VIEWING THE KEYPAD ADDRESS 

During normal operation, press and hold down the [1] and [3] keys at the same time for about 3 seconds. The current 
keypad address is displayed. No key entry is allowed. Press any key to exit or wait 10 seconds to exit viewing mode. 
 

ENROLLING PROX TAGS 

Each Prox Tag is enrolled as a “User” in the alarm 
system. When enrolling the Tags, the last four digits of 
the Tag’s serial number is used as the User Code. Refer 
to the control’s User Guide for instructions on 
programming user codes. When programming is 
complete, test the system to ensure that each Prox Tag 
arms and disarms the system as specified. 

 

 

Swiping a Prox Tag when the system is in 
programming mode may cause programming fields to 
receive invalid entries. 

 

 

KEYPAD OPERATION 

For detailed system operating instructions, refer to the User Guide for the control panel used with this keypad. 

 

Prox Tag Operation 

Prox tags are used to alternately arm and disarm the system. 
Presenting a prox tag is functionally equivalent to entering a 
4-digit security code. 
To arm or disarm the system, present the prox tag at the location 
of the Proximity Label (bulls eye) on the front of the keypad. The 
system beeps to confirm that it is has been armed or disarmed. 

Arming

 (if system is disarmed): System arms in the AWAY mode. 

Disarming

 (if system is armed): System disarms and, if an alarm 

occurred, alarm sounding is 
silenced.

 

1

OFF

4

MAX

7

INSTANT

READY

2

AWAY

5

TEST

8

CODE

0

3

STAY

6

BYPASS

#

ARMED

READY

9

CHIME

A

B

C

D

SPEAKER

LCD

DISPLAY

PRESENT

PROX

TAG

HERE

LEDS

6160PX-001-V0

FUNCTION KEYS

 

Programmable Function Keys 

The keypad features function keys that may be 
programmed for panic alarms or other special functions 
such as macros. See the control's instructions for details. 

Function Keys 

Equivalent Key Pairs 

A

 

[1] and [

]

 

B

 

[

] and [#]

 

C

 

[3] and [#]

 

D

 

NONE 

 

 

 

  Function keys must be held down for at least 2 

seconds to activate the programmed function.  

  If functions other than panics are assigned to the 

programmable function keys, programmed panics 
must be initiated by pressing the programmed key 
pair. 

 

Function Key Labels 

A set of adhesive-backed labels with some typical function symbols (i.e., fire, police, personal emergency, etc.) is 
provided. These labels can be placed on or next to the keys to identify each key's function for the end user (as 
determined by the control panel's capability and programming; see the control's instructions).

 

Keypad Displays and LEDs 

The Keypad provides a two-line alphanumeric 
display and custom zone descriptors. The table 
identifies the Keypad’s LEDs and associated 
functions. 

 

LED Function 

ARMED 

Lights red when the system is armed in any mode. 

READY 

Lights green when the system is "ready" to be armed. 

 

 

SPECIFICATIONS 

Physical: 

5-5/16"H x 7-3/8"W x 1-3/16"D

 

Displays: 

2 x 16 alpha-numeric supertwist LCD, backlit

 

Sounder: 

Speaker (fire alarm is loud, pulsing single tone; burglary alarm is loud, continuous, dual tone)

 

Voltage:

 12VDC 

(power-limited) 

Current: 

165mA (ARMED LED lit, LCD backlight and sounder on), reduces to 40mA when panel is operating in 
standby mode (backlight off)

 

NFPA-72

   Compliant

Содержание Ademco 6160PX

Страница 1: ... of the case back away Insert the screwdriver in the side of the Keypad between the front and back case and gently twist to release the side locking tab Repeat for the other side Refer to Figure 1 for location of the case back release snaps and locking tabs 2 Route wiring from the control panel through the opening in the case back 3 Mount the case back to a wall or electrical box 4 Wire directly f...

Страница 2: ...own power up and start address mode again Defaults Keypad address 31 Prox Reader address 23 Keypad Address Mode 1 Enter keypad address mode Power up the Keypad Immediately press and hold down the 1 and 3 keys at the same time for 3 seconds If unable to enter address mode power up and try again The current keypad address is displayed and the cursor will be under the tens digit If only the red and b...

Страница 3: ...DE 0 3 STAY 6BYPASS ARMED READY 9CHIME A B C D SPEAKER LCD DISPLAY PRESENT PROX TAG HERE LEDS 6160PX 001 V0 FUNCTION KEYS Programmable Function Keys The keypad features function keys that may be programmed for panic alarms or other special functions such as macros See the control s instructions for details Function Keys Equivalent Key Pairs A 1 and B and C 3 and D NONE Function keys must be held d...

Страница 4: ...terference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is ...

Отзывы: