T8775A,C THE DIGITAL ROUND
™
3
69-1677EF—03
CUSTOMIZE THERMOSTAT
Setting Fuel Switch (T8775C only)
The fuel switch is preset at the factory in the F
position. See Fig. 7. This is the correct setting for
gas or oil systems. If the T8775C is being installed
on an electric heat system, or a heat pump, set the
switch to the E position. The E setting allows the
fan to turn on immediately with the heating
equipment in a system where the G terminal is
connected.
Fig. 7. Fuel switch.
DIP Switch
To adjust the heat cycle rate or the
Fahrenheit/Celsius indication, locate DIP switch 1,
2 and 3 on the back of the thermostat. See Fig. 8.
Fig. 8. DIP switch.
Set Heat Cycle Rate
Use DIP switches 1 and 2 to set the heat cycle rate.
See Table 1.
Table 1. Heat Cycle Rate.
Fahrenheit/Celsius Indication
Use DIP switch 3 to set the desired temperature
indication. See Table 2.
Table 2. Temperature Indication.
Mounting Thermostat to Wallplate
Fig. 9. Mounting thermostat to wallplate.
OPERATION
Setting SYSTEM and FAN
Switches (T8775C only)
System and fan settings are controlled manually
by using the switches located at the top of the
thermostat. See Fig. 10.
M19497
FUEL SWITCH
ON
1
2
3
M19567
BACK OF THERMOSTAT
DIP SWITCH
Heating System
Cycles
Per
Hour
DIP
Switch 1
DIP
Switch 2
Steam, Gravity
1
On
On
High Efficiency Warm Air
(90%+ efficiency), Hot
Water, Heat Pump
3
Off
On
Gas or Oil Warm Air (factory
setting)
6
Off
Off
Electric Warm Air
9
On
Off
In Floor Radiant Heat
Check with
manufacturer for
recommended cycle
rate.
Fahrenheit/Celsius
Display
DIP Switch 3
Fahrenheit (factory
setting)
Off
Celsius
On
M19498
ENGAGE TABS
AT BOTTOM OF
THERMOSTAT
AND WALL PLATE.
PRESS UPPER
EDGE OF CASE
TO LATCH
Содержание The Digital Round T8775A