 IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE 

USING THIS HUMIDIFIER

When using electrical appliances, basic precautions should always be followed to reduce the risk 

of fire, electric shock, and injury to persons, including the following:
1. 

The humidifier should ALWAYS be placed on 

a firm, flat, waterproof surface at least three 

feet (1.2m) away from bedside, 12 inches 

(30cm) from the wall. 

KEEP OUT OF REACH 

OF CHILDREN AND PETS.

2. 

Be sure the humidifier is in a stable position 

and the power cord is away from heated 

surfaces and out of the way to prevent the 

humidifier from being overturned. 

3.  DO NOT 

leave the humidifier unattended in 

a closed room. The air can become saturated 

and leave condensation on walls and 

furniture. If room becomes saturated, open 

the door and turn the humidifier off or down.

4. 

Before using the humidifier, extend the 

cord and inspect for any signs of damage. 

DO NOT

 use the unit if the cord has been 

damaged. 

DO NOT

 operate with power cord 

coiled or with twist tie in place.

5. 

The humidifier has a polarized plug (one 

blade is wider than the other) as a safety 

feature. This plug will fit into a polarized 

outlet only one way. If the plug does not fit 

fully into the outlet, reverse the plug. If it still 

does not fit, contact a qualified electrician. 

DO NOT

 attempt to defeat this safety 

feature.

6.  CAUTION

To avoid fire or electric shock 

hazard, plug the humidifier directly into a 

120V AC electrical outlet. To avoid risk of  

fire, electric shock, or personal injury, 

NEVER 

use an extension cord or power strip. 

7. 

The humidifier should 

ALWAYS

 be 

unplugged and emptied when not in 

operation or while being cleaned. Turn off 

and unplug humidifier before moving. 

DO 

NOT

 move or tilt humidifier while it is in 

operation. Plug and unplug unit with dry 

hands. 

NEVER

 pull by cord.

8.  DO NOT 

operate the humidifier without 

water. Turn off and unplug unit when tank is 

empty, and the reset light is on.

9. 

Humidifier requires regular cleaning. Refer to 

and follow cleaning instructions.

10. DO NOT 

operate outdoors; this humidifier is 

intended for indoor residential use only.

11. DO NOT

 place in direct sunlight, high 

temperature areas or near computers or 

sensitive electronic equipment.

12. DO NOT 

cover or insert objects into any 

openings on the unit.

 DO NOT 

block intake 

or output vents.

13. DO NOT

 touch the nebulizer while the unit is 

plugged in, as burns could result.

14. DO NOT

 attempt to repair or adjust any 

electrical or mechanical functions on this 

humidifier. Doing so will void your warranty.

15. DO NOT

 add any essential oils or 

medications (e.g. Vicks VapoSteam®) into the 

Base Water Reservoir or Water Tank. Doing 

so could damage the humidifier and void the 

warranty.

16. 

For Residential Use Only

SAVE THESE INSTRUCTIONS

Содержание A005457R0

Страница 1: ...FIER UltrasonicHumidifier Diffuser Owner s Manual If you have any questions about the operation of this product please contact us 1 800 477 0457 ConsumerRelations HelenofTroy com www HoneywellPluggedIn com Humidifiers HUL530 SERIES FPO ...

Страница 2: ...ct a qualified electrician DO NOT attempt to defeat this safety feature 6 CAUTION To avoid fire or electric shock hazard plug the humidifier directly into a 120V AC electrical outlet To avoid risk of fire electric shock or personal injury NEVER use an extension cord or power strip 7 The humidifier should ALWAYS be unplugged and emptied when not in operation or while being cleaned Turn off and unpl...

Страница 3: ...ertical Mist Chamber to the Mist Outlet where the cool visible mist enters the room This humidifier will shut off when the water level is low or when the Tank is removed from the Base Components 1 Tank Handle not shown 2 Mist Outlet different for HUL525 and 545 3 Water Tank 4 Base 5 Power Knob 6 Essential Oil Pad 7 Essential Oil Tray 8 Cleaning Brush 9 Demin Cartridge not included 10 Reservoir 11 ...

Страница 4: ...tec PDC51 Demineralization Cartridge available through Consumer Relations see back of this manual FILLING REFILLING NOTE Tank should be carried using two hands one hand on the Tank Handle and the other supporting the bottom of the Tank Kaz USA Inc will not accept responsibility for property damage caused by water spillage This Humidifier holds 1 2 gallon 1 9L of water tank and reservoir combined F...

Страница 5: ...ob to a lower setting A comfortable humidity level is between 40 60 Consider using a humidity monitor to display current room humidity and temperature CONDENSATION If you notice condensation on the walls windows or around the humidifier the humidity level is too high Open doors to the room or turn off humidifier until humidity level drops Mist Outlet This humidifier features a directional Mist Out...

Страница 6: ...s turns light feature off Press HOLD to adjust brightness of lights Light will fade from bright to dim to off while holding Essential Oil Use Enjoy your favorite essential oils in two different ways As a traditional diffuser by adding oil directly to the water in the Tank The Water Tank and Reservoir are made with special materials that will not be damaged by oils The oil will be diffused into the...

Страница 7: ...e dust To install place the Cartridge in the base of the humidifier and push it all the way to the bottom of the reservoir WARNING BEFORE TURNING ON PLACE A FULL TANK OF WATER ON THE BASE TO FILL THE RESERVOIR LET IT SOAK FOR 15 MINUTES TO ALLOW WATER TO FLOW THROUGH THE CARTRIDGE AND FILL THE RESERVOIR IF THE HUMIDIFIER IS TURNED ON BEFORE THE RESERVOIR HAS FILLED WITH WATER IT COULD DAMAGE THE H...

Страница 8: ... Water Tank 2 Replace Tank Cap and swish vinegar in Tank to coat the inside of the Water Tank 3 Place Tank on Base allowing vinegar to drain into the Water Reservoir The vinegar will loosen mineral buildup on the Nebulizer Plunger and Float and in the bottom of the Tank Soak for 20 minutes 4 Remove Water Tank and empty vinegar into sink 5 Use a soft cloth or the included Cleaning Brush to gently c...

Страница 9: ...nd empty solution into sink 5 Pour solution from the Base into the sink Be sure to pour out of the side of the Base to avoid leaking into the Control Panel 6 Rinse Tank and Reservoir area with clean water until the smell of bleach is gone CAUTION DO NOT SUBMERGE BASE IN WATER DOING SO WILL DAMAGE THE HUMIDIFIER AND VOID THE WARRANTY END OF SEASON CARE AND STORAGE Follow the cleaning instructions w...

Страница 10: ...k for cracks on tank and contact Consumer Relations to replace if necessary Tighten Tank Cap Check to see if Gasket is attached to inside of Cap contact Consumer Relations for replacement Be sure unit is level Condensation foms around humidifier or on windows Mist intensity is set too high for room size or current humidity level Decrease mist output to low setting or open door to the room White du...

Страница 11: ...found to comply within the limits for Consumer ISM equipment pursuant to Part 18 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference with radio communi...

Страница 12: ...F THIS WARRANTY Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you also may have other rights which vary from jurisdiction to jurisdiction This warranty applies only to the original pur...

Страница 13: ...ell is a trademark of Honeywell International Inc used under license by Helen of Troy Limited Honeywell International Inc makes no representation or warranties with respect to this product Made in China PN A005457R0 For Responsible recycling please visit www RecycleNation com Para reciclar responsablemente por favor visite ...

Страница 14: ... 5 Material Page count 14 Revision 1 Release Date Date 30OCT20 Scale 1 1 Rerelease Date Colors Special Instructions Dielines Do not print Cyan 100 Magenta 100 Yellow 100 Black 100 Kaz USA Inc a Helen of Troy Company Creative Services Marlborough MA 01752 USA 1 508 490 7000 Quality Requirement of Artwork and Quality Clarification Process of Artwork Printing Meet Eng QS 06 02 CREATIVE DEPARTMENT ART...

Отзывы: