112 AMX300 Series DirectConnect Mixing Valve Installation Instructions Refer to Fig 2 and 3 for descriptions and locations of the inlet and outlet ports on the mixing valve and cold water tee Fig 2 Mixing valve connections Fig 3 Cold water tee connections WARNING Do not return recirculation loop to any other location other than R inlet of the mixing device If recirc...

Страница 4: ...the AMX300 mix ing valve and cold water tee as shown in Fig 7 Tighten flare connectors until leak tight At this time the mixing valve kit should be leak tight Fig 7 Install flexible connector Continue installation of potable water system as indicated in the installation and operation instruction manual supplied with the water heater Once potable water system has been completely installed and all c...

Страница 5: ...re quickly with high water hardness and higher temperature of the water stored in the tank Cleaning the internal parts will usually restore the valve operating conditions In some cases it may be necessary to replace the thermostatic element assembly See Fig 10 A Thermostatic Element Replacement Kit AM 1 025RP is available through Honeywell distributors To remove scale from the internal surfaces of...

Страница 6: ...xing valve kit due to seasonal temperature variations in the cold water supply Fig 10 Exploded view of AMX300 Mixing Valve M31029 VALVE BODY PLUG SPRING AQUAMIX 1 THERMAL ELEMENT PLASTIC SPOOL HANDWHEEL FLAT SHOULDER SCREW SPRING SPINDLE ASSY O RING DIFFUSER CONTENTS OF THERMOSTATIC ELEMENT REPLACEMENT KIT AM 1 025RP ...

Страница 7: ...AMX300 DIRECTCONNECT MIXING VALVE KITS 7 62 3113 01 Replacement Parts Rebuild kit for AMX300 mixing valve AM 1 025RP Thermostrips in packs of 10 TS205 064 ...

Страница 8: ... Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 Honeywell Limited Honeywell Limitée 35 Dynamic Drive Toronto Ontario M1V 4Z9 customer honeywell com U S Registered Trademark 2010 Honeywell International Inc 62 3113 01 M S 01 10 Printed in U S A ...

Отзывы: