10 - 3
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands. First, the scanner must be put in Manual Trigger
Mode by scanning a Manual Trigger Mode bar code (
), or by sending a serial menu command for triggering (
Once the scanner is in serial trigger mode, the trigger is activated and deactivated by sending the following commands:
Activate:
SYN T CR
Deactivate:
SYN U CR
The scanner scans until a bar code has been read, until the deactivate command is sent, or until the serial time-out has been
reached (see "Read Time-Out" on page 4-7 for a description, and the serial command on
Resetting the Custom Defaults
If you want the custom default settings restored to your scanner, scan the
Activate Custom Defaults
bar code below. This
resets the scanner to the custom default settings. If there are no custom defaults, it will reset the scanner to the factory default
settings. Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings.
Note: If using a cordless system, scanning this bar code also causes both the scanner and the base or Access Point to perform
a reset and become unlinked. The scanner must be placed in its base to re-establish the link. If using an Access Point,
the linking bar code must be scanned. See
beginning on page 3-1 for additional information.
The charts on the following pages list the factory default settings for each of the commands (indicated by an asterisk (*) on the
programming pages).
Menu Commands
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric entry
Page
Product Default Settings
Setting Custom Defaults
Set Custom Defaults
MNUCDP
Save Custom Defaults
MNUCDS
Resetting the Custom Defaults
Activate Custom Defaults
DEFALT
Programming the Interface
Plug and Play Codes
Keyboard Wedge:
IBM PC AT and Compatibles with CR suffix
PAP_AT
Laptop Direct Connect with CR suffix
PAPLTD
RS232 Serial Port
PAP232
Plug and Play Codes:
RS485
IBM Port 5B Interface
PAPP5B
IBM Port 9B HHBCR-1 Interface
PAP9B1
IBM Port 17 Interface
PAPP17
Activate Custom Defaults
Содержание 145*g1D
Страница 1: ...Voyager 1450g 1452g Series Area Imaging Scanner User s Guide ...
Страница 18: ...1 8 ...
Страница 42: ...2 24 ...
Страница 70: ...3 28 ...
Страница 87: ...4 17 Upright Vertical Bottom to Top Upside Down Vertical Top to Bottom ...
Страница 88: ...4 18 ...
Страница 102: ...6 10 Data Format 3 ...
Страница 154: ...9 4 ...
Страница 183: ...11 7 CCB01 010BT Base Part Number Serial Number and Revision Information location Compliance Label locations ...
Страница 184: ...11 8 ...
Страница 200: ...A 10 ...
Страница 203: ...4 CB 4 State Customer Bar Code 01 234 567094 987654321 01234567891 ID tag UPU 4 State J18CUSA8E6N062315014880T ...
Страница 204: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Страница 206: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com VG1450 UG Rev A 12 14 ...