MAINTENANCE
Replacement Steps - Water Filters
l
It is recommended that the #1 sediment filter
and #2 RO filter be replaced at least once per
season or as needed.
l
When installing new filters, install #2 RO filter
first, followed by the #1 sediment filter.
Flow Control
1
. Disconnect the red tube at the connector that is
in the drain line approx. 12” from RO assembly,
leaving the connector attached to the RO sys-
tem.
2
. Remove and replace the cylindrical plastic flow
control that is inserted in the end of the red
tube removed from the connector. If the plastic
flow control does not appear to be in the end of
the red tubing, it may have stayed in the con-
nector when the tube was removed. Remove
the old flow control from the connector before
installing the new one in the end of the tubing.
Replace
FIG. 8
Turn cartridges in the direction of
the arrow to remove. Turn them
in the opposite direction to install.
#3
Staging Tank
#2
RO Filter
#1
Sediment Filter
Replace
Remove,
empty and
reconnect
NOTE:
Refer to the steam humidifer’s manual for