42009636-005 R3
1
honeywell
Chronotherm
Parameters
Optimisation
Minimum ON Time
AM-PM / 24hr Display
Accessory Module Type
RESET Time / Temperature
Program
Heat / Cool Operation
Electric Heat
Pump Exercise
Cycle Rate
Second Temperature
Sensor
Upper Temperature Limit
Lower Temperature Limit
Temperature Offset
Pressure Offset
(needed for Weatherstation
accessory only)
Proportional Band Width
Return all Set-Up Features
to Factory Settings
Installer Set-Up Mode - Settings Table
You must now press the PROG 2 key to enter the next section
Installer Set-Up
Number /
Abbreviation
(Press + or -
key to change)
1:0P
2:0t
3:Cl
4:At
5:rP
6:HC
7:Eh
8:PE
9:Cr
10:SS
11:UL
12:LL
13:tO
14:PO
15:Pb
16:FS
Display
0
1
0
0
1
1
0
0
6
0
30
5
0
0
1.5
1
Factory Setting
Description
Optimisation disabled
1 minute minimum ON time
24 hr clock display
No accessory module
plugged in
Time / Temperature profile
set to factory default
Changes to 0 when one of the
time/temp profiles are changed
Heating Operation
Applications < 3A
Pump Exercise Disabled
6 cycles per hour (cph) for
gas boilers, zone valves and
fan-coil
No sensor fitted
30°C Upper Temp. Limit
5°C Lower Temp. Limit
No offset
No offset
1.5°C Proportional Band
All settings held are the
factory defaults. Changes to
0 when one of the parameter
values are changed
Display/Setting
1
2 to 5
1
1, 2
0
1
0
1
1
3, 9, 12
1, 2
21 to 29
6 to 16
-3 to +3
-99 to +99
1.6 to 3.0
0
1
Optional Setting
Description
Optimisation enabled
2 - 2 minutes
3 - 3 minutes
4 - 4 minutes
5 - 5 minutes
12 hr AM / PM clock display
1 - Auto Time Setting Module
2 - Weatherstation Module
Time / Temperature are as
programmed
To restore the factory profile
set to 1
Cooling Operation
Applications 3 - 8A
Pump Exercise Enabled
3 - 3 cph
9 - 9cph
12 - 12 cph
1 - Outside Temperature
Sensor fitted
2 -Remote Temp. Sensor fitted
21°C to 29°C adjustment in
1°C steps
6°C to 16°C adjustment in 1°C
steps
-3°C to +3°C adjustment in
0.1°C steps
-99 mbar to +99 mbar
adjustment in 1 mbar steps
1.6°C to 3.0°C adjustment in
0.1°C steps
Settings are as modified
above
To restore the factory profile
set to 1
Installer Set-Up
Category
(Press keys PROG 1
or 2 to select)
1 2
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
Notes
1) When the Installer Set-Up Mode is initiated, only Category 1 (
1) Set-Up Features
are accessible.
Category 2 (
2) Set-Up Features are accessed by pressing the PROG. 2 key.
2) Remember to always press the INFO button to confirm that you want to store your new
Installer Set-Up setting.
3) To exit the Installer Set-Up Mode move the slider to the AUTOmatic or MANual position.
2
3
4
a
4
b
4
c
5
6
1.0-2.5mm²
honeywell
Home Comfort & Systems
Honeywell Control Systems Ltd.
Newhouse Industrial Estate
Motherwell, ML1 5SB
Scotland
http://europe.hbc.honeywell.com
3mm
max.
3mm
max.
This product has been designed with your
environment in mind! Please respect this by
disposing of all packaging, used parts and
eventually the product itself in an environ-
mentally friendly manner.