Page 11
Revision 2.2 P/N: 201827
Honey Bee Manufacturing Ltd.
AirFLEX Header - Quick Start Guide
Massey Ferguson Combine Calibration/Settings
NOTE: In order for header height control to function on a
Massey Ferguson combine, a ball valve must be installed on
the accumulator and closed.
1. In the combine setup screen:
• Select the “Flex” header type
• Enter the width of your header under “Header Width”
• Set the “Cutoff Height” to 80%.
• Ensure the Reel PPR matches he value in the Automatix
system (accessible via the automatix system menu).
This value should automatically match when the
combine type is selected in the main Automatix menu.
2. In the Header Control Table settings tab:
• Set both Max UP PWM and Max DOWN PWM to 100.
• Set both Max RIGHT PWM and Max LEFT PWM to 80.
3. On the AHHC tab:
• Ensure Automatic Header Height Control is enabled
(check mark)
• Set the sensitivity to 50% as a starting point.
4. On the Tilt tab:
• Set the Autotilt sensitivity to 20%
• Set the Autolevel sensitivity to 20%
Note: The optimal lateral tilt sensitivity value is directly related
to the auto header height control sensitivity and can be found
using the following equation:
AHHC Sensitivity
2
- 10%
(
)
Lateral Tilt Sensitivity =