Installation

Must be installed by a competent person. To ensure your safety, make sure 
the mains power is switched OFF before accessing wiring. The programmer 
must be installed on an electrical box.

1.1  Remove the faceplate

Loosen the locking screw (the screw is  
captive and cannot be completely removed).

2

  Pull and lift the bottom of the faceplate to  

remove it from its mounting plate.

1.2  Connect the programmer

Connect power to terminals L (line) and N (neutral).
Connect the pilot wire inputs of the thermostats to  
terminals FP1, FP2 and FP3.

FP134 Pilot-wire Programmer

Installation and User Guide (EN)

FP134 is an electronic six-order pilot-wire programmer that allows separate 
temperature control of three zones using four programs per day. The FP134 
programmer has three pilot-wire outputs can be connected to thermostats 
or controller that accept pilot-wire signals. 
The FP134 programmer has a remote input to which a telephone controller, 
a home automation system (HAS) or an energy manager can be connected. 
When a signal is received from any of these devices, FP134 forwards the 
order to the heating units.

Display

1

  Time

2

  Heating modes 

R

: Comfort mode 

ƒ

: Setback modes 

(icon is steady in 3,5k setback;  
flashes in 1k and 2k setbacks) 

T

: Frost protection 
: Off

3

  Operating modes 

- Manual mode 
- Auto mode

4

  Zone selected (the letter A appears  

when all 3 zones are selected)

5

  Current program (applicable to  

automatic mode only)

Connections

FP134 

buttons

Energy 

manager

Telephone 

controller/HAS

Pilot wire order

Signals

R

Maintain temperature  

at setpoint (Comfort)

No signal

ƒ

ü

ü

Maintain temperature  

at setpoint minus 3,5°C  

(3,5k setback)

T

ü

Maintain temperature  

at 7°C (frost protection)

ü

Turn heating Off (Off)

ü

Maintain temperature  

at setpoint minus 1°C  

(1k setback)

ü

Maintain temperature  

at setpoint minus 2°C  

(2k setback)

1

  Order buttons

Mode selection button

Zone selection button

4

  Time/day setting button

Program button

Return button

Selection button

Display

The following table shows the different means of initiating an order.

1

4

5

6

7

2

3

Telephone controller/Home 

automation system (optional)

OR

Energy 

Manager

(Optional)

(Optional)

1

2

3

4

5

1

1.3  Connect the remote input (optional)

Telephone controller or Home automation system

Connect to terminals L and TEL of the programmer respectively.

NOTE: For details on wiring and operating the telephone controller or home 
automation system, refer to the instruction manual of particular models.

Energy Manager

Connect the pilot wire output of the energy manager to the TEL input  
of the programmer.

1.4  Complete the installation

Fix the mounting plate to the wall.

Install the faceplate on the  
mounting plate and lock  
them together using  
the locking screw.

1.5  Apply power to the programmer

Time and day setting

1  Press  . The hours display flashes.
2  Set the hours using the 

pq

 buttons.

3  Press  . The minutes display flashes.
4  Set the minutes using the 

pq

 buttons.

5  Press  . The day display flashes.
6  Set the day using the 

pq

 buttons.

7  Press 

8

 

to exit the time and day settings

Power-up

During power-up, the 
FP134 perform a series  
of test for approximately  
5 seconds. Afterwards,  
the programmer displays 
the following:

Flashes to indicate 

that the time and day 

must be set.

The programmer is 

in manual mode.

All three zones 

are in comfort 

mode.

Zone 1 is selected.

2