Honeywell Ademco VISTA-15PCN Скачать руководство пользователя страница 1

 



K5305-1QGV3  2/11  Rev. A

2 Corporate Center Drive, Suite 100

P.O. Box 9040, Melville, NY 11747

Copyright © 2009 Honeywell International Inc.

www.honeywell.com/security







 

(A copy of the Installation and Setup Guide is available upon request)

FOR DOCUMENTATION AND ONLINE SUPPORT: http://www.security.honeywell.com/hsc/resources/MyWebTech    (see instructions K5305-1V9 or higher) 

These instructions apply to the following Honeywell security systems: 

ADEMCO VISTA-20P, VISTA-20PSIA, VISTA-20PCN, VISTA-15P, VISTA-15PSIA, VISTA-15PCN  
Features and procedures apply to all, except where differences are noted.

 

VISTA-20PSIA and VISTA-15PSIA are certified SIA-compliant controls that meet SIA specifications for 
False Alarm Reduction.

 

 

 

Connect Devices, Zones, Sounder, and Phone Line. 

Refer to the Wiring Diagram on the reverse side for connection information. NOTE: 

This system uses a range of reserved addresses for each type of device. 

 

1.  Connect keypads and other addressable devices to the ECP terminals 4-7. 

 

Refer to the wiring chart below for wire sizes and maximum wire run lengths. 

Wire Chart For Devices Drawing Aux Power From The Control (12V+ & 12V–) 

Wire 

TOTAL CURRENT OF ALL DEVICES CONNECTED TO A SINGLE WIRE RUN 

Size

 

50 mA or less

 

100 mA  

300 mA 

500 mA 

600 mA

 

#22  900ft (274m) 

450ft (137m) 

150ft (46m) 

90ft (27m) 

75ft (23m) 

#20  1400ft (427m) 

700ft (213m) 

240ft (73m) 

140ft (43m) 

120ft (37m) 

#18  1500ft (457m) 

1100ft (335m) 

350ft (107m) 

220ft (67m) 

170ft (52m) 

#16  1500ft (457m) 

1500ft (457m) 

550ft (168m) 

350ft (107m) 

270ft (82m) 

The length of all wire runs for both partitions combined must not exceed 1500 feet (457m) when unshielded quad 
conductor cable is used (750 feet if shielded cable is used).  

 

 

Standard Keypads

 (6150 / 6160 series) 

 

  Keypad addresses range from address 16-23. Set each keypad’s address accordingly. 

 

 

NOTE:

 Address 16 is reserved for the first keypad and is always enabled in the control. 

 

  Use data fields 

190-

196 to enable keypads and set their sounding options. 

 

 

Expander Modules

 (4219, 4229) 

 

  Connect desired field wiring to the module’s zone terminals. 

 

  Expander module addresses range from 07-11. Set each module’s DIP address accordingly. 

 

  Use 

56 Menu mode to program zone characteristics. 

 

 

Touchscreen Keypads

 (6270 / 6271 series, 8132 series; V20P = up to 4; V15P = up to 2) 

 

  Use of touchscreen keypads is independent from and in addition to the eight (8) standard keypads. 

 

  Set each touchscreen’s address accordingly (1, 2, 5, 6; see table on back) and enable in field 

189.  

 

  Make sure the auxiliary current drain is within the control’s limitation. Otherwise 

use an external 

power supply

 to power the touchscreen keypads. 

 

 

RF Receiver

 (5881, 5883, RF Keypad) 

 

  5881L / 5882L = up to 8 RF zones; 5881M / 5882M / 6150RF = up to 16 RF zones 

 

  5881H / 5882H / 5883 / 6160RF = up to system maximum RF zones 

 

  Set the receiver’s address to 00 using the module’s DIP switches. 

 

  If using wireless keypads, set field 

24 RF House ID Code appropriately. 

 

If receiver is mounted remotely, note the following: 

 

  Do not locate the receiver or transmitters on or near metal objects. This will decrease range and/or 

block transmissions. 

 

  Do not locate the RF receiver in an area of high RF interference (indicated by frequent or 

prolonged lighting of the receiver’s LED; random flicker is OK). 

 

  Do not locate RF receiver closer than 10 feet from any keypads. 

 

 

Relay Modules

 (4204)    

 

  Connect desired field wiring to the module’s relay contact terminals. 

 

  Relay module addresses range from address 12-15.Set each module’s DIP address accordingly. 

 

  Use 

79 / 

80 Menu modes to map each device address and define output functions. 

 

 

Communication Device

 (7847i, 7845GSM, 7845i-GSM, GSMV) 

 

  Set the communication device to address 03. 

 

  Use 

29 Menu mode to enable and program the device. 

 

 

AVS System 

 

  If used, follow the installation instructions provided with the module. 

 

  Connect the AVS module to the control’s ECP terminals and connect all other ECP devices to the 

AVS module’s ECP terminals. 

 

  Set the AVS address using its DIP switches: V15P = 08; V20P = 11 

 

  Use the desired AVS Quick Program Command to set pre-defined options: 

 

 

installer code + [#] + 0 + 3: enable AVS operation 

 

 

installer code + [#] + 0 + 4: enable AVS and enable panel sounds on AVST speaker 

 

  Use field 

55 Dynamic Signaling Priority to select the desired reporting paths. 

 

2.  Connect hardwire zones to the appropriate zone terminals 8-20. 

 

3.  On-Board Trigger Connections 

 

  Connect field wiring to the appropriate trigger pin using the SA4120XM-1 cable (if using 1361X10 

transformer) or the 4-wire cable (N4632-4, not supplied). 

 

  Trigger outputs are normally high, and go low upon programmed condition (can be set inverted).  

 

  Use 

79/

80 Menu modes to program the trigger outputs. 

 

  Output 17 (pin 1) = supports up to 100mA max; Output 18 (pin 5) = supports up to 20mA max 

 

4.  Install Wireless Zone Transmitters. 

 

  Use 

56 Menu mode to program wireless zones and enroll the transmitters. 

 

  Use the Go/No Go Test mode to verify adequate signal strength from each transmitter location:  

Enter Installer code + [#] + 4, then fault each transmitter and listen for 3 beeps at the keypad and 
the zone display. Exit mode: user code + 1 (OFF). 

 

5.  Connect the external sounder to terminals 3 and 4. 

 

  If supervised output desired, see Sounder Supervision wiring diagram on reverse side, and set field 

91 Option Selection for Bell Supervision. 

 

6.  Connect the phone line using terminals 21-24.  

 

  Use an RJ31X jack as shown in the diagram on reverse side. 

 

Mount the Control.

 

 
 

1.  Remove the cabinet door. Remove the cabinet 

knockouts needed for wiring entry. 

2.  Mount the control cabinet to a sturdy wall in a 

clean, dry area, which is not readily accessible to 
the general public, using fasteners or anchors (not 
supplied) with the four cabinet mounting holes. 

3.  When installation and wiring is completed, install 

the cabinet door and secure by using 2 screws 
(supplied) through the door's edge. 

 

OPTIONAL KEY LOCK: If desired, a key lock can be 
installed (K4445, not supplied). See Installation 
Instructions for details.

 

 

cab_6a-V0

SECURE

WITH

SCREWS

(2)

 

 

Securing the Cabinet Door 

 

4.  Mount the PC Board. Refer to the diagram below. If mounting an RF Receiver inside the cabinet,

remove the receiver board from its case, then insert the top of the board into the slots at the top of the 
cabinet. Install the control board below the receiver board using the clips and screws provided. Insert 
grounding lugs into the left-hand terminals of the antenna blocks and secure them with the screws 
provided. Insert the receiver's antennas into the blocks' right-hand terminals, and tighten the screws. 

 

+

+

CIRCUIT

BOARD

INSERT THE TOP OF THE

CIRCUIT BOARD INTO THE

SLOTS AT THE TOP OF THE

CABINET

DETAIL B

SIDE VIEW

OF MOUNTING CLIPS

DETAIL A

SIDE VIEW

OF BOARD   SUPPORTING

SLOTS

CIRCUIT

BOARD

cb_mount-001-V1

CABINET

CABINET

HANG TWO SHORT MOUNTING CLIPS

(PROVIDED) ON THE RAISED CABINET TABS.

SECURE THE BOARD TO THE

CABINET WITH THE ACCOMPANYING

SCREWS

 

Mounting the PC Board 

 

Connect the Transformer & Battery. 

 

1321 Transformer 

(1321CN in Canada)

 

  Do not plug the transformer into the AC outlet until all wiring connections to the control are complete. As 

a safety precaution, always power down the control when making such connections. 

 

1361X10 Transformer  

(required if using Powerline Carrier devices) 
1.  Splice one end of a 3-conductor cable to the wire ends of the SA4120XM-1 cable. 
2.  Connect the SA4120XM-1 cable plug to the 8-pin connector on the control.

3.  Connect the other end of the 3-conductor cable to the 1361X10 Transformer. 

 

Canadian Installations: 

For Powerline Carrier Devices, use the PSC04 X-10 Interface and trigger pins.

 

 

Battery Connections 

  After all connections to the control are completed and 

after AC power has been applied

, connect the 

red and black flying leads on the control board to the battery.  

 

IMPORTANT:

 This control will not power-up on battery alone (AC power must be applied). However, 

once the system is powered up, it will operate on battery if AC is lost. 

 

UL

For UL installations and Residential fire installations, refer to the chart below for the correct battery 

size required to meet the mandatory standby time. 

 

CALIFORNIA STATE FIRE MARSHALL (CSFM) AND UL RESIDENTIAL FIRE  
24-HOUR BATTERY BACKUP REQUIREMENTS 

The California State Fire Marshal and UL have regulations which require that all residential fire alarm 
control panels must be provided with a backup battery which has sufficient capacity to operate the panel 
and its attached peripheral devices for 24 hours in the intended standby condition, followed by at least 4 
minutes in the intended fire alarm signaling condition. This control panel can meet these requirements 
without using a supplementary power supply, provided that the panel’s auxiliary power and bell output 
currents are limited as listed below. 

 

OUTPUT LIMITATIONS AND REQUIRED BATTERIES

 

OUTPUT CURRENT LIMITS 

BATTERY INFORMATION 

Current Total 

 

600mA 
maximum total of 
auxiliary power 
plus bell output 
currents 

Max. Aux.Current 
45mA 
160mA 
200mA 
425mA 
500mA 

Battery Capacity (Amp/Hrs) 
4AH 
7AH 
8AH 
14AH 
17.2AH 

Recommended Battery (Yuasa No.) 
NP4-12 (or ADEMCO 467) 
NP7-12 
NP4-12 (two) ‡ 
NP7-12 (two) ‡ 
NPG18-12 

 

NOTE:

   Use two batteries, connected in parallel. Obtain an Ademco Battery Harness Kit SA5140-1. (Both batteries will 

fit inside the cabinet.)

 

Program the Control. 

Refer to the Programming Guide to program the control. 

(The control can also be programmed via the Compass Downloader.) 
1.  Enter Programming Mode: installer code + 8-0-0. 
2.  Change the default Installer Code using field 

20. 

3.  Enter the appropriate central station phone numbers and account numbers. 
4.  Program the system data field options as desired. 
4.  Use the various menu modes to program zones, relay outputs, descriptors, etc. 
5.  If AVS system is installed, use the appropriate AVS Quick Program Command. 
6.  Program Schedules (if used): Master code + [#] + 64 
7.  Enable RF button keyfobs (if used) and assign to user numbers accordingly. 
8.  Show the Master user how to change the default Master code: 

master code + [8] + 0-2 + new code + new code again 

 

Test the System. 

Sniffer Mode Test:

 To verify that all transmitters have been properly programmed, disarm all partitions. 

1.  From a keypad in partition 1, enter Installer code + [#] + 3. All programmed transmitters are displayed. 
2.  Fault all transmitters in turn. The display clears each transmitter as a signal is received. 
3.  Exit Sniffer mode: Installer code + 1 (OFF). Mode does not automatically expire; you must exit manually. 

 

System Test 

1.   Disarm the system and close all protected windows, doors, etc.  
2.  Enter the Installer code + [5] (TEST), then press 0 = walk. 

(Option 1 = Dial checks phone line integrity.)

 

3.  Listen. The external sounder should sound for about 1 second then turn off.  
4.  Fault all zones in turn and listen for three beeps from the keypad. ID of each faulted point should 

appear on the keypad display. The display clears when the zone is restored. 

5.  Test all smoke and CO detectors following the manufacturer's instructions and check the display. 
6.  When all zones have been checked and are intact (closed), there should be no zone identification 

numbers displayed on the keypad. 

7.  Exit test mode: security code + [1] (OFF). 

Major Features and Capacities 

 

Feature 

VISTA-20P 

VISTA-15P 

Partitions 

2 plus common area 

not partitioned  

Zones 

48 plus 16 keyfob zones for 
total of 64 zones: 

 8 hardwired zones (1-8)  

 Up to 40 additional wired 

zones (9-48) using up to 5 
4219/4229 modules 

 Up to 40 wireless zones 

(5800 series; zones 9-48) 

 4 configurable zone types 

32 zones plus 8 keyfob zones 
for total of 40 zones: 

 6 hardwired zones (1-6) 

 Up to 16 additional wired 

zones (9-24) using up to 2 
4219/4229 modules 

 Up to 26 wireless zones 

(5800 series; zones 9-34) 

 2 configurable zone types 

Security Codes 

48 

32 

Schedules 

32 

Keypad macros 

Event Logging 

100 

50 

Paging 

Keypads 

Touch Screen Devices 

4219, 4229 

4204 

Output Relays / X-10 devices 

16 

On-Board Triggers 

Output Functions 

48 

24 

 

WARRANTY INFORMATION 

For the latest warranty information, please go to: 

www.honeywell.com/security/hsc/resources/wa 

 