COMFORTPOINT PROGRAMMABLE LON, VAV/UNITARY CONTROLLERS

62-0288—03

2

SPECIFICATIONS

General Specifications

Rated Voltage:

 20–30 Vac; 50/60 Hz

Power Consumption:

 

100 VA for controller and all connected loads (including the 

actuator on models CP-VL0000AS, CP-VL4022AS, and 

CP-VL6436AS)

Controller Only Load: 

20 VA maximum; models 

CP-UL1012S, CP-UL4024S, CP-UL6438S, 

CP-VL4024NS, and CP-VL6438NS. 

Controller and Actuator Load:

 21 VA maximum; models 

CP-VL0000AS, CP-VL4022AS, and CP-VL6436AS 

External Sensors Power Output:

 20 Vdc ±10% @ 75 mA 

maximum

VAV Operating & Storage Temperature Ambient Rating 

(models CP-VL0000AS, CP-VL4022AS, CP-VL4024NS, 

CP-VL6436AS, and CP-VL6438NS):

Minimum 32 F (0 C); Maximum 122 F (50 C)

Unitary Operating & Storage Temperature Ambient Rating 

(models CP-UL1012S, CP-UL4024S, and CP-UL6438S):

Minimum -40 F (-40 C); Maximum 150 F (65.5 C)

Relative Humidity:

 5% to 95% non-condensing

LED: 

Provides status for normal operation, controller down-

load process, alarms, manual mode, and error conditions

BEFORE INSTALLATION

The controller is available in eight models (see Table 1).

Review the power, input, and output specifications on page 2 

before installing the controller.

— Hardware driven by Triac outputs must have a minimum 

current draw, when energized, of 25 mA and a maximum 

current draw of 500 mA.

— Hardware driven by the analog current outputs must have 

a maximum resistance of 550 Ohms, resulting in a 

maximum voltage of 11 volts when driven at 20 mA.

If resistance exceeds 550 Ohms, voltages up to 18 Vdc are 

possible at the analog output terminal.

WARNING

Electrical Shock Hazard.

Can cause severe injury, death or property 

damage.

Disconnect power supply before beginning wiring or 

making wiring connections to prevent electrical shock 

or equipment damage.

INSTALLATION

The controller must be mounted in a position that allows 

clearance for wiring, servicing, removal, connection of the 

LonWorks® Bus Jack, and access to the Neuron® Service 

Pin.

The controller may be mounted in any orientation.

IMPORTANT

Avoid mounting in areas where acid fumes or other 

deteriorating vapors can attack the metal parts of the 

controller, or in areas where escaping gas or other 

explosive vapors are present. See Fig. 4–Fig. 7 on 

page 4 for mounting dimensions.

For CP-VL0000AS, CP-VL4022AS, and CP-VL6436AS 

models, the actuator is mounted first and then the controller is 

mounted. For the other models, go to “Mount Controller” on 

page 4 to begin the installation.

Mount Actuator onto Damper Shaft 

(CP-VL0000AS, CP-VL4022AS, and 

CP-VL6436AS)

The CP-VL0000AS, CP-VL4022AS, and CP-VL6436AS 

controllers include the direct-coupled actuator with Declutch 

mechanism, which is shipped hard-wired to the controller.

The actuator mounts directly onto the VAV box damper shaft 

and has up to 44 lb-in. (5 Nm) torque, 90-degree stroke, and 

90 second timing at 60 Hz. The actuator is suitable for 

mounting onto a 3/8 to 1/2 in. (10 to 13 mm) square or round 

VAV box damper shaft. The minimum VAV box damper shaft 

length is 1-9/16 in. (40 mm).

The two mechanical end-limit set screws control the amount 

of rotation from 12° to 95°. These set screws must be securely 

fastened in place. To ensure tight closing of the damper, the 

shaft adapter has a total rotation stroke of 95° (see Fig. 1).

NOTE: The actuator is shipped with the mechanical end-limit 

set screws set to 95 degrees of rotation. Adjust the 

two set screws closer together to reduce the rotation 

travel. Each “hash mark” indicator on the bracket 

represents approximately 6.5° of rotation per side.

NOTE: The Declutch button, when pressed, allows you to 

rotate the universal shaft adapter (see Fig. 1).

IMPORTANT

Determine the damper rotation and opening angle 

prior to installation. See Fig. 2 and Fig. 3 on page 3 

for examples.

 

Fig. 1. Series 60 Floating Actuator.

IMPORTANT

Mount actuator flush with damper housing or add a 

spacer between the actuator mounting surface and 

damper box housing.

UNIVERSAL SHAFT

CLAMPING BOLTS (2)

M23568

UNIVERSAL

SHAFT ADAPTER

MECHANICAL

END LIMIT SET

SCREWS (2)

DECLUTCH

BUTTON

Содержание CP-UL1012S

Страница 1: ...mmunica tions Each controller has flexible universal inputs for external sensors digital inputs and a combination of analog and digital Triac outputs The eight models are described in Table 1 The photo to the left is the model CP VL6436AS which includes the actuator Table 1 Controller configurations a One Universal Input UI 1 is user selectable as a fast digital pulse meter Each controller communi...

Страница 2: ...nd access to the Neuron Service Pin The controller may be mounted in any orientation IMPORTANT Avoid mounting in areas where acid fumes or other deteriorating vapors can attack the metal parts of the controller or in areas where escaping gas or other explosive vapors are present See Fig 4 Fig 7 on page 4 for mounting dimensions For CP VL0000AS CP VL4022AS and CP VL6436AS models the actuator is mou...

Страница 3: ...0 degrees a Manually open the damper fully rotate clockwise b The actuator is shipped with the mechanical end limits set at 95 degrees Adjust the two mechanical end limit set screws to provide the desired amount of rotation Adjust the two set screws closer together to reduce the rotation travel c Tighten the two mechanical end limit screws Phillips 2 screwdriver 26 5 31 lb in 3 0 3 5 Nm torque d U...

Страница 4: ...ATION PANEL MOUNTING HOLE 4X 3 16 IN 4 5 M28647 5 3 64 128 8 5 16 211 6 29 64 164 1 55 64 47 6 17 64 159 7 16 11 DEPTH IS 2 1 4 57 M28649 NOTE CONTROLLER CAN BE MOUNTED IN ANY ORIENTATION 3 16 4 5 PANEL MOUNTING HOLE 4X 1 1 1 1 1 1 1 2 2 2 2 2 3 4 5 6 7 8 9 0 1 2 3 4 1 1 1 1 1 1 1 2 2 2 2 2 3 4 5 6 7 8 9 0 1 2 3 4 1 1 1 2 3 4 5 6 7 8 9 0 1 2 1 1 1 2 3 4 5 6 7 8 9 0 1 2 DEPTH IS 2 1 4 57 4 13 16 12...

Страница 5: ...CP VL0000AS CP VL4022AS CP VL4024NS CP VL6436AS and CP VL6438NS Air flow Pickup For CP VL0000AS CP VL4022AS CP VL4024NS CP VL6436AS and CP VL6438NS connect the air flow pickup to the two restrictor ports on the controller see Fig 9 NOTES Use 1 4 inch 6 mm outside diameter with a 0 040 in 1 mm wall thickness plenum rated 1219 FR 94V 2 tubing Always use a fresh cut on the end of the tubing that conn...

Страница 6: ...removing connections from the 24 Vac power 24 Vac 24 Vac COM earth ground EGND and 20 Vdc power 20 Vdc terminals IMPORTANT Use the heaviest gauge wire available up to 14 AWG 2 0 sq mm with a minimum of 18 AWG 1 0 sq mm for all power and earth ground wiring Screw type terminal blocks are designed to accept up to one 14 AWG 2 0 sq mm conductor or up to two 18 AWG 1 0 sq mm conductors More than two w...

Страница 7: ...res to 3 16 in 5 mm before inserting them into the terminal and tightening the screw 5 Pull on each wire in all terminals to check for good mechanical connection Fig 13 Attaching two or more wires at terminal blocks Controller Replacement CP VL0000AS CP VL4022AS and CP VL6436AS For CP VL0000AS CP VL4022AS and CP VL6436AS controllers which are hard wired to an actuator perform the following actions...

Страница 8: ...ler from its mounting IMPORTANT FOR CONTROLLERS MOUNTED TO A DIN RAIL 1 Push straight up from the bottom to release the top pins 2 Rotate the top of the controller outwards to release the bottom flex connectors see Fig 8 on page 5 5 Mount the new controller see Installation on page 2 6 Reconnect the two air flow pickup tubes to the pressure sensor see Piping CP VL0000AS CP VL4022AS CP VL4024NS CP ...

Отзывы: