7.   Test the tamper function and adjust the plunger (if 

necessary) before securing the keypad to its case back 
with the screw (refer to Figure 3).  

8.  Install the cover or the optional door substitute trim, if 

the cover will not be used. 

 

6165EX-004-V1

READY

TEST

BYPASS

MAXIMUM

CODE

CHIME

INST

ANT

READY

AWAY

STAY

OFF

ARMED

B

C

D

A

6

5

4

9

0

8

7

3

2

1

OR

 

Figure 3 – Securing the Case  

(shown with cover removed) 

PROGRAMMING THE KEYPAD 
Setting the Keypad Address 

The keypad can either be set for an address of 00-30, or to the 
non-addressable mode (31). The keypad's default address is 31. 

To change the keypad's address, perform the following steps: 
1.  Enter address mode:  
 

Power up the keypad.  Within 60 seconds of power-up, 
press and hold down the [1] and [3] keys at the same time 
for 3 seconds.  (If unable to enter address mode, power 
down and try again.) 

 

The current keypad address will be displayed, and the 
tens” digit will blink.  If 10 seconds have passed with no 
key entry, the keypad automatically exits address mode.  
You must power down, power up and start address mode 
again. 

NOTE

: The keypad will not enter address mode if the panel to which 

it is connected is in programming mode.   

2.  Set the current address to “00”:  
 

Press [0] to clear the current “tens” digit.  The "ones" digit 
will blink.  Press [0] to clear the current "ones" digit.  The 
"tens" digit will blink. 

3.  Enter the keypad's address:  
 

Enter the proper "tens" digit of the keypad's address.  The 
"ones" digit will blink.  Enter the proper “ones” digit of the 
keypad's address.  Note that address “31” sets the keypad 
to non-addressable mode. 

4.  Exit address mode: 

Press [

] to exit address mode and proceed to display 

mode. 

Setting the Display Mode 

The 6149EX/6165EX has three optional display modes. The 
default option “d1” will be displayed on the keypad. 
Option 1: 

The display is always active. 

Option 2:  

The display and LEDs are blanked until a key is 
pressed. The display will remain active for 45 
seconds after the last key has been pressed. 

Option 3: 

The display and LEDs are blanked 45 seconds 
after the panel is armed and remains blank until 
the panel is disarmed 

1. Select keypad option: 
 

Enter the option number.  

2.  Exit the display mode. 
 Press 

[

] to save the display settings and exit 

programming mode.  

VIEWING THE KEYPAD ADDRESS 

Press and hold down the [1] and [3] keys at the same time for 
about 3 seconds.  The current address is displayed.  No key 
entry is allowed.  Press any key to exit or wait 10 seconds to 
exit viewing mode. 

SPECIFICATIONS 

Physical: 

 

4-7/8"H x 2-7/8"W x 1-1/4"D 

Displays: 

6149EX: Fixed-Word 

LCD. 

6165EX: 

2 x 16 alpha-numeric supertwist LCD (backlit). 

Sounder: 

Piezo-electric (fire alarm is loud, pulsing single 
tone; (all Keypads) burglary alarm is loud, 
continuous, dual tone).

 

Voltage:

  

12VDC 

Current:

 

   

6149EX: 

  60mA (ARMED LED lit and sounder on), 

reduces to 40mA when panel is operating in 
standby mode. 

6165EX: 

70mA (ARMED LED lit, LCD backlight and 
sounder on), reduces to 40mA when panel is 
operating in standby mode (backlight off). 

 

 

 

REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION 

AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 

 

To obtain applicable EU compliance Declaration of Conformities for this product, please refer to our Website  

http://www.security.honeywell.com/hsce/international/index.html

 

 

Honeywell Security and Custom Electronics 

2 Corporate Center Drive 
Melville, New York 11747 

www.honeywell.com/security 

 

Honeywell Security and Custom Electronics 

Newhouse Industrial Estate, Motherwell 

Lanarkshire, ML1 5SB, Scotland, United Kingdom

 

e-mail: [email protected]  

Telephone: +44 (0)1698 738200

 

Copyright © 2007 Honeywell International Inc.

 

 

‡K6205EXV3uŠ 

K6205EXV3  5/07  Rev. B 

Отзывы: