55
Summary of Audio Notification
SOUND CAUSE
DISPLAY
Loud, Interrupted*
Keypad & External
Fire Alarm
FIRE is displayed; descriptor of zone in
alarm is displayed.
Loud, Continuous*
Keypad & External
Burglary/Audible Emergency
Alarm
ALARM is displayed; descriptor of zone in
alarm is also displayed.
One Short Beep
(not repeated)
Keypad only
a. System disarm
b. System arming attempt
with an open zone.
c. Bypass verify
a. DISARMED/READY TO ARM is
displayed.
b. The number and descriptor of the open
protection zone are displayed.
c. Numbers and descriptors of the
bypassed protection zones are displayed
(One beep is heard for each zone
displayed). Subsequently, the following is
displayed: DISARMED BYPASS Ready to
Arm
One Short Beep
(once every 15
sec.) Keypad only
System is in test mode
Opened Zone identifications will appear.
One Beep
(every 60 sec.)
Keypad only
Low battery at a transmitter
LO BAT displayed with description of
transmitter.
Two Short Beeps
Keypad only
Arm Away or Maximum
ARMED AWAY or ARMED MAXIMUM is
displayed. Red ARMED indicator is lit.
Three Short Beeps
Keypad only
a. Arm Stay or Instant
b. Zone opened while system
is in Chime Mode.
c. Entry warning**
a. ARMED STAY ZONE BYPASSED or
ARMED INSTANT ZONE BYPASSED is
displayed. Red ARMED indicator is lit.
b. CHIME displayed, descriptor of open
protection zone will be displayed if the [
✱
]
key is pressed.
c. DISARM SYSTEM OR ALARM WILL
OCCUR is displayed.
Rapid Beeping
Keypad only
a. Trouble
b. AC power loss alert***
c. Memory of alarm
a. CHECK displayed. Descriptor of
troubled protection zone is displayed.
b. AC LOSS displayed (may alternate
with other displays that may be present).
c. FIRE or ALARM is displayed;
descriptor of zone in alarm is displayed.
Slow Beeping
Keypad only
a. Entry delay warning**
b. Exit delay warning (if
programmed)
a. DISARM SYSTEM OR ALARM WILL
OCCUR is displayed. Exceeding the delay
time without disarming causes alarm.
b. ARMED AWAY or ARMED MAXIMUM
is displayed along with You May Exit Now
* If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible
emergency is steady ring.
Содержание Ademco 8132
Страница 2: ......
Страница 6: ...Table of Contents Cont d 6 ...
Страница 14: ...System Overview cont d 14 ...
Страница 34: ...User Code Setup cont d 34 SCREEN ACTION ...
Страница 40: ...User Code Setup cont d 40 ...
Страница 52: ...Internet Features cont d 52 ...
Страница 68: ...Symphony Symphony i Setup cont d 68 ...
Страница 72: ...Maintaining Your System cont d 72 ...
Страница 74: ...Glossary Cont d 74 ...
Страница 79: ...79 ...