Honeywell 17000S Скачать руководство пользователя страница 4

The Honeywell 17000 series air cleaners are 3
speed air cleaners operated by turning the unit
on high for a few seconds, and then leaving it on
high for faster, more powerful air circulation, or
moving it to a lower setting as desired.

The 17000 series air cleaner is equipped with electronic controls and Intelli-Check

Filter Monitors to serve as a convenient reminder when to replace the pre-filter and
HEPA filter. The filter monitors will begin counting the hours of use once the unit is
powered on.

The Intelli-Check

Filter Monitors will count the hours of filter

use based on the unit’s operating speed, and will indicate
when the filter’s expected life has been reached. This is
beneficial because the expected life of a filter depends on the
amount of air and contaminants drawn through it. Once each
filter has reached its expected life, its light will remain on until
it is RESET. You may unplug the air cleaner without
interrupting the hours counted.

CHECK Expected Filter Life Usage.
To check the amount of expected filter life used, quickly press the filter monitor button
when the unit is turned on. It will flash up to 3 or 4 times, depending upon how much
expected filter life has been used. The filter monitors are intended as guidelines only,
as individual use may vary.

Check Pre-filter life used by quickly pressing the pre-filter monitor button:

NEW

2/3 life 

1/3 life left

Replace 

remains

remains

900 Hours*

Check HEPA filter life used by quickly pressing the HEPA filter monitor button:

NEW

3/4 life 

1/2 life left

1/4 life left

Replace 

remains

remains

remains             6,000 Hours*

*If operated an average of 12 hours a day on medium speed, the filter monitor light
will indicate replacement in about 3 months for the pre-filter, and about 1 year and 9
months for the HEPA filter.

NOTE: If operated on a higher speed for a greater number of hours each day, the
filter light monitors will indicate replacement sooner than if operated on a lower
speed for fewer hours each day.

RESET Filter Monitor After Filter Replacement.
When the filter monitor light remains on, it is time to replace the filter. Once the filter
has been replaced, you must reset the filter monitor. With the unit powered on, press
the filter monitor button down for a 5 second delay. The light will turn off.

17000 Series ...

Filter Check/Reset Monitors

POWER

HIGH

MEDIUM

LOW

FILTER CHECK/RESET

PRE-FILTER

HEPA

1 Flash

2 Flashes

3 Flashes

1 Flash

2 Flashes

3 Flashes

4 Flashes

Содержание 17000S

Страница 1: ...Portable HEPA Air Cleaners READ AND SAVE THESE INSTRUCTIONS Owner s Guide For Model Series 17000 Air Cleaners The Science of Clean Air ...

Страница 2: ... damp location 10 To disconnect the air cleaner first turn the air cleaner OFF and remove plug from the outlet 11 The air cleaner must be used in its upright position 12 Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air cleaner Do not block air outlets or intakes 13 Locate air cleaner near power outlet and avoid using an exte...

Страница 3: ...ust caused by vibration of the CPZ filter during shipment Use care to avoid soiling clothing carpets and other furnishings with the particles or dust The Honeywell HEPA air cleaner can be placed on the floor in almost any location However for best performance the air outlet slot should not be blocked for at least 3 feet 1 meter in all directions Due to the large volume of air drawn towards the air...

Страница 4: ...lash up to 3 or 4 times depending upon how much expected filter life has been used The filter monitors are intended as guidelines only as individual use may vary Check Pre filter life used by quickly pressing the pre filter monitor button NEW 2 3 life 1 3 life left Replace remains remains 900 Hours Check HEPA filter life used by quickly pressing the HEPA filter monitor button NEW 3 4 life 1 2 life...

Страница 5: ...ted carbon pre filter one primary HEPA filter and a CPZ odor and gas adsorbing filter The activated carbon pre filter captures lint and other large particles and helps protect the HEPA filter It also helps reduce common household odors The pre filter should be replaced at least every 3 months You may need to replace the pre filter more often if the unit is used in a smoking environment or if unple...

Страница 6: ...r replacing the CPZ filter use the enclosed CPZ filter reminder label to indicate the next time the filter is to be replaced If you store your Honeywell HEPA air cleaner for more than 30 days we recommend Remove both the primary HEPA filter and the activated carbon pre filter from the unit Also remove CPZ filter in model 17250 and 17450 series Discard the pre filter Discard the CPZ filter in model...

Страница 7: ...this product if it is found to be defective in material or workmanship within the limited warranty period Defective product should be returned to the place of purchase in accordance with store policy or to Honeywell C This warranty does not cover damage resulting from unauthorized attempts to repair or from any use not in accordance with this manual D This warranty DOES NOT cover the pre filter HE...

Отзывы: