Determining Best Location for Humidifier

CAUTION

Temperature and Static Pressure Hazard.
Can cause property or equipment damage.

Locate humidifier where ambient temperature is between 32°F (0°C) and 160°F (71°C). 
Do not install humidifier where freezing temperatures could occur. 
Be sure supply plenum static pressure is no greater than 0.4 in. wc and water pressure is no greater than 
124 psi.

• Select a location for the humidifier on the supply (warm air stream) plenum. See Fig. 1.
• Select a location that cannot damage the air conditioner A-coil during installation.
• Do not locate the humidifier on the furnace body.
• Allow adequate clearance in front of and above the humidifier so you can easily remove the cover to perform 

routine maintenance. 

Mount the humidifier at least 3 in. (78 mm) above the furnace body to allow adequate space for the sole-
noid valve and drain line.

Mount the humidifier in a conditioned space to prevent freezing.

Fig. 1. Typical humidifier installation locations.

Selecting Water Supply Location

• Use either hard or soft water in the humidifier and either hot or cold water. The water flow rate, with the 

humidifier running, is 3.5 gal/hr (13 liters/hr) to flush the pad and provide moisture for evaporation. 

• Make sure the length of the 1/4” of feed water tubing is adequate to connect the water supply shut-off valve 

with the humidifier solenoid valve.

Locating Closest Floor Drain 

• Select location with access to a floor drain to provide drainage for air conditioner condensation and 

humidifier drainage.

• If you do not have a drain available, we recommend that you install the Resideo Whole House Drum or Disk 

Humidifier. Make sure that the drain tubing is adequate to reach from the humidifier drain connection to the 
floor drain. 

Selecting Location for Humidistat

• Select a location for the humidistat on the return plenum or on the wall in the living space. 

Mounting on the return plenum is the easiest installation for the control wiring circuit.

For return duct mounting, the humidistat should be mounted upstream from the humidifier or bypass so that it 
is properly sensing the relative humidity of the living space. Locate the control at least 8 in. (203 mm) upstream 
from the humidifier in the return air duct. (See Fig 2.)

M12808C

HORIZONT

AL

DOWN

FL

O

LOWBO

Y

RETURN

RETURN

RETURN

HIGHBO

Y

RETURN

Содержание HE360

Страница 1: ...OWNER S MANUAL 69 2631ES 13 HE360 Humidifier HE360A1075 HE360D1075 Read before installing Input 120 Vac 60 Hz 0 7A...

Страница 2: ...comfort of your home INSTALLATION Preparing for the Installation Be sure to identify all the included accessories Table 1 and make sure the appropriate tools and accessories are available before begin...

Страница 3: ...ater in the humidifier and either hot or cold water The water flow rate with the humidifier running is 3 5 gal hr 13 liters hr to flush the pad and provide moisture for evaporation Make sure the lengt...

Страница 4: ...drill into any air conditioning or electrical accessory CAUTION Sharp Edges Installation Hazard Can cause personal injury Wear gloves and safety glasses 1 Turn off power to the air handing system at...

Страница 5: ...umidifier 7 Position the securing clips as shown in Fig 4 Fig 4 Position securing clips M12809A COVER ASSEMBLY HUMIDIFIER PAD ASSEMBLY FEED TUBE NOZZLE WATER DISTRIBUTION TRAY HUMIDIFIER HOUSING THUMB...

Страница 6: ...nstall the three sheet metal screws on the top of the humidifier housing Secure the hous ing with the three remaining screws Fig 5 Installing humidifier on duct 11 Reinstall the humidifier pad assembl...

Страница 7: ...ing over the tubing Discard copper compression ring provided with valve NOTE To prevent leaking use plastic Delrin sleeve rings with plastic tubing Use copper sleeve rings only with copper tubing NOTE...

Страница 8: ...rubber gaskets in each duct 6 Connect the other end of the tubing to the applicable pressure connection on the switch a Connect supply duct tubing to the connection b Connect return duct tubing to the...

Страница 9: ...ing installation 2 Mark the duct tube hole Hold the wallplate up to the desired location on the duct and make a mark inside the duct tube hole Fig 11 3 Drill the duct tube hole Find your mark and dril...

Страница 10: ...late Secure the wallplate to the duct with sheet metal screws provided Fig 14 6 Run wires through the back plate Run wires through the top or bottom channel on the back plate when ductmounted If insta...

Страница 11: ...bundle 2 to the upper U terminal 7 At the humidistat wire hut the white wire from bundle 2 to the white wire in bundle 3 going to the pres sure switch 8 At the humidistat wire the red wire from bundl...

Страница 12: ...is not used with H6062 as the outside temperature drops a lower humidity setting is recommended to accommodate dewpoint effects These settings should reduce the accumulation of moisture and ice on win...

Страница 13: ...d water a running tap to clean the hose 11 Reattach the drain hose to the drain fitting 12 Snap the water nozzle back on the tray 13 Be sure the marked end of the pad is facing up Place the tray on th...

Страница 14: ...ick Plumbing Verify plumbing connections Check for kinks Shut off valve Verify shut off valve is turned on If a saddle valve is used verify that needle pierces water line and then backs out needle to...

Страница 15: ...s caused by damage which occurred while the product was in the possession of a consumer Resideo s sole responsibility shall be to repair or replace the product within the terms stated above RESIDEO SH...

Страница 16: ...deo Technologies Inc and its affiliates Todos los derechos reservados La marca comercial Honeywell Home se utiliza bajo licencia de Honeywell International Inc Este producto es fabricado por Resideo T...

Страница 17: ...MANUAL DE INSTRUCCIONES 69 2631ES 13 Humidificador HE360 HE360A1075 HE360D1075 Leer antes de instalar Entrada 120 V CA 60 Hz 0 7A...

Страница 18: ...accesorios necesarios del Cuadro 1 y de la lista Herramientas y accesorios sugeridos antes de comenzar la instalaci n Herramientas y accesorios sugeridos Entre las herramientas y los accesorios necesa...

Страница 19: ...ciente espacio para la v lvula del solenoide y la tuber a de drenaje Monte el humidificador en un espacio acondicionado para evitar el congelamiento Fig 1 Ubicaciones de instalaci n t picas para el hu...

Страница 20: ...tato sea adecuado para llegar desde el solenoide del humidificador hasta el interruptor de presi n y el humidistato Instalaci n del humidificador ADVERTENCIA Voltaje peligroso Puede causar lesiones pe...

Страница 21: ...Use un alicate seg n sea necesario para aplanar los bordes cortados Consulte la Fig 5 9 Presione los sujetadores de fijaci n hasta que queden completamente asentados 10 Perfore agujeros e inserte los...

Страница 22: ...quipo de aire acondicionado No utilice tuber a de gas 2 Instale la v lvula de cierre de agua en la l nea de suministro de agua en la ubicaci n seleccionada seg n el c digo local 3 Utilice una tuber a...

Страница 23: ...e de piso consulte la Fig 7 a Coloque la abrazadera del drenaje sobre la tuber a b Empuje la tuber a sobre la boquilla de drenaje del humidificador c Apriete la abrazadera alrededor de la tuber a util...

Страница 24: ...ecte el otro extremo de la tuber a a la conexi n de presi n pertinente en el interruptor a Conecte la tuber a del conducto de suministro a la conexi n b Conecte la tuber a del conducto de retorno a la...

Страница 25: ...que el agujero del tubo del conducto Sostenga la placa de pared en la ubicaci n deseada del con ducto y haga una marca dentro del agujero del tubo del conducto Fig 11 3 Taladre el agujero del tubo del...

Страница 26: ...omo un termostato en una pared pase los cables a trav s de la parte posterior Fig 15 CABLEADO PRECAUCI N Voltaje peligroso Puede causar lesiones personales o da o al equipo Desconecte el suministro el...

Страница 27: ...La tuber a de alimentaci n no tiene torceduras La tuber a de drenaje desciende continuamente y termina en el drenaje de piso La manguera de agua dentro del humidificador est conectada a la bandeja de...

Страница 28: ...ara eliminar la humedad MANTENIMIENTO DE SU HUMIDIFICADOR Un programa regular de mantenimiento prolonga la vida til de su humidificador y hace que su casa sea m s confortable La frecuencia de limpieza...

Страница 29: ...ocar la cubierta del humidificador 16 Verifique el funcionamiento del humidificador siguiendo los pasos de la secci n Revisi n de su humidificador para lograr el funcionamiento adecuado REVISI N DE SU...

Страница 30: ...iones de plomer a Revise si hay torceduras V lvula de cierre Verifique que la v lvula de cierre est abierta Si se utiliza una v lvula de asiento verifique que la aguja perfore la l nea de agua y luego...

Страница 31: ...reemplazo de la pieza si el defecto ocurre por da o causado por el consumidor o desgaste normal La nica responsabilidad de Instromet ser reparar o reemplazar el producto dentro de los t rminos establ...

Страница 32: ...Resideo Technologies Inc and its affiliates Todos los derechos reservados La marca comercial Honeywell Home se utiliza bajo licencia de Honeywell International Inc Este producto es fabricado por Resi...

Отзывы: