level mark. Running the unit with inadequate water may cause pump failure. If ice is available you 
may add ice in the top compartment to enhance the cooling performance. 
 

1.7  CLEANING & MAINTENANCE 
 
Warning: 

 

Before  cleaning  the  unit,  switch  it  to  the  ''off''  position  and  remove  the  plug  from  the  power 
socket. 

 

To clean the outside, use a damp cloth to remove dirt and dust. 

 

Never use corrosive elements or any chemicals to clean this product. 

 

When the product is not in use, store the unit in a dry place out of direct sunlight. 

 

Draining and Cleaning the Water Tank:  

 

Turn the power “off” and disconnect the air cooler from the power 
supply. 

 

Move  the  unit  to  a  location  where  it  can  be  drained.  Remove  the 
rubber plug from the tank and allow the tank to empty. 

 

Once the tank is empty, unlock the latches on both sides and lift off 
the cooler top section as shown in the figure and place it vertically 
on the floor. 

 

Refill the water tank with clean water and drain it completely. 

 

Clean  the  water  tank  with  detergent  or  a  damp  cloth  and  rinse  it 
thoroughly. 

 

Place the unit top carefully on the tank and lock the latches. 

 

Refill the water tank with clean water, up to the maximum level. 

 

The  air  cooler  is  now  ready  to  be  used.  This  cleaning  process 
should be repeated weekly to maintain the integrity of the unit and 
to remove particles filtered from the air. 

 

Cleaning the Filter and Honeycomb: 

 

The appliance is supplied with carbon filter & honeycomb cooling media. 

 

Always keep the Carbon filter clean. You can wash the Carbon filter at least twice a  year or 
whenever you feel necessary. 

 

The  carbon  filter  and  honeycomb  media  are  located  inside  the  back  panel.  Open  the  back 
panel by using a star screw driver to clean or replace the carbon filter or honeycomb media. It 
is  recommended  that  the  carbon  filter  and  honeycomb  media  be  replaced  every  year, 
depending on use and environment. 

 

Draining  the  water  reservoir  and  refilling  with  fresh  water  at  least  once  a  week  will  greatly 
reduce mineral deposits in the pads and help to extend the life of Honeycomb cooling media. 

 

Do  not  run  the  unit  in  COOL  mode  with  stale  water  in  the  tank.  You  must  empty  the  water 
tank and refill with fresh water, especially if the tank has not been cleaned in a long time. 

 

The cleaning frequency for the Honeycomb media depends on local air and water conditions. 
In  areas  where  the  mineral  content  of  water  is  high,  mineral  deposits  may  build  up  on  the 
honeycomb cooling media and restrict air flow. Draining the water reservoir and refilling with 
fresh water at least once a week will help reduce mineral deposits. If mineral deposits remain 
on the Honeycomb media, the media should be removed and washed under fresh water. The 
media should be cleaned every two months or sooner, depending on your needs. 

 

For best results allow the  honeycomb cooling media to dry after each use by turning off the 
cool function 15 minutes before turning the unit off. 

Содержание CHL30XC

Страница 1: ...EVAPORATIVE AIR COOLER SERVICE MANUAL CAUTION Before servicing the unit read the Safety Precautions in this manual Only for authorized service MODEL NO CL30XC CHL30XC INDOOR USE ONLY ...

Страница 2: ...ng Media 2 2 How To Change Water Pump 2 2 1 Water Tank 2 2 2 Water Pump Wiring Connection 2 3 How To Change Main PCB Board 2 3 1 Top Panel 2 3 2 Main PCB Board Wiring Connection 2 3 3 Wiring Color Connection 2 4 How To Change Main Motor 2 4 1 Blower Housing 2 4 2 Main Motor Wiring Connection 3 Troubleshooting Guide 3 1 Outside Dimensions 3 2 Cooling System 3 3 Troubleshooting Guide 4 Schematic Dia...

Страница 3: ...lead and each exposed metallic part on the equipment at all MODES except POWER OFF 4 The value should be over 1 MΩ 1 3 Specifications MODELS ITEMS CL30XC CHL30XC Power Supply 1Ø 220 240V 50Hz Input W 252W 2250W Running Current A 1 15A 10 23A Fan Type Blower Fan Speeds 4 3 Fan Motor HP 1 6 Operation Control Control Panel with Remote Control Relative Humidity Control Adjustable Air Direction Control...

Страница 4: ...g and check it is in good condition If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard DO NOT operate any product with a damaged cord or plug DO NOT use an extension cord with this appliance DO NOT run power cord under carpeting or cover with rugs or runners Arrange the cord away from areas where it may ...

Страница 5: ...onsible for their safety DO NOT let children play with any appliance packaging or plastic bags Injury may result from such practice Children should be supervised to ensure that they do not play with the appliance If the unit is damaged or it malfunctions do not continue to operate it Place the unit on the floor only This product is not intended for use in wet or damp locations Never locate the pro...

Страница 6: ...CONFIDENTIAL Website http www honeywellaircoolers com 6 Operations Control Panel For CL30XC Icons on LCD Control Panel For CHL30XC Icons on LED ...

Страница 7: ...sol propellants from air SLEEP For CL30XC When sleep is selected airflow will randomly vary between High Medium and Low HEAT For CHL30XC Press the HEAT button to turn ON the heater You can vary the heater from LOW HEAT to HIGH HEAT Low and High HEAT is indicated on the control panel and it changes with the press of HEAT button When the heater is turned off by either depressing the HEAT button or P...

Страница 8: ...t two new AAA dry cell batteries Care must be taken to insert the batteries according to the correct polarity markings shown inside the battery compartment Always point the remote control signal transmitter towards the unit when operating Make sure that the signal path is not obstructed Remove the batteries if the unit is not going to be used for an extended period of time Do not drop the remote c...

Страница 9: ...d from the air Cleaning the Filter and Honeycomb The appliance is supplied with carbon filter honeycomb cooling media Always keep the Carbon filter clean You can wash the Carbon filter at least twice a year or whenever you feel necessary The carbon filter and honeycomb media are located inside the back panel Open the back panel by using a star screw driver to clean or replace the carbon filter or ...

Страница 10: ...ge Honeycomb Cooling Media 2 1 1 Rear Panel Use screw driver to remove 3 galvanized screw with plate head ST3 5 10 between the top panel and rear panel and then remove the 9 galvanized screw with plate head ST3 5 10 between the left and right panel and rear panel Remove the rear panel 2 1 2 Honeycomb Cooling Media Remove the pressing piece Remove the honeycomb cooling media from the top side ...

Страница 11: ... screw driver to remove 3 galvanized screw with plate head ST3 5 10 on the water pump box Remove the water pump box and remove the water tube Use screw driver to remove 2 galvanized screw with plate head ST3 5 10 of the wiring pressing piece C Use screw driver to remove 2 galvanized screw with plate head ST3 5 10 of the wiring pressing piece B 2 2 2 Water Pump Wiring Connection Remove the below 2 ...

Страница 12: ...lvanized screw with plate head ST3 5 10 between the left right panel and top panel Use screw driver to remove 2 galvanized screw with plate head ST3 5 10 of the wiring pressing piece A Use screw driver to remove 4 galvanized screw with plate head ST3 5 10 of the PCB board to get the PCB board 2 3 2 Main PCB Board Wiring Connection Unplug the wiring connection Unplug the wiring connection 2 3 3 Wir...

Страница 13: ... 9 galvanized screw with plate head ST3 5 15 to remove the blower housing Use hex nut spanner S 3 to remove retainer nut of the blower Use screw driver to remove 7 and 4 galvanized screw with plate head ST3 5 15 and ST3 5 10 to remove left right panel and blower housing Remove the wiring cap below picture shown Note connection is between capacitor and the motor Use screw driver to remove 8 galvani...

Страница 14: ... www honeywellaircoolers com 14 3 TROUBLESHOOTING GUIDE 3 1 Outside Dimensions Width 458 mm 18 0 Depth 352 mm 13 9 Height 856 mm 33 7 3 2 Cooling System 1 Body 2 Fan Blower 3 Water Tank 4 Water Pump 5 Water Pipe 6 Cooling Media ...

Страница 15: ...ise inside the product Noise of water pump when water not up to min water level Turn off the product Add water and then turn on the product again Motor or blower problem Turn off and unplug the product or change the main motor according to the procedure 2 4 Remote control not working Signal path is obstructed Clear signal path No battery or low battery in the remote control unit Check battery Must...

Страница 16: ...CONFIDENTIAL Website http www honeywellaircoolers com 16 4 SCHEMATIC DIAGRAM 4 1 Wiring Diagram For CL30XC For CHL30XC ...

Страница 17: ...n Motor 1 White High speed on main PCB 2 Yellow Medium speed on main PCB 3 Blue Low speed on main PCB 4 Black Neutral on main PCB 5 Red to capacitor by end closed connector 6 Brown to capacitor by end closed connector 7 Green Yellow Earth Ground Water Pump 1 Black on main PCB plug in type 2 White on main PCB plug in type Swing Motor 1 Yellow on main PCB 2 Yellow on main PCB ...

Страница 18: ...CONFIDENTIAL Website http www honeywellaircoolers com 18 4 3 Circuit Diagram ...

Страница 19: ...CONFIDENTIAL Website http www honeywellaircoolers com 19 4 4 Components Location For Main PCB Board ...

Страница 20: ...CONFIDENTIAL Website http www honeywellaircoolers com 20 5 EXPLODED VIEW ...

Страница 21: ...top cover screw base 3 20 ACP30A 02 02 ice compartment cover 1 21 ACP30A 21 16 PCB wiring assembly 1 22 ACP30A 02 03 00B IMD control panel 1 23 ACP30A 02 04 01 water flow regulator 1 24 ACP30A 02 04 02 water flow regulator knob 1 25 ACP30A 02 04 03 water flow regulator tube 2 26 ACP30A 03 01 left panel 1 27 ACP30A 03 02 latch 2 28 ACP30A 03 03 latch link 2 29 ACP30A 03 04 Long pin 2 30 ACP30A 03 0...

Страница 22: ...1 00 Tank assembly 1 66 ACP30A 21 27 Wire tie 1 67 ACP30A 12 02 05 Tank plug 1 70 ACP30A 12 03 front caster 2 71 ACP30A 12 04 rear caster 2 72 ACP30A 13 01 RC front cover 1 73 ACP30A 13 02 RC back cover 1 74 ACP30A 13 05 RC battery cover 1 75 ACP30A 13 06 cathode 1 76 ACP30A 13 07 anode 1 77 ACP30A 13 08 Connector 1 78 ACP30A 13 09 AAA battery 2 79 ACP30A 55 05 Pump 1 80 ACP30A 55 03 Motor 1 81 AC...

Отзывы: