5
Running Load*
Description
kW
Amps at
120V 1ø
Amps at
240V 1ø
Electric heat per 1000 ft
2
12
n/a
50
Heat pump elements per 1000 ft
2
7
n/a
29
Dryer
5.5
n/a
23
Hot tub
10
n/a
50
Range oven/Stove top per burner
8
n/a
30
Electric hot water
4.5
n/a
19
General lighting and receptacles
per 1000 ft
2
3
24.9
n/a
Blow dryer
1.25
10.4
n/a
Dishwasher
1.5
12.5
n/a
Microwave
1
8.3
n/a
Toasters
1
8.3
n/a
Home Entertainment Center
1
8.3
n/a
Computer
1
8.3
n/a
Kitchen
1.5
12.5
n/a
Laundry
1.5
12.5
n/a
Non-Motor load Reference
Commercial
Please refer to equipment data plate and/or billing history for commercial details.
*Always check data plate for actual running amps.
Residential
Table 2