background image

WIRING CONNECTIONS 

With the battery still 

not

 inserted, connect the shock processor 

loop (if used) to the unit's loop TB1 terminals (see Detail "B").  
The contact loops must use closed circuit devices.  TB2 can be 
used for normally closed contacts. 

Note: 

If the contact loops are not used, no connection is needed 
across their terminals. 

 

"ENROLLING" THE TRANSMITTER SERIAL NUMBER 

Each 5819 Shock Processor has its own unique serial number 
permanently assigned during manufacture.  Each input of the 
transmitter also has a distinct "loop" number that must be input to 
the control panel during installation.  Assign each to an individual 
zone and designate the Input Type as "RF" (Supervised RF). 

The serial number can be input by one of the following methods: 

  "Enrolled" by transmitting from the device during zone 

programming (pressing the tamper switch, shorting any loop, 
etc.). 

  Entered through the keypad at the "Input S/N" or "Transmit 

Now" prompt during manual zone programming. 

  Entered through COMPASS Downloading Software and 

downloaded to the control.   

When programming the 5819 transmitter's serial number at 
the control panel, do the following: 

1.  At the "Input Type" prompt, enter "3" for RF (Supervised RF). 

2.  When prompted for the loop number, enter the input loop you 

are using (see Diagram 2).  See the control panel's 
installation instructions for specific programming procedures.

 

BATTERY INSTALLATION/REPLACEMENT 

1.  Remove the transmitter's cover as described in Mounting, 

Step 1. 

2. 

Observe correct polarity and insert the battery provided into 
the battery holder (see Diagram 2).   

3. 

Replace the cover, engage the hooks along one edge, and 
snap shut. 

Do not bend the antenna. 

Note: 

Replace with 

3V, 1300mAH Lithium battery

 only: 

 

Panasonic CR123A, Duracell DL123, DL123A, or 
ADEMCO 466. 

 

BATTERY CAUTION: 

Risk of fire, explosion, and burns.  Do not 

recharge, disassemble, heat above 212°F (100°C), or incinerate.  
Dispose of used batteries promptly.  Keep away from children. 

 

UNIT DIMENSIONS 

4.8" H x 1.5" W x 1" D 

 

TO THE INSTALLER 

Regular maintenance and inspection (at least annually by the 
installer) and frequent testing by the user are vital to continuous 
satisfactory operation of any alarm system.  The installer should 
assume the responsibility of developing and offering a regular 
maintenance program to the user, as well as acquainting the user 
with the proper operation and limitations of the alarm system and 
its component parts.  Recommendations must be included for a 
specific program of frequent testing (at least weekly) to insure the 
system's operation at all times. 

 

 

 

For the latest warranty information, please go to: 

http://www.security.honeywell.com/hsc/resources/wa/index.html

 

 

 

FCC AND INDUSTRY CANADA STATEMENT 

The user shall not make any changes or modifications to the equipment unless authorized by the 
Installation and Setup Guide or User Guide. 

 

This device complies with Part 15 of the FCC Rules and RSS210 of the Industry Canada. Operation 
is subject to the following two conditions: (1) This device may not cause harmful interference (2) This 
device must accept any interference received, including interference that may cause undesired 
operation. 
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. 
Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer 
d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les 
interférences causant une réception indésirable.

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

ÊN7491V5xŠ 

N7491V5    3/09  Rev. B

 

2 Corporate Center Drive, Suite 100 

P.O. Box 9040, Melville, NY  11747 

Copyright

 2009 

Honeywell

 

International Inc. 

Отзывы: