VIEWING THE KEYPAD ADDRESS
During normal operation, press and hold down the [1] and [3] keys at the same time for about 3 seconds. The current
keypad address is displayed. No key entry is allowed. Press any key to exit or wait 10 seconds to exit viewing mode.
ENROLLING PROX TAGS
Each Prox Tag is enrolled as a “User” in the alarm
system. When enrolling the Tags, the last four digits of
the Tag’s serial number is used as the User Code. Refer
to the control’s User Guide for instructions on
programming user codes. When programming is
complete, test the system to ensure that each Prox Tag
arms and disarms the system as specified.
Swiping a Prox Tag when the system is in
programming mode may cause programming fields to
receive invalid entries.
KEYPAD OPERATION
For detailed system operating instructions, refer to the User Guide for the control panel used with this keypad.
Prox Tag Operation
Prox tags are used to alternately arm and disarm the system.
Presenting a prox tag is functionally equivalent to entering a
4-digit security code.
To arm or disarm the system, present the prox tag at the location
of the Proximity Label (bulls eye) on the front of the keypad. The
system beeps to confirm that it is has been armed or disarmed.
Arming
(if system is disarmed): System arms in the AWAY mode.
Disarming
(if system is armed): System disarms and, if an alarm
occurred, alarm sounding is
silenced.
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
#
ARMED
READY
9
CHIME
A
B
C
D
SPEAKER
LCD
DISPLAY
PRESENT
PROX
TAG
HERE
LEDS
6160PX-001-V0
FUNCTION KEYS
Programmable Function Keys
The keypad features function keys that may be
programmed for panic alarms or other special functions
such as macros. See the control's instructions for details.
Function Keys
Equivalent Key Pairs
A
[1] and [
∗
]
B
[
∗
] and [#]
C
[3] and [#]
D
NONE
•
Function keys must be held down for at least 2
seconds to activate the programmed function.
•
If functions other than panics are assigned to the
programmable function keys, programmed panics
must be initiated by pressing the programmed key
pair.
Function Key Labels
A set of adhesive-backed labels with some typical function symbols (i.e., fire, police, personal emergency, etc.) is
provided. These labels can be placed on or next to the keys to identify each key's function for the end user (as
determined by the control panel's capability and programming; see the control's instructions).
Keypad Displays and LEDs
The Keypad provides a two-line alphanumeric
display and custom zone descriptors. The table
identifies the Keypad’s LEDs and associated
functions.
LED Function
ARMED
Lights red when the system is armed in any mode.
READY
Lights green when the system is "ready" to be armed.
SPECIFICATIONS
Physical:
5-5/16"H x 7-3/8"W x 1-3/16"D
Displays:
2 x 16 alpha-numeric supertwist LCD, backlit
Sounder:
Speaker (fire alarm is loud, pulsing single tone; burglary alarm is loud, continuous, dual tone)
Voltage:
12VDC
(power-limited)
Current:
165mA (ARMED LED lit, LCD backlight and sounder on), reduces to 40mA when panel is operating in
standby mode (backlight off)
NFPA-72