background image

CM921

 CHRONOTHERM

 

 


EN0H 8557 UK07 R0 09/06 

 
 
 

SPECIFICATIONS 

CONTROLS/DISPLAY LAYOUT

 

ELECTRICAL

 

Room unit power 
supply 

:

  2 x 1.5 V IEC LR6 (AA) Alkaline cells 

Battery life 

:

  Minimum 2 years   

Battery 
replacement 

:

  Program retained in EEPROM 

Receiver power 
supply 

:

  230V AC +10% - 15%, 50Hz 

Switch type 

:

  SPDT potential free 

Output rating 

:

  24-230 V AC, 10 A resistive, 3 A inductive 

0.6 p.f.   

Wiring (receiver 
only) 

:

  Cable terminals for mains and relay wiring 

for max 2.5 mm

2

 wire 

Wire access 

:

  from the rear (wall box mounting), right 

and bottom 

RF 

RF operation band 

:

  ISM (868.0-868.6) MHz, 1% duty cycle 

RF communication 
range 

:

  30 m in a residential building environment 

RF communication 
technology 

:

  short, high rate transmissions to minimise 

air time and avoid collisions 

Blocking immunity 

:

  Receiver class 2 (ETSI EN300 220-1 

version 1.3.1) 

RF binding method 

:

  Factory pre-bound with the room unit.  

ENVIRONMENTAL & STANDARDS 

Operating 
temperature 

:

  0 to 40

o

C when relay load <  8 A 

:

  0 to 30

o

C when relay load > 8 A 

Shipping & storage 
temperature 

:

  -20 to 55

o

Humidity 

:

  Humidity range 10 to 90% rh, non-

condensing 

IP class 

:

 30 

Meeting the 
following 
standards 

:

  EN60730-1(Nov 2000), EN55014-1(1997), 

EN55014-2(2000), ETSI EN300 220-3 
(2000), ETSI EN301 489-3(2000) 

TEMPERATURE CONTROL 

Sensing element

:

  100K (@ 25

 o

C ) NTC thermistor 

Control form 

:

  Fuzzy Logic Algorithm 

Minimum ON 
time 

10% of cycle time (min one minute), 
adjustable to 2 to 5 min (see installer set 
up)

 

Cycle rate 

:

  Selectable by application (see installer 

set up) 

Temperature 
control accuracy 

:

 

+

0.5 K (nominal) @ 20

o

C, 50% load 3K 

Δ

/hour  

Fail-safe mode 

:

  Off or cycling depending on the CM927 

system set-up 

TIME SETTING/PROGRAMMING 

Time display 

:

  24 hour or 12 hour AM/PM format 

Time keeping 
accuracy 

:

  Typically better than 10 minutes per year 

Program  

:

  1-day with 6 daily time and temperature 

level changes 

Time setting 
resolution 

:

  Time of day - 1 minute                 

Program – 10 minute steps 

Temperature 
setting range 

:

  Program  : 5 to 35

o

C in 0.5 

o

C steps Frost 

 

     : 5

 o

C or equal to lower limit (5

 

o

C to 16

 o

C). Frost protection does not 

work in cooling mode 

Room 
Temperature 
display range 

:

 From 0

 o

C to 50

 o

C  

 

Room Unit Layout: 
 
1. 

Day & Date Display 

2. Time 

Display 

3. 

Dynamic Text Display 
(DTD) 

4. 

Burner On Indicator 

5. 

Battery Low Indicator 

6. Temperature 

Display 

7. Temperature 

Change 

Buttons 

8. Information 

Enquiry 

Button 

9. Slider 

Switch 

10. 

Green OK Button 

11. Program 

Buttons 

12. Battery 

Cover 

13. Battery 

Compartment 

14. Holiday 

Button 

15. 

Time Change Buttons 

Содержание CM921

Страница 1: ...minate the display for easier viewing in low light conditions Reliable RF communication utilising 868 MHz band with 1 duty cycle limit to minimise communication disturbance Every room unit can be bound with several relay boxes e g to control several electric heating panels Armchair programmed Holiday button that provides energy savings by reducing to a constant temperature for 1 to 99 days when pe...

Страница 2: ...ds EN60730 1 Nov 2000 EN55014 1 1997 EN55014 2 2000 ETSI EN300 220 3 2000 ETSI EN301 489 3 2000 TEMPERATURE CONTROL Sensing element 100K 25 o C NTC thermistor Control form Fuzzy Logic Algorithm Minimum ON time 10 of cycle time min one minute adjustable to 2 to 5 min see installer set up Cycle rate Selectable by application see installer set up Temperature control accuracy 0 5 K nominal 20 o C 50 l...

Страница 3: ...itions Abbreviated Set Up Description e g Cl Clock Format Factory Setting or New Choice Press TEMP or to change e g 12 AM PM Format 24 24hr Format Installer Set up Number Press or to change e g 1 Clock Format Brief Description of the Parameter Function Specific Applications Setting What do you need to change Cycle Hour Minimum ON time in minutes Note All parameters listed below belong to category ...

Страница 4: ...f 5 C can be increased up to 21 C to protect inhabitants from cold Set parameter 6 uL category 1 to the desired upper limit Set parameter 7 LL category 1 Parameter Installer Set Up Number Abbreviation Press or keys to select Factory Setting Optional Setting Category 1 Parameters Room Thermostat Settings Display Description Display Description AM PM 24hr Display 1 Cl 24 24 hr clock display 12 12 hr...

Страница 5: ...Off 1 Relay 20 on 80 off The following parameters are for the control of other Honeywell Wireless products such as Wireless Underfloor Heating controls and Wireless Radiator controls For more information please contact Honeywell sales Room Temperature Sensor Use 8 Su 0 HC60 Control 1 2 3 or 4 1 HR80 HM80 control with own remote sensor no temperature displayed 2 Hr80 HM80 HCE80 control with CM Sens...

Страница 6: ...oles IMPORTANT 1 The installer must be a trained service engineer 2 Disconnect the power supply before beginning installation INSTALLATION The CM921 is a radio frequency device and for the best performance should be installed in an open space Leave at least 30cm distance from any metal objects including wall boxes and at least 1 metre from any other electrical equipment e g radio TV PC etc Do not ...

Страница 7: ...em pack includes HC60 1 day RF system pack includes HC60 1 day RF system pack includes HC60 1 day room unit spare 1 day room unit spare 1 day room unit spare HC60 Spare HC60 Spare HC60 Spare CMT921A1018 CMT921A1026 CMT921A1042 CMS921B1018 CMS921B1026 CMS921B1042 R6660D1017 R6660D1025 R6660D1041 Honeywell Honeywell Honeywell Honeywell Honeywell Honeywell Honeywell Honeywell Honeywell French Dutch F...