background image

69-1085

7

CT2700 AN ELECTRONIC ROUND

 

 PROGRAMMABLE THERMOSTAT

c.

After the
thermostat
reverts back to
displaying room
temperature
(approximately five seconds), simultaneously
press

and

keys and hold for three

seconds. Release the keys after the display
changes.

d.

Press

within

five seconds.
The display
changes to
show current
cycle rate
setting.

2.

Cycles Per Hour

a.

Use

or

to select 1, 3, 6, or 9 cycles per

hour (cph). Refer to Table 3.

Table 3. Heating Cycle Rates

b.

Press

to

display the
current 

°

F or

°

C setting.

3.

Fahrenheit - Celsius Temperature

a.

Use

or

to choose between 

°

C and 

°

F.

b.

Press

to

display the
current 12- or
24-hour clock
setting.

4.

Clock Format

a.

Use

or

to choose either

 

a 12- or 24-

hour clock format.

Press

once to exit the

Installer Setup. Upon exiting,
the temperature setting will
be at 52

°

F (11

°

C). Pressing

six times returns the

thermostat to the normal
operational mode. End appears in the display.

5. Slide system switch to desired position.

TEMPORARY

AM

System

Program Setting (cph)

Gas or oil forced air

6

Electric furnace

9

Hotwater baseboard, High
efficiency (90+) gas furnace

3

Steam, radiant floor heat,
gravity

1

Symptom

Possible Cause

Corrective Action

Heating/cooling
equipment will not
operate

No AC power to
thermostat.

Check power to heating/cooling equipment:  

On/Off switch

Fuse or circuit breaker

Loose 24V connection: At thermostat; at furnace/air
conditioner

Incorrect wiring: check appropriate wiring diagram.

Thermostat inoperative.

See checkout section.

System switch on
thermostat in wrong
position.

Reset System switch.

Thermostat minimum-off
times operating for
cooling.

Wait five minutes or follow steps in Checkout section.

Incorrect wiring.

Check wiring.

Heating/cooling
equipment inoperative.

Consult equipment manufacturer instructions.

Partial display

Inoperative  thermostat.

Replace  thermostat.

Still in installer setup
mode.

See Installer Setup section for exit instructions.

No display

No power to thermostat.

Check power to thermostat.

Thermostat mounted
incorrectly on wallplate.

See installation instructions for correct mounting.

Temperature display
is incorrect

Thermostat is configured
for °F or °C.

Reconfigure the display. See Installer Setup section for
instructions to change the display.

Cannot change
temperature setting  

The upper or lower
temperature limits were
reached.

Check the temperature setpoints; temperature setting
range is 40°F (4°C) to 99°F (37°C).

TROUBLESHOOT YOUR THERMOSTAT

Содержание An Electronic Round CT2700

Страница 1: ...ructions in this manual Direct any questions concerning the application of this thermostat to Honeywell Customer Assistance at 1 800 468 1502 Monday Friday 7 00 a m 5 30 p m Central time RECYCLING THERMOSTAT If this thermostat is replacing a control that contains mercury in a sealed tube do not place your old control in the trash Contact your local waste management authority for instructions regar...

Страница 2: ...t need labeling Wrap wires around a pencil to keep them from falling back into the wall as shown in Fig 2 WIRES THROUGH WALL OPENING M5136 Fig 2 Wrapping wires around pencil Replacing Clock With C or C1 Clock Terminals If you are replacing a Honeywell Chronotherm Thermo stat you may find one or two wires that go to the C or C1 clock terminals on the Chronotherm Thermostat wiring wallplate Do not a...

Страница 3: ...s plaster or wood drill 7 32 inch holes Gently tap provided anchors into the drilled holes until flush with the wall Reposition the decorator cover plate and wallplate pulling wires through the wiring opening Loosely insert the mounting screws into the holes Level for appearance only the thermostat functions properly even when not level Tighten the mounting screws 4 WIRE WALLPLATE TERMINALS The CT...

Страница 4: ...s See Fig 8 Tighten the terminals M12537 FOR WRAPAROUND STRIP 7 16 INCHES 11 mm FOR STRAIGHT INSERTION STRIP 5 16 INCHES 8 mm Fig 8 CT2700 methods for wiring connection Plug the hole in the wall with insulation to help prevent drafts from adversely affecting thermostat operation 5 ADJUST FAN OPERATION SWITCH The thermostat fan operation switch labeled fuel switch in Fig 9 is set at the factory in ...

Страница 5: ...the cooling temperature settings NOTE To exit the sequence at any time press until End is displayed 1 Set Current Time a Press b Press or to set current time If you wish to change the preprogrammed time tempera ture settings follow steps 2 through 6 If not press the key until End is displayed or the thermostat will automatically return to normal operational mode within five minutes 2 Set WAKE Time...

Страница 6: ... to raise the temperature setting above the room temperature The cooling equipment should shut down Fan Slide the System switch to OFF and the Fan switch to ON The fan should run continuously CUSTOMIZE YOUR THERMOSTAT The following instructions provide the information neces sary to change the heating cycle rate to match your heating equipment choose Fahrenheit F or Celsius C and 12 or 24 hour cloc...

Страница 7: ...eat gravity 1 Symptom Possible Cause Corrective Action Heating cooling equipment will not operate No AC power to thermostat Check power to heating cooling equipment On Off switch Fuse or circuit breaker Loose 24V connection At thermostat at furnace air conditioner Incorrect wiring check appropriate wiring diagram Thermostat inoperative See checkout section System switch on thermostat in wrong posi...

Страница 8: ...mer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above Honeywell shall not be liable for any loss or damage of any kind including any incidental or consequential damages resulting directly or indirectly from any breach of any warranty expressed or implied or any other failure of this product Some states do not allow the exclusion or limitation o...

Отзывы: