ACUIX IP Rugged Housing and Dome Installation Guide
Document 800-02460 Rev A
13
08/08
Step 1: Connect the Field and Terminal Block Wiring
Note
Each housing has a MAC address label attached to it that can be used to
differentiate ACUIX IP domes that are connected on the same network. For
more details, refer to the
ACUIX IP High Speed Dome User Guide
.
About the Terminal Blocks (J1, J4 and J6) and Switch (SW1)
The field wiring is connected to the interface board (see
) located at the top of
the ACUIX rugged housing. There are three terminal blocks (J1, J4 and J6) and one
switch (SW4) that require setting or wiring connections.
Terminal Blocks J1, J4 and J6
•
J1: With power supply pins. See
•
J4: The RJ-45 Ethernet network connector is used to connect the ACUIX IP dome to
your network with a network (10Base-T, 100Base-TX) cable. See
.
•
J6: With alarm activation pins (see
).
Restore to Factory Defaults Switch SW1
You can restore the configurations, compression settings and password factory defaults
using switch (SW1) on the housing interface board. When this switch is held down for
three seconds and LED2 starts to blink (see
), the dome reboots and all the
defaults are restored.
The wiring installation must be performed by qualified technical personnel and
must be in accordance with all national and local mechanical and electrical
codes.
To prevent damage to the interface board, follow standard industry precautions
for electrostatic discharge sensitive devices.