Honeywell C7772A Скачать руководство пользователя страница 2

C7772A, F, G WALLPLATE TEMPERATURE SENSOR

68-0213-04

2

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the 

TRADELINE® Catalog or price sheets for complete ordering number.

If you have additional questions, need further information, or would like to comment on our products or services, please write or 

phone:

1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).

2. Honeywell Customer Care

1885 Douglas Drive North

Minneapolis, Minnesota 55422-4386

3. http://customer.honeywell.com or http://customer.honeywell.ca

International Sales and Service Offices in all principal cities of the world. Manufacturing in Belgium, Canada, China, Czech 

Republic, Germany, Hungary, Italy, Mexico, Netherlands, United Kingdom, and United States.

SPECIFICATIONS

Models: See Table 1.

Dimensions: See Fig. 1.

Temperature Ratings:

Operating: 45°F to 99°F (7°C to 37°C).

Shipping: -40°F to 150°F (-40°C to 65°C).

Long-term temperature sensor drift:

(for 20K ohm sensors only) 

Maximum sensor drift is nom/-0.13°F after 5 years of 

operation, no appreciable drift thereafter. No calibration of the 

device is possible. Long term drift calibration/maintenance 

through controller software is typically not necessary.

Humidity Ratings: 5 to 95% rh, non-condensing.

Approvals:

National Electrical Code (NEC) Class II.

Fig. 1. C7772 Dimensions in in. (mm).

INSTALLATION

When Installing this Product...

1. Read these instructions carefully. Failure to follow them 

could damage the product or cause a hazardous

condition.

2. Check the ratings given in the instructions and on the 

product to make sure the product is suitable for your 

application.

3. Installer must be a trained, experienced service 

technician.

4. After installation is complete, check out product 

operation as provided in these instructions.

5. Follow local codes for installation and application.

IMPORTANT

All wiring must agree with applicable codes, 

ordinances and regulations.

CAUTION

Electrical Shock or Equipment Damage Hazard.

Can shock individuals or short equipment 

circuitry.

Disconnect all power supplies before installation.

Location

The C7772 Wallplate Temperature Sensor should be located 

where it can sample an average air temperature. Avoid 

locations where air stratification can cause sensing errors. 

The sensor mounts directly on a 2 in. x 4 in. conduit box with 

the screws provided.

4-1/2

(114)

3-5/16

(84)

2-3/4 (70)

5/16 (8)

M16295A

Содержание C7772A

Страница 1: ... and other controllers that require a 10K ohm NTC Type III sensor The C7772 sensors provide a resistive output signal proportional to sensed room or space temperature The C7772 is well suited for low profile wall mounted applications where durability and tamper proof construction is desired such as schools prisons and institutions FEATURES Low profile when mounted on industry standard utility cond...

Страница 2: ...no appreciable drift thereafter No calibration of the device is possible Long term drift calibration maintenance through controller software is typically not necessary Humidity Ratings 5 to 95 rh non condensing Approvals National Electrical Code NEC Class II Fig 1 C7772 Dimensions in in mm INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to follow them could da...

Страница 3: ...sized from 16 to 20 AWG depending on the application The maximum length of wire from a device to the wallplate sensor is 300 ft 91m NOTE Erratic temperature readings from a sensor can be caused by the wiring practices described below These must be avoided to assure proper operation 1 Do not route temperature sensor wiring with building power wiring next to control contactors near light dimming cir...

Страница 4: ...ons are made Use an accurate thermometer of 1 F 0 5 C to measure the temperature at the sensor location To verify sensor accuracy use an ohmmeter to measure the resistance across the sensor wires and use Table 2 to check the accuracy of the specific model Table 2 Typical Resistance of Sensor Models Typical Resistance in ohms C7772A C7772F C7772G At 41 F 5 C 54 200 25 392 23 467 At 50 F 10 C 41 758...