Honeywell Chronotherm modulation Скачать руководство пользователя страница 6

Symptom

Blank display

The energy meter and
radiator symbol are on,
but radiators are still cold

At the programmed time
the temperature is too
high or too low
comparing with
programmed values

Change of  temperature
level at the wrong time

Temperature too high or
too low

Display shows day, time
and 

 symbol

Display shows only 
symbol and spanner

 every 5 sec.

Currently displayed
segments and spanner
symbol are flashing

Possible Cause

No power from the boiler

Mains power loss lasting
more then 8 hours

Wired connection
between the boiler and
the thermostat broken

Boiler not operating

Inertia of the heating
system

Adaptive Intelligent
Recovery action

Adaptive Intelligent
Recovery action

Temperature level set
incorrectly

Thermostat is powered
but receives no
information from the boiler

There is a short or open
circuit between the boiler
and thermostat.

Boiler is in lockout
condition (NOTE:
Pressing the I you can
read the fault code
transmitted by the boiler.
The fault code depends
on the boiler type – refer
to the boiler User Manual
for more information)

 OPERATING YOUR THERMOSTAT (CONTINUED)

I’m planning to go out for the weekend. I would like to save energy when I
am away but I would like to be sure that my house would be at comfortable
temperature on Sunday at 17:00.

1. Follow the same procedure as described above to select number of days you

will be away.

2. Press the 

 (HOLIDAY) button a second time to display the holiday return

time. (The time displayed is current time + 1 hour rounded off to 30 minutes)
The return time can be adjusted using the 

 + or – button in 30 minutes steps.

3. At the programmed return time the thermostat will return to the normal control

as set by the slider position.

I’m having some friends round for party. How can I extend my heating
program for a few hours?

1. Press the 

 (HOLIDAY) button twice to display the time when you would like to

switch the heating off. (The time displayed is current time + 1 hour rounded off
to 30 minutes) The return time can be adjusted using the 

 + or – button in 30

minutes steps.

2. Adjust your room temperature using 

TEMP

erature 

 or 

 button

3. The thermostat will maintain the set temperature level until specified time. At

the programmed time it will return to the normal control as set by the slider
position.

How can I restore the factory program setting?

The factory program is restored when the 

RESET 

key located at the back of the

thermostat is pressed.

NOTE: Before removing the thermostat from the wall review the section

MAINTAINING YOUR THERMOSTAT

 MAINTAINING YOUR THERMOSTAT

Chronotherm Modulation is made from high quality plastics and does not require
special maintenance if used under normal operational conditions.

In case you have to remove your thermostat temporarily for purpose of wall
decoration or alterations follow the guidelines below.

Remove the thermostat from the wall plate

1. Switch off the electrical supply of the thermostat by isolating the heating

system.

2. Remove the thermostat by pressing the plastic lid with a screwdriver and gently

pushing it up. This will loosen the thermostat from its wall plate

3. Always protect the contacts in the wall plate from paint or other substances

 TROUBLE - SHOOTING GUIDE

Chronotherm Modulation is able to provide you with fault diagnostic information.
Please note that the type of data sent from the boiler determines the way the
boiler faults are displayed. Review the boiler user manual for more information.

 YOUR  INDIVIDUAL TEMPERATURE  PROGRAM

You can use the tables below to record your weekly temperature profile. Please
note that period 1 must always be programmed.

MONDAY

Program

1

2

3

4

5

6

Time

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

Temperature

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

TUESDAY

Program

1

2

3

4

5

6

Time

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

Temperature

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

WEDNESDAY

Program

1

2

3

4

5

6

Time

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

Temperature

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

THURSDAY

Program

1

2

3

4

5

6

Time

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

Temperature

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

FRIDAY

Program

1

2

3

4

5

6

Time

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

Temperature

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

SATURDAY

Program

1

2

3

4

5

6

Time

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

Temperature

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

SUNDAY

Program

1

2

3

4

5

6

Time

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

_ _:_ _

Temperature

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

_ _°C

Reset key

IMPORTANT!

- The wall plate terminals must not be connected to any other voltage

sources. Applying voltage to wall plate terminals can seriously damage your
heating boiler.

- Protect the electronic components from contact with any paint chemicals,

dust etc, that could cause damage to the thermostat

Mounting the thermostat on the wall plate

1. Check the wall plate and make sure that the contacts are clean and dry.

2. Hang the thermostat in the holes on top of the plate

3. Move the thermostat downwards and push it gently towards the wall until

thermostat locks into the wall plate

Remedy

Switch the boiler on

Restore power supply

Call installer to check the
wiring

Refer to the boiler User
Manual

Allow more time for the
system to heat up

This is normal behavior
of your thermostat after
installation. It takes a few
days before AIR function
will adjust itself to your
house

When the temperature
level changes upward the
thermostat will
automatically adjust the
temperature level to
reach the new required
level on time

Press the I button to
check the programmed
temperature level.
Re-program the unit if
necessary.

Call installer

Call installer to check the
wiring

Press the reset button to
restart the boiler. If the
symptom appears again
call installer immediately.

 

 

 

Содержание Chronotherm modulation

Страница 1: ...h you want to be warm and Chronotherm Modulation will then decide when to turn the heating on 1 Day button allows you to set correct day of the week 2 The display continuously shows information about time day of the week and temperature The Energy meter allows you to see the current firing rate of the boiler A radiator or tap symbol is shown when boiler is servicing central heating or domestic hot...

Страница 2: ... numbers 1 to 6 The start time and temperature level for each period is programmable within the temperature setting range of 5 to 30 C Backup during power supply failure Your Chronotherm Modulation operates without batteries The power is supplied through the communication connection In case of the mains power loss a rechargeable backup power supply is sufficient to keep the program and the clock s...

Страница 3: ...Sunday Période 1 2 3 4 5 6 Time 08 00 23 00 Temperature 19 C 15 C How do I set my own temperature program for each day of the week 1 Move the slider to PROGRAM position You will see the first temperature change time and temperature level for Monday s program the two small arrows are displayed only when the programmed temperature level is shown The flashing display indicates that you can make chang...

Страница 4: ...he slider to the MANUAL position Adjust the manual temperature by pressing the TEMPerature or button The manual temperature can be set anywhere from 5 C up to 30 C How can I switch the Chronotherm Modulation off Move the slider to the position Thermostat has built in frost protection feature so that if temperature will drop below 7 C it will automatically switch back on to prevent pipes from freez...

Страница 5: ...er position I m having some friends round for party How can I extend my heating program for a few hours 1 Press the HOLIDAY button twice to display the time when you would like to switch the heating off The time displayed is current time 1 hour rounded off to 30 minutes The return time can be adjusted using the or button in 30 minutes steps 2 Adjust your room temperature using TEMPerature or butto...

Страница 6: ...hing it up This will loosen the thermostat from its wall plate 3 Always protect the contacts in the wall plate from paint or other substances IMPORTANT The wall plate terminals must not be connected to any other voltage sources Applying voltage to wall plate terminals can seriously damage your heating boiler Protect the electronic components from contact with any paint chemicals dust etc that coul...

Страница 7: ...ram 1 2 3 4 5 6 Time _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Temperature _ _ C _ _ C _ _ C _ _ C _ _ C _ _ C THURSDAY Program 1 2 3 4 5 6 Time _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Temperature _ _ C _ _ C _ _ C _ _ C _ _ C _ _ C FRIDAY Program 1 2 3 4 5 6 Time _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Temperature _ _ C _ _ C _ _ C _ _ C _ _ C _ _ C SATURDAY Program 1 2 3 4 ...

Страница 8: ...the I you can read the fault code transmitted by the boiler The fault code depends on the boiler type refer to the boiler User Manual for more information TROUBLE SHOOTING GUIDE Chronotherm Modulation is able to provide you with fault diagnostic information Please note that the type of data sent from the boiler determines the way the boiler faults are displayed Review the boiler user manual for mo...

Отзывы: