ALL
EFFECTIVITY
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Page 3-1
22 Apr 2019
23-15-49
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
ASPIRE-400
SECTION 3 – SYSTEM PRE-CONFIGURATION
1.
Aircraft Information
A.
Flight Information
(1)
The SDU retrieves the following values from the CFDS when enabled in the ORT:
(a)
Flight Phase
(b)
Flight Number
(c)
Aircraft ID (tail number), and sets the values to not available when CFDS labels
are never received.
2.
Owner Requirements Table (ORT)
A.
Secure ORT
(1)
The Secure ORT data file contains settings required for correct operation of Safety
Services. This file requires aircraft certification. The Secure ORT may contain other
parameter types. Type (1) Secure ORT information is retained in the SCM with a local
image resident in the SDU in non-volatile memory.
B.
User ORT
(1)
Type (4) User ORT information is retained in the SCM with a local image resident in the
SDU in non-volatile memory.
(2)
Any user modifications to User ORT selections are to the SDU stored copy of User ORT
data only and not to the SCM USER ORT copy.
C.
License Keys
(1)
License keys are installed in the SCM and activate optional SDU features. License keys
can be viewed and updated via the appropriate Maintenance Access Levels.
(2)
The ACD stores licenses on the SCM.
(3)
Each licensed feature that has specific CAN-TSO functionality is associated with a
secure ORT item and has no expiry date.
D.
Licensing
(1)
License keys are installed on the SCM, so that if the SDU is swapped for repair it is not
necessary to install new licenses. Each license is uniquely keyed to the individual SCM.
(2)
Activating a license feature requires both a valid license to be installed, and the
appropriate ORT parameters for that feature to be set. Some features can only have
permanent licenses and others support either permanent or time restricted licensing.
(3)
The Aspire 400 SDU supports non-expiring licensing of the following ACD controlled
features:
(a)
Class 6 terminal operation.
(b)
Dual Safety SATCOM.
(4)
For each of the above, the license is permanent even if constructed with an expiry date.
(5)
The Aspire 400 SDU supports permanent and expiring licensing of the following ACD
controlled features:
DRAFT
3rd rvw Draft as of:
29 January, 2020
Содержание 90402651-000
Страница 118: ...D R A F T 3rd rvw Draft as of 29 January 2020 ...
Страница 120: ...D R A F T 3rd rvw Draft as of 29 January 2020 ...
Страница 122: ...D R A F T 3rd rvw Draft as of 29 January 2020 ...
Страница 124: ...D R A F T 3rd rvw Draft as of 29 January 2020 ...
Страница 126: ...D R A F T 3rd rvw Draft as of 29 January 2020 ...
Страница 128: ...D R A F T 3rd rvw Draft as of 29 January 2020 ...