ATTENTION: MERCURY RECYCLING NOTICE

This product does not contain mercury. 

However, this product may replace a product 

that contains mercury. Mercury and products 

containing mercury should not be discarded in 

household trash.
For more information on how and where to 

properly recycle a thermostat containing 

mercury in the United States, please refer to the 

Thermostat Recycling Corporation at  

www.thermostat-recycle.org.
For mercury thermostat recycling in Canada, 

please refer to Switch the Stat at  

www.switchthestat.ca

N O   M E R C U RY

Hg

Preparation for Installation

1.  Before proceeding, first turn off power to the healing system at the main 

fuse or circuit breaker panel. See warning note.

2.  When replacing your old thermostat, remove the two mounting screws of 

your old thermostat and pull out of the junction box.

3.  Label the wires in the junction box, so that they match the thermostat 

wires to which they are attached.

4.  Disconnect the old thermostat.

Wiring and Installation

1.  When installing your new thermostat, remove the prestripped insulation 

tips from your new thermostat´s leads.

2.  Re-connect wires in the junction box to matching leadwires on back of 

the thennostat. See wiring diagram below. NOTE: Do not connect power 

supply LI-L2 to L1-TI, to avoid thermostat burn - out.

CAUTION

Use certified soIderless wire connectors (not included) approved for 

No. 12 wires and tighten them firmly so they cannot be pulled off. 

Failure to tighten firmly may cause overheated connection.

3.  Remove thermostat cover.

4.  Mount the thermostat to the junction box using two capitive screws 

provided. Do not press the knob or bimetal sensing element during 

mounting.

5.  Replace the thermostat cover.

Содержание CT60A

Страница 1: ...s 4 wire thermostat Wire connectors are not supplied Use certified wire connectors approved for No 12 wires WARNING Electrical Shock Hazard This thermostat is a line voltage control 120 240 Volts Do n...

Страница 2: ...o mounting screws of your old thermostat and pull out of the junction box 3 Label the wires in the junction box so that they match the thermostat wires to which they are attached 4 Disconnect the old...

Страница 3: ...conductors Otherwise a fire hazard may result 3 L1 T1 closes on temperature fall M35685 L1 HOT L2 ELECTRIC HEATER SOLDERLESS CONNECTORS RED WIRE CT60B L1 L2 T1 T2 1 2 3 Fig 2 CT60B wiring diagram 1 Po...

Страница 4: ...s little or no attention Most problems can generally be traced to the following Symptom Checkout Action No heat Blown fuse or tripped circuit breaker Replace fuse or reset breaker Improper connections...

Страница 5: ...ge which occurred while the product was in the possession of a consumer Resideo s sole responsibility shall be to repair or replace the product within the terms stated above RESIDEO SHALL NOT BE LIABL...

Страница 6: ...Inc Golden Valley MN 1 800 468 1502 2019 Resideo Technologies Inc The Honeywell Home trademark is used under license from Honeywell International Inc All rights reserved Resideo Inc 1985 Douglas Drive...

Страница 7: ...ils Les connecteurs ne sont pas fournis Utiliser des con necteurs certifi s approuv s pour les fils n 12 AVERTISSEMENT Risque de chocs lectriques Ce thermostat est un appareil tension secteur 120 volt...

Страница 8: ...ies et approuves pour des fils n 12 Bien serrer les connecteurs pour qu ils ne puissent tre retires Si les connecteurs ne sont pas bien serres il peut y avoir un risque de surchauffe 3 En tenant ferme...

Страница 9: ...eut Y avoir un risque d incendie 3 L1 T1 ferme lors d une baisse de temp rature L1 L2 T1 T2 1 2 3 MF35685 L1 CHAUD L2 APPAREILDE CHAUFFAGE CONNECTEURS SANSSOUDURE FIL HOUGE CT60B Fig 2 CT60B sch ma de...

Страница 10: ...a temp rature voulue D pannage Le thermostat exige peu ou pas d attention La plupart des probl mes sont d crits au tableau qui suit Sympt mes V rifications Mesure prendre Pas de chaleur Le fusible a f...

Страница 11: ...mite r parer ou remplacer le produit conform ment aux modalit s susmentionn es RESIDEO N EST EN AUCUN CAS RESPONSABLE DES PERTES OU DOMMAGES Y COMPRIS LES DOMMAGES INDIRECTS OU ACCESSOIRES D COULANT D...

Страница 12: ...00145EF 03 M S Rev 06 19 Imprim aux tats Unis Ce produit est fabriqu par Resideo Technologies Inc Golden Valley MN 1 800 468 1502 2019 Resideo Technologies Inc La marque de commerce Honeywell Home est...

Отзывы: