T140 Digital Thermostat

Installation and User Guide

Installation

Must be installed by a competent person. To ensure 
your safety, make sure the mains power is switched OFF  
before accessing wiring.

1.1 

Guidelines

1

1.2-1.5m

Bk-electronic GmbH 
Hardhofweg 40 
74821 Mosbach 
Germany 

For assistance with this product please visit  

livewell.honeywellhome.com

1.2 

Thermostat Wiring

For a 2-wire connection: no polarity.

Direct wiring to the circulator

Connection to the thermostat terminals of a furnace

For a 3-wire connection: observe the polarity

Wiring to a power-operated mixing control valve

1

 

Loosen the captive screw holding the faceplate to the mounting plate.

2

 

Pull the lower part of the faceplate to remove it from the mounting plate.

3

 

Loosen the screw (captive) holding the wire cover and remove the wire cover.

4

 

Pull wires through the hole in the mounting plate and secure the mounting plate to the wall  

(or onto an electrical box for line voltage wiring) using the enclosed wall anchors and screws.

5

 

Wire the thermostat to the heating system and, if necessary, connect the remote input.

6

 

Once wiring is complete, re-install the wire cover.

7

 

Use the switches located at the back of the faceplate to configure your thermostat according to your application.

8

 

Install the batteries.

9

 

Mount the faceplate on the mounting plate and tighten the screw.

1.3 

Remote Input Wiring

The thermostat is equipped with a remote input 
which allows connection of a telephone controller or 
a home automation system. When a signal is received 
through this input, the thermostat will automatically 
switch from normal operating mode to Vacation 
mode. For details on operating the telephone 
controller, refer to the instruction manual.

1.4 

Configure the Thermostat

The switches are located on the back of the faceplate. Default settings are highlighted.

1. If you change from °C to °F (or vice versa), you will need to reprogram your Comfort, Economy and Vacation settings.
2. For hot water installations, it is recommended to enable this option to activate the pump for one minute every 
24 hours to prevent pump seizure.

1.4.1 

Proportional Adaptive Mode (switch #5)

This mode analyzes previous cycles to define the the next duty cycle. This control mode guarantees optimal 
temperature control based on the system’s capacity. To extend the life of the system, a minimum On/Off time  
of 10% of the cycle has been implemented.
Ideal for:
• Radiant or convection electrical heating system
• Circulator control in a hot water system
• Electrical hot-air furnace
• Conventional gas or fuel hot-air furnace

Heating Cycle Selection (switches #1 and #2)

Select the cycle using switches #1 and #2. Short cycles help eliminate temperature variations,  
thus increasing user comfort.

1

6

7

8

9

2

3

4

5

Furnace

Relay

240 V

240 V

Home automation system 

or telephone controller

T140

Switch

Description

UP

DOWN

1 & 2

Cycles (proportional)

15 min (see 1.4.1)

Span (conventional)

0.5°C (0.9°F) (see 1.4.2)

3

Clock display

12H

24H

4

Temperature display 

1

°F

°C

5

Temperature control mode

Proportional (see 1.4.1)

Conventional (see 1.4.2)

6

Pump protection 

2

Deactivate

Activate

Cycles

EUROPE

Position

5 minutes

Not recommended for furnaces

10 minutes

Gas or electric wall furnace

15 minutes

Fuel or gas floor furnace, forced air heating

20 minutes

Commercial unit

Technical Specifications

Power supply: 

2 AA or LR6 alkaline batteries 1.5 V

Max. resistive load: 

5 A @ 240 VAC / 5 A @ 30 VDC

Max. inductive load: 

2 A @ 240 VAC / 2 A @ 30 VDC (P.F. = 0.4)

Remote input: 

12 VDC, ± 10%, 2.5 mA

Certifications: 

CE, c UL us

Control device: 

Electronic

Automatic action: 

Type 1 B

Number of programs: 

4 programs / day, total of 28 programs

Storage temperature: 

-20°C to 50°C (-4°F to 122°F)

Operating temperature: 

0°C to 50°C (32°F to 122°F), 95% R.H.

Temperature setting range: 

5°C to 30°C (40°F to 85°F)

Temperature display resolution: 

0.1 degree

Temperature reading accuracy: 

± 0.5°C (± 0.9°F)

Software: 

Class A

Protection class: 

II

Protection degree: 

IP 40

The terminals are designed to handle a cross-section of wire measuring up to 2.5 mm2 (14 AWG).

Basic Configuration

2.1 

Set the Time and Day

1

 

Set the time, using the Hour and Minute buttons. 

2

 

Set the day, using the Day button.

2.2 

Configure the Setpoints

2.2.1 

Comfort and Economy

These setpoints are associated to the schedule’s programs and are pre-programmed as follows:
Comfort 

 

R

 

20°C (68°F)  

Programs 1 and 3

Economy

 

ƒ

 

18°C (64°F)  

Programs 2 and 4

2.2.2 

Vacation

This pre-programmed setpoint is used when the Vacation mode is activated.
Vacation 

  

10°C (50°F)

Select the Operating Mode

3.1 

Automatic 

This mode executes the schedule. To activate:
•  Press Manual/Auto until   is displayed. The program setpoint icon is displayed.

3.1.1 

Temporary Bypass

When in Automatic mode, you can temporarily bypass the current program setpoint until  
the beginning of the next program. To bypass:
•  Set the desired temperature 

pq

 OR quickly press

 

R

 

or

 

ƒ

 

to use a pre-defined setpoint.

3.2 

Manual

 

J

This mode allows you to maintain a constant temperature.
•  Press Manual/Auto until is displayed.
•  Set temperature 

pq

 OR quickly press

 

R

 

or

 

ƒ

 

to use a pre-defined setpoint.

3.3 

Vacation

Maintains a specific temperature when away for a prolonged absence (e.g. vacation).
•  From the thermostat, quickly press to activate.

Program Your Schedule

The thermostat allows four setting changes for each day of the week. There are no pre-set programs. Your 
heating system switches betwwen the Comfort setpoint and the Economy setpoint according to the times you 
would have set.

1.4.2 

Conventional mode with anticipation (switch #5)

This mode is compatible with all heating systems.

Programmable Span Selection (switches #1 and #2)

Select the span using switches #1 and #2. The default temperature span is 0.5°C. For example, if the 
temperature setpoint is 20°C, the heating system will turn on at 19.5°C and turn off at 20.5°C.

Span

Hot Water Heating

Forced Air Heating

Position

0,3°C

Not recommended  

for furnaces

Not recommended for 

central units

0,4°C

Gas or electric wall furnace

Radiant or convection 

electric heating

0,5°C

Fuel or gas floor furnace, 

forced air heating

Central heating

0,6°C

Commercial unit

1.5 

Install the Batteries

When you first install the batteries, the unit runs a sequence of tests and a complete reset to zero.  
The screen should display 0:00 MO

J

 

and the ambient temperature. The current setpoint is 20°C.

1.5.1 Replacing the batteries

The thermostat will display an icon indicating that the batteries must be replaced. This icon  
will be displayed for 60 days; after this delay, the thermostat will shut down the heating unit.  
The time and programming are saved for 15 seconds when replacing the batteries.

4.1 

Set or Modify the Programs

1

 

Press Program. The screen displays MO and PROG 1.

2

 

Press Day to select the day (hold for 3 seconds to select all days of the week).

3

 

Press Hour and Minute to set the start time. To clear an entry, press Clear, the time zone displays --:-- when 
the program is inactive.

4

 

Press Program to select the program number (2, 3 or 4).

5

 

Repeat steps 3 and 4 for remaining programs.

6

 

Press Manual/Auto to exit.

To erase program for desired day:

1

 

Press Program until desired program is selected.

2

 

Press Day to select desired day.

3

 

Press Clear to erase the time (--:--).

4

 

Press Manual/Auto to exit.

2

3

4

5

2.2.3 

To Modify a Setpoint

1

 

Set the temperature using 

pq

.

2

 

Press and hold one of the setpoint buttons (

R

 

or

 

ƒ

 

or 

 ) until the icon is displayed  

on the screen (approx. 3 seconds).

2.3 

View the Current Setpoint

To view the current setpoint, quickly press once one of the arrow buttons 

pq

The screen displays the setpoint; the arrow indicates a setpoint.

Programs

Associated Setpoint

Time

PROG 1

R

 

(Comfort) 

Wake-up

PROG 2

 

ƒ

 

(Economy)

Leave

PROG 3

R

 

(Comfort) 

Return

PROG 4

 

ƒ

 

(Economy)

Sleep

Connection to telephone controller  

or a home automation system

© 2019 Resideo Technologies, Inc.  
This product manufactured by Resideo and its affiliates.  
The Honeywell Home trademark is used under license 
from Honeywell International Inc. All rights reserved.

EN + DE

33-00057ED-02

Содержание Resideo T140

Страница 1: ...s A Protection class II Protection degree IP 40 The terminals are designed to handle a cross section of wire measuring up to 2 5 mm2 14 AWG Basic Configuration 2 1 Set the Time and Day 1 Set the time...

Страница 2: ...und Tag einstellen 1 Stellen Sie die Uhrzeit mit den Tasten Stunde und Minute ein 2 Stellen Sie den Tag mit der Taste Day Tag ein 2 2 Sollwerte konfigurieren 2 2 1 Komfort und Sparbetrieb Diese Sollwe...

Страница 3: ...2 R gler le jour l aide de la touche Day 2 2 R glage des consignes 2 2 1 Confort et conomie Ces consignes sont associ es aux r glages de l horaire et sont pr programm es comme suit Confort R 20 C 68 F...

Страница 4: ...van maximaal 2 5 mm2 14 AWG Basisconfiguratie 2 1 Tijd en datum instellen 1 Stel de tijd in met de knoppen voor de uren en de minuten 2 Stel de datum in met de knop voor de datum 2 2 Instelpunten conf...

Страница 5: ...do el bot n Day 2 2 Configuraci n de las temperaturas 2 2 1 Confort y Econom a Las consignas de temperatura est n asociadas a los programas horarios como se indica Confort R 20 C 68 F Programas 1 y 3...

Страница 6: ...di regolazione del giorno 2 2 Configurazione dei setpoint 2 2 1 Comfort e Risparmio Questi setpoint sono associati ai programmi e predefiniti come segue Comfort R 20 C 68 F Programmi 1 e 3 Risparmio...

Страница 7: ...nfigurace 2 1 Nastaven asu a dne 1 Nastavte as pomoc tla tek Hour a Minute 2 Nastavte den pomoc tla tka Day 2 2 Konfigurace teplot 2 2 1 Komfort a sporn Tyto teploty se vztahuj k program m rozvrhu a j...

Страница 8: ...te pomocou tla idiel Hour a Minute 2 De nastavte pomocou tla idla Day 2 2 Konfigurujte nastaven hodnoty 2 2 1 Re imy Komfort a spora energie Tieto nastaven hodnoty s visia s programami harmonogramu a...

Страница 9: ...a konfiguracja 2 1 Ustawianie Czasu i Dnia 1 Ustaw czas za pomoc przycisk w Godzina i Minuta 2 Ustaw dzie za pomoc przycisku Dzie 2 2 Konfiguracja zadanych warto ci 2 2 1 Komfort i Ekonomiczne Te zada...

Страница 10: ...yorsan nyomja meg a Rvagy a gombot az el re meghat rozott alap rt k haszn lat hoz 3 3 Szabads g Meghat rozott h m rs kletet tart fenn hosszabb t voll t eset n pl szabads g Az aktiv l shoz r viden nyom...

Отзывы: