DHC 23
OPERATION BY THE USER
7
■■
Select temperatures
Select room temperature
The setpoint for the room temperature can be set with the aid of the room temperature
knob between 8°C and 32°C.
The room setpoint can also be set with the remote control TF 26.
In the
normal operating mode
, the set room temperature is maintained during the
set heating times, in the
continuous heating mode
constantly.
If you want to heat outside the set heating times, you must set the operating mode
switch to
.
If you do not want to heat within the set heating times, you must set the operating mode
switch to
or
.
Select domestic hot water temperature
Warning:
With domestic hot water temperatures above 60°C there is danger of scalding at
all domestic hot water taps (kitchen, bathroom ...). You must then mix cold water
sufficiently.
The domestic hot water temperature can be set with the aid of the domestic hot water
temperature knob between 35°C and 75°C.
The set setpoint is always the cut-in value. The domestic hot water charging is
completed after reaching a switching difference (+ 5 K).
In the
normal mode, continuous heating mode
and
domestic hot water rea-
diness modes
, this temperature is controlled during the set times of domestic hot
water readiness, domestic hot water heating is switched off in between.
If you want to have domestic hot water at other times (e.g. early in the morning), you
must change the times of domestic hot water readiness (see
Adjustment by the
user
chapter).
⁄
!