5
RESET FILTER INDICATOR/TURN LIGHT OFF
To Reset Filter Indicator
• Once the filter has been checked and replaced as needed,
the Filter Indicator will need to be reset.
• With the unit powered on, press and hold the appropriate
Filter Indicator button down for approximately 10
seconds until the light turns off
(Fig. 2)
.
REMOVING/CHANGING THE FILTERS
CAUTION: DISCONNECT FROM POWER SUPPLY BEFORE SERVICING
DO NOT attempt to wash either the Odor Reducing Pre-Filter or the HEPA Filter. They are not washable
and washing will damage the filters.
WARNING: FILTERS MAY BE HARMFUL IF INGESTED. AVOID BREATHING DUST WHEN
CHANGING FILTERS.
The only two parts requiring any service from you are the Odor Reducing Pre-Filter and the HEPA Filter. No tools
are needed. To remove or change either filter, disassemble the unit as shown below:
BEFORE OPERATING THE AIR PURIFIER, MAKE SURE PRE-FILTER IS IN PLACE.
To order replacement pre-filter or filter, refer to the “Accessories and Replacement
Filters” section.
Step 1:
Turn the air purifier off and unplug from the wall outlet.
Step 2:
To open and gain access to the filter, gently place the air purifier on its
side and unscrew the locking mechanism located on the bottom of the
unit
(Fig. 3)
.
Step 3:
Remove the base assembly from the air purifier.
Step 4:
Remove the filter or filter assembly (consisting of the HEPA Filter and
pre-filter) from the internal chamber.
Step 5:
If pre-filter is being changed, locate the seam of the pre-filter and
carefully separate the fastener to remove the pre-filter from the HEPA
Filter
(Fig. 4)
.
Step 6:
Discard used pre-filter if necessary. Check the HEPA Filter to ensure
it is not too dirty or seems to be clogged. Replace the HEPA Filter if
necessary.
Step 7:
Carefully wrap the pre-filter around the HEPA Filter so that the ends
meet
(Fig. 5)
. Fasten the ends together with the fastener provided.
Step 8:
Place the whole filter assembly back into the internal chamber. Close the
product by replacing the base and tightening the locking mechanism
until snug.
DO NOT OVER-TIGHTEN
.
Step 9:
Turn the air purifier into an upright position, plug into a wall outlet and it
is then ready for operation.
DO NOT
forget to reset the Filter Indicator.
50255 Line Ar
t
HEPA
CHECK
FILTER
RESET
PRE-FIL
TER
2
3
4
5