background image

3 - 3

About the Arm Mount Sled

Arm Mount Features

The arm-mounted sled:

Mounts the terminal on the user’s left or right arm

Helps protect the terminal from impact

Allows for use of the terminal display

Includes an option to support voice applications via an audio cable and headset

Supports a tethered ring scanner.

Terminal Features Not Used

When the terminal is installed in the arm mounted sled, the following features are not available:

Internal scanner

Micro-USB port

Scan Button

End Cap

Ring Scanner 
I/O Connector

Administrator or

Developer Defined

Button

Lock

Search Button

Volume Up/Down Buttons

(on left side of sled)

Power Button

(on top of end cap)

Touch Panel

Display

Start Button

Back Button

Sled

(not used with ring scanner)

Front Microphone

Содержание 26079

Страница 1: ...Dolphin 75e Wearable Solution with Windows Embedded 8 1 Handheld User s Guide ...

Страница 2: ...ishing performance or use of this material HII disclaims all responsibility for the selection and use of software and or hardware to achieve intended results This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII Copyrigh...

Страница 3: ...t Mount Applications 2 5 Install the Terminal in the Belt Mount Sled 2 5 Attach the Sled to the Belt Clip 2 7 Attach the Headset Optional 2 7 Adjusting Headset Microphone and Securing Cable 2 8 Connect the Ring Scanner Optional 2 9 Attaching the Ring to your Finger 2 9 Trigger Rotation 2 9 Chapter 3 About the Hardware About the Terminal 3 1 Turn Power On 3 1 Turn Power Off 3 1 Sleep Mode Suspend M...

Страница 4: ...a Bar Code 4 2 Automatic Scanning 4 3 Continuous Scanning 4 3 Configuring the Scan Demo Application 4 4 Scan Settings 4 4 Symbology Settings 4 4 Profiles 4 5 Advanced Ring Scanner Configuration 4 5 Custom Profiles 4 5 Microsoft POS APIs 4 6 Upgrading Ring Scanner Firmware 4 6 Installing EZConfig Scanning from the Web 4 6 Appendix A Ring Scanner Specifications 8620 Ring Scanner Specifications A 1 S...

Страница 5: ...iii Connecting and Disconnecting External Scanners B 1 DeviceAdded B 1 DeviceRemoved B 2 DeviceUpdated B 2 DeviceEnumCompleted B 2 DetectorStopped B 2 ...

Страница 6: ...iv ...

Страница 7: ...eywellaidc com and select Support Contact your service center to obtain a Return Material Authorization number RMA before you return the product To obtain warranty or non warranty service return your product to Honeywell postage paid with a copy of the dated pur chase record Limited Warranty Limited Warranty For warranty information go to www honeywellaidc com and click Resources Warranty Send Fee...

Страница 8: ...vi ...

Страница 9: ...ount with Voice Dolphin 75e Belt mount sled Belt mount clip Headset adapter cable Headset Arm Mount with Tethered Ring Scanner Dolphin 75e Arm mount sled Armband Tethered Ring Scanner Arm Mount with Voice and Tethered Ring Scanner Dolphin 75e Arm mount sled Armband Audio end cap to replace standard end cap Headset adapter cable Headset Tethered Ring Scanner About this Guide This guide provides ass...

Страница 10: ...e see page 4 1 Battery The Dolphin 75e is designed for use with battery part numbers BAT STANDARD 02 Li ion 3 7 V 6 179 watt hour and BAT EXTENDED 02 Li ion 3 7 V 12 358 watt hour manufactured for Honeywell International Inc We recommend use of Honeywell Li ion battery packs Use of any non Honeywell battery may result in damage not covered by the warranty Install the Battery 1 Unlock and remove ba...

Страница 11: ...ry door to ensure the door is properly closed Engage the door lock Charge the Battery For best results use a freshly charged battery for each shift For information on charging the terminal and the charge bases that are available see the User s Guide for your terminal ...

Страница 12: ...1 4 ...

Страница 13: ...wn to release the end cap 2 Push up on the right side the side with the lock of end cap Do not attempt to remove the end cap without sliding the lock first 3 Pull the end cap off the sled 4 Make sure the USB door is closed Rotate the door on the right side of the Dolphin 75e to close 5 Press until the door is flush with the side of the terminal Note If the door is not flush it may be difficult to ...

Страница 14: ...ull the rubber door out and rotate the door 180º as shown to prevent damage 8 If using the audio end cap make sure the audio cable is not installed in the end cap 9 Slide the end cap straight onto the sled until it clicks in place 10 Slide the lock closed to secure the end cap Standard End Cap Audio End Cap ...

Страница 15: ...rm band on 1 If the arm band straps are not fed through the buckles feed them through to form a loop before placing the arm band on the arm For ease of installation the straps should be kept looped through the buckles 2 Place and balance the arm band assembly on the top of the desired arm with the buckles toward the outside of the arm 3 Using the other hand pull each strap end straight away from t...

Страница 16: ...ck of sled with the notches on the arm band The end of the sled with the ring scanner connector must face toward the hand 3 If using the ring scanner see Connect the Ring Scanner Optional on page 2 9 slide the ring scanner over the index finger and adjust the strap if applicable for a comfortable fit 4 To remove the sled assembly unbuckle and loosen the straps It is not necessary to remove the str...

Страница 17: ...e the end cap 2 Push up on the right side the side with the lock of end cap Do not attempt to remove the end cap without sliding the lock first 3 Pull the end cap off the sled 4 Make sure the USB door is closed Rotate the door on the right side of the Dolphin 75e to close 5 Press until the door is flush with the side of the terminal Note If the door is not flush it may be difficult to remove the t...

Страница 18: ... door is open Pull the rubber door out and rotate the door 180º as shown to prevent damage 8 Make sure the audio cable is not installed in the end cap 9 Slide the end cap straight onto the sled until it clicks in place 10 Slide the lock closed to secure the end cap ...

Страница 19: ...to the belt clip Be sure to align tabs on the back of sled with the notches on the belt clip 2 Slide the clip over a belt to wear the assembly 1 Make sure the audio jack door is open as shown in the previous section 2 Slide the 3 5mm audio connector into the end cap 3 Attach the quick disconnect end of the headset adapter cable to the headset s cable ...

Страница 20: ... the small Talk label near the mouthpiece Make sure the Talk label is in front of your mouth The microphone cable can be routed over or under clothing Under Clothing Leave the cable exposed only at the top of the collar Be sure to leave a small loop of cable to allow movement of your head Over Clothing Use clothing clips to hold the cable close to your body Tuck the cable under the belt but leave ...

Страница 21: ...against or brace your finger on the scan aperture at any time Trigger Rotation The scanner head can be rotated 180 to be work on the right or left hand 1 Slide the ring scanner cable connector into the bottom of the sled until the connector ring clicks shut It is not necessary to remove the ring scanner from the sled before remov ing the Dolphin 75e from the sled 2 When connected to the Dolphin 75...

Страница 22: ...2 10 ...

Страница 23: ...up from the bottom of the screen to unlock the terminal To manually place the terminal in Sleep Mode press and release the Power button To adjust the time out limits 1 Touch Settings on the Apps list screen 2 Select lock screen to adjust the display time out limit or select sensor settings features to adjust the sleep time out limit Restart the Terminal You may need to restart the terminal to corr...

Страница 24: ...Yes again to confirm restoring the factory settings 4 Once the terminal resets the set up Welcome screen appears To perform a Factory Reset if your touchscreen is unresponsive and all other recovery methods have failed 1 Press and hold the Volume Down and Power buttons simultaneously until a large exclamation mark appears on the screen 2 Press the following buttons in this order Volume Up Volume D...

Страница 25: ...headset Supports a tethered ring scanner Terminal Features Not Used When the terminal is installed in the arm mounted sled the following features are not available Internal scanner Micro USB port Scan Button End Cap Ring Scanner I O Connector Administrator or Developer Defined Button Lock Search Button Volume Up Down Buttons on left side of sled Power Button on top of end cap Touch Panel Display S...

Страница 26: ...nplug the audio cable if used before removing the end cap 2 Slide the lock down to release the end cap 3 Push up on the right side of the end cap Do not attempt to remove the end cap without opening the lock first 4 Pull the end cap off of the sled 5 Slide the terminal out of the sled Use the notch in the bottom of the sled to push the terminal ...

Страница 27: ...et The sled encases the terminal including the touch panel and helps protect the terminal from impacts Terminal Features Not Used When the terminal is installed in the belt mounted sled the following features are not available Touch screen display Micro USB port Internal scanner Front Microphone Scan Button not used Sled Audio Cable Lock Start Button Administrator or Developer Defined Button End C...

Страница 28: ...ys unplug the audio cable before removing the end cap 2 Slide the lock down to release the end cap 3 Push up on the right side of the end cap Do not attempt to remove the end cap without opening the lock first 4 Pull the end cap off of the sled 5 Slide the terminal out of the sled Use the notch in the bottom of the sled to push the terminal ...

Страница 29: ...ing strap which is adjustable to your finger size Gray C ring for small to medium sized fingers self adjustable Black C ring for medium to large sized finger self adjustable The trigger and ring strap C ring are user replaceable as described in this section C Ring Scan Window Ring Strap Trigger Connector connect to sled ...

Страница 30: ...ng scanner open the connector ring with one hand pulling toward the outside of the sled 2 Push the ring scanner connector out of the sled Remove the Ring Strap C Ring 1 Turn the scanner 90 2 Press latch down 3 Remove the ring strap or c ring 1 2 ...

Страница 31: ...1 Connect ring latch with trigger catch 2 Press together until a click occurs 3 Turn 90 4 Ready to scan 1 Remove ring strap or c ring 2 Unscrew the 4 screws 3 Remove trigger Note When removing the trigger be careful that the metal spring is not dislodged ...

Страница 32: ...3 10 Replace the Trigger 1 Place trigger on the scanner 2 Screw in the 4 screws to secure the trigger 3 Snap on ring strap or c ring ...

Страница 33: ...ire explosion leakage or other hazard Replace the battery only with another battery that has been qualified with the system per this standard IEEE Std 1725 Use of an unqualified battery may present a risk of fire explosion leakage or other hazard Replace defective batteries immediately using a defective battery could damage the Dolphin terminal Never throw a used battery in the trash Promptly disp...

Страница 34: ...off the terminal see page 3 11 3 Unlock and remove the battery door 4 Pull the battery latch back and remove the battery 5 Insert the new battery and install the battery door Note For information on charging the terminal and the charge bases that are available see the User s Guide for your terminal ...

Страница 35: ...l flash feature to recognize the image 2 Install the SD card in the terminal 3 Plug the terminal in an external power source The terminal must have power for the entire flash process of it could become unstable 4 In the Apps list touch Settings manual flash 5 If a valid Windows Embedded 8 Handheld Flash ffu image is found on the SD card a Configuration received message appears under the SD Card he...

Страница 36: ...decode bar codes with the ring scanner When you start the Scan Demo app it automatically detects and connects to the ring scanner Note Scan Demo demonstrates the functionality of the ring scanner and is not intended as a functional business solution 1 On the All Apps list select Scan Demo 2 Scan Demo notifies the user that multiple scanners have been detected and tells you which scanner is the cur...

Страница 37: ...r Automatic Interval to set the number of seconds 0 to 30 between scan attempts 6 Press the Back button to return to the Scan screen 7 Press the trigger on the ring scanner to activate the scanner Once activated the ring scanner automatically scans and decodes bar codes presented in the field of view based on the Automatic Interval set To disable the feature set the Scan mode back to Normal Contin...

Страница 38: ...eet your application needs and then press the Back button to return to the Scan Demo screen Scan Settings Symbology Settings The Symbology Settings defines the bar code symbology types the ring scanner will decode when using the Scan Demo app Touch the toggle box next to a symbology to enable or disable the symbology for scanning Swipe up or down to scroll through the list of available symbologies...

Страница 39: ... used for the terminal s internal scanner and the ring scanner called USB scanner in the file Follow the instructions examples in the file for the USB scanner to apply settings to the ring scanner Profile Description HON Reset Resets all symbology settings to disabled HON GoodReadBeep Enable Enables the scanner driver issued good read beep When using Scan Demo you will hear 2 good read beeps One f...

Страница 40: ...ofiles gets the list of profiles supported Claimed BarcodeScanner SetActiveProfileAsync sets or reset any setting in the specified profile in the ring scanner BarcodeScanner IsProfileSupported determines whether the profile is supported Refer to the Microsoft API documentation for more information at https msdn microsoft com en us library windows apps windows devices pointofservice aspx Upgrading ...

Страница 41: ...to the c windows temp file 8 Double click on the Setup exe file Follow the screen prompts to install the EZConfig Scanning program 9 If you ve selected the defaults during installation you can click on Start Menu All Programs Honeywell EZConfig Scanning and select EZConfig for your browser ...

Страница 42: ...4 8 ...

Страница 43: ... Angle 45 typical 200 lux EAN UPC Motion Tolerance 580cm 228 in per second typical on 13 mil UPC EAN at optimal focus Minimum X dimension 1D codes 5 mil PDF417 6 7 mil 2D codes 10 mil Symbol Contrast 100 UPC 20 contrast Temperature Ranges Operating 4 F to 122 F 20 C to 50 C Storage 13 F to 158 F 25 C to 70 C Humidity 5 to 95 non condensing 50 C Tumble Exceeds 1000 0 5 m tumbles per IEC 60068 2 32 ...

Страница 44: ...h Extended Coupon Code EAN 8 EAN 13 GS1 128 GS1 Databar Interleaved 2 or 5 ISBN ISBN with Add On ISBT 128 Matrix 2 of 5 MSI Straight 2 of 5 IATA Straight 2 of 5 Industrial Telepen TLC 39 Trioptic Code UPC with Add On UPC A UPC E 2D Symbologies Aztec Codablock A Codablock F DataMatrix HanXin MaxiCode Micro PDF PDF417 QR Code TLC39 Postal Codes Australian Post British Post Canadian Post China Post I...

Страница 45: ...y result in haz ardous radiation exposure Laser Aperture Location Symbology Distance 5 mil C39 81 132 mm 3 2 5 2 in 10 mil C39 38 295 mm 1 5 11 6 in 100 13 mil UPC 43 371 mm 1 7 14 6 in 6 7 mil PDF417 54 158 mm 2 1 6 2 in 10 mil DataMatrix 64 175 mm 2 5 6 9 in Left Side of Scanner Laser Safety Label Compliance Label Right Side of Scanner Product Label Laser Aperture ...

Страница 46: ...A 4 ...

Страница 47: ...he App object also provides the callbacks supporting application lifecycle transitions Suspending and Resuming the Application On creation of a Windows Phone project the application template you choose will generate an App object that already has an OnSuspending callback method You will probably need to generate your own OnResuming callback method by chaining to the application s Resume event whic...

Страница 48: ...erAsync cbcs EnableScanner cbcs SetActiveSymbologiesAsync List uint symsToEnable cbcs SetActiveProfileAsync List string profilesToEnable DeviceEnumCompleted Optional to track but callback must be provided DetectorStopped Optional to track but callback must be provided To register these callbacks chain your support code to the events in the DeviceWatcher object To restore scanning when resuming cal...

Страница 49: ......

Страница 50: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 75EWS W8 ENUS UG Rev B 03 16 ...

Отзывы: