OWNER INFORMATION (CONT.)

IMPORTANT SAFETY INFORMATION

Review  the  owner's  manual  prior  to  using  the

water filtration system.

Install  the  system  for  its  intended  use  as  out-

lined in this manual.

Do NOT operate the system if the cord or plug is

damaged; if it is not working properly, or if it has

been damaged or dropped.

Only qualified personnel should service the sys-

tem.

Do NOT allow the cord or plug in water.

Do NOT allow the cord near heated surfaces.

Only use this system with cold water.

Carefully observe the following warnings and cau-

tions, which appear throughout this manual. 

Unplug the power cord before servicing this sys-

tem.

Follow all local electrical codes and any other

applicable codes with all electrical connections.

Install  a  ground  fault  circuit  interrupter  (GFCI)

on the circuit to this system.

Do  NOT  modify  the  power  cord.  If  necessary,

contact a qualified electrician.

Do NOT use an extension cord.

If the power cord is damaged, contact the man-

ufacturer, its service agent, or a similarly quali-

fied person.

Follow all local plumbing code and any other ap-

plicable code when installing the system.

If the system is installed on metallic plumbing,

an electrical bonding jumper must be installed

across the inlet and outlet pipes.

Water pressure must not exceed 100 psig (690

kPa). If necessary, install a water pressure regu-

lator.

If the inlet water pressure is less than 50 psig

(345 kPa), install a booster system.

Do  NOT  allow  the  trans  membrane  pressure

to exceed 45 psi (310 kPa). Trans membrane

pressure is the pressure differential (delta) from

the  influent  side  of  the  membrane  wall  to  the

effluent side on the membrane wall.

Protect  the  ultrafilter  from  becoming  dry  by

keeping it wet and sealed at all times.

Do NOT allow the ultrafilter to freeze during op-

eration or storage to avoid damage.

Do NOT allow long-term exposure to direct sun-

light or other UV sources.

Avoid  any  sudden  changes  in  operating  tem-

perature.  Make  any  changes  to  the  operating

temperature slowly.

Do NOT drop or bump the system to avoid dam-

age or breakage of the filter. Be sure to handle

carefully during transportation and installation.

Do  NOT  use  strong  solvents  containing  chlo-

rine,  or  concentrated  acids  on  the  ultrafilter

membrane.

Do  NOT  use  strong  solvents  or  concentrated

acids on the plastic parts of the system, which

includes  acetone,  methyl  acetate  (nail  polish

remover);  hexane  (spot  removers);  turpentine,

toluene (paint thinners); dry cleaning solutions,

insecticides.

Flush all pipes before installing the system. Any

abrasive materials can cause irreversible dam-

age to the membrane.

Do NOT use sharp objects, like knives, sandpa-

per, or other tools on the plastic parts of the sys-

tem. A cut or nick on a plastic part can weaken it

and cause a leak.

Do NOT use abrasive cleaners on plastic parts.

Protect the system from shock, pressure surg-

es, or pulsation that can occur in water pipes.

Use a water hammer arrestor to reduce pres-

sure shock on the inlet side of the the system if

necessary.

Содержание AUF-4210-0000X

Страница 1: ...ULTRAFILTRATION SYSTEMS UF 40 SERIES OWNER S MANUAL W A T E R F I L T R A T I O N S O L U T I O N S...

Страница 2: ...formation below and have it ready when calling for assistance The serial number can be found on the specification plate located on the sys tem Purchased From Date of Purchase Model No Serial No Mfg No...

Страница 3: ...0 psig 345 kPa install a booster system Do NOT allow the trans membrane pressure to exceed 45 psi 310 kPa Trans membrane pressure is the pressure differential delta from the influent side of the membr...

Страница 4: ...e Filtration Systems Water Treatment Systems excluding water filters and water treatment replacement cartridges are warranted to be free from manufacturers defects in materials and workmanship for a p...

Страница 5: ...LSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS...

Страница 6: ...HREE PLACE DECIM MATERIAL CLASS 180 UNLESS OTHERWISE DO NOT SCALE DR SEE NOTE FINISH 13 04 56 34 46 41 4X 1 00 7 47 NOTES UNLESS OTHERWISE SPECIFIED MATERIAL SEE COMPONENT DRAWING S 1 REVISIONS REV DE...

Страница 7: ...E PROPERTY OF TST WATER LLC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF TST WATER LLC IS PROHIBITED PROPRIETARY AND CONFIDENTIAL DIMENSIONS ARE IN INCHES TOLERANCES FRACTI...

Страница 8: ...5P 4 20 2 1 4925P 15 UF 4221 4933X 4 20 2 1 4933X 15 UF 4221 4933P 4 20 2 1 4933P 15 UF 4211 4925X 4 20 1 1 4925X 8 UF 4211 4925P 4 20 1 1 4925P 8 UF 4211 4933X 4 20 1 1 4933X 8 UF 4211 4933P 4 20 1 1...

Страница 9: ...33X 30 UF 4422 4933P 4 40 2 2 4933P 30 UF 4423 4925X 4 40 2 3 4925X 30 UF 4423 4925P 4 40 2 3 4925P 30 UF 4423 4933X 4 40 2 3 4933X 30 UF 4423 4933P 4 40 2 3 4933P 30 AUF 4210 0000X 4 20 1 0 N A 8 AUF...

Страница 10: ...e Capacity NSF Std 42 NSF Std 53 Scale Inhibitor Dia Ht HWF 4925XHC 105298 5 0 7 5 265 000 Chlorine No No 4 1 2 20 HWF 4925PHC 105299 5 0 7 5 265 000 Chlorine No Yes 4 1 2 20 HWF 4933X 105284 0 2 3 5...

Страница 11: ...t the system so it has access to a drain for flushing Be sure to mount the system prior to any filtra tion processes for consumable water ex water softener Optional bracket and hardware available for...

Страница 12: ...making the drain valve connection be sure to follow these guidelines The tubing must be able support the flow rate which depends on the inlet water pressure inlet pipe size and system The tubing shou...

Страница 13: ...as a 3 4 NPT female thread Be sure to NOT overtighten the fittings which could cause damage to the fittings When making connections to the system be sure to use plastic fittings and a pipe thread seal...

Страница 14: ...of the ultrafilter rinse valve STARTING THE CONTROLLER 1 Plug the power cord into the controller 2 Plug the other end of the power cord into the outlet 3 The system will automatically enter Flush Mod...

Страница 15: ...of the nearest faucet or tap 8 Once the smell of sanitizer is noticeable close the faucet or tap 9 Allow the system to stand without water flow for at least 15 minutes to sanitize the pipes RINSING TH...

Страница 16: ...will continue to be filtered but the system will NOT flush This could plug the ultrafilter prematurely and may reduce its lifespan The flush is automated to take place in one hour in tervals and last...

Страница 17: ...se 12 Reinstall ultrafilter sub assembly into manifold blocks already mounted Once connector tubes are seated reinstall rear manifold clips Then tighten endcap clamps both top and bottom 13 Rinse the...

Страница 18: ...duration setting and store it into memory To reset the UF controller to the factory default set tings press and hold the FL Up and Down arrow buttons together CHECK PERMEATE TANK PRE CHARGE The air c...

Страница 19: ...SINGLE UF 4211 4925P 4X20 W SINGLE 4925P POST FILTER 108011 X4 30 5 6 14 13 22 1 7 8 7 17 2 17 22 14 1 9 10 11 5 13 16 8 2 22 16 22 12 3 3 2 17 1 16 4 2 17 1 15 19 20 21 23 18 7 22 18 15 16 22 19 4 2...

Страница 20: ...E UF 4411 4925P 4X40 W SINGLE 4925P POST FILTER 108013 X4 12 6 5 11 22 1 7 12 1 9 10 8 14 17 6 11 22 17 13 22 13 7 8 22 2 4 3 2 3 4 19 17 22 2 13 2 13 7 1 16 19 21 20 23 22 1 17 17 EXTRS FITTINGS AS N...

Страница 21: ...6098 MANIFOLD HEAD CLIPS BGX A 1 16 105283 CARTRIDGE AQBE 4925X 5 0 MICRON BLOCK 1 17 306035 FITTING PLUG W O RINGS 4 18 306036 FITTING 3 4 INCH MNPT W O RINGS 1 19 502804 VALVE SOLENOID 24VAC 3 4 INC...

Страница 22: ...22 Rev 8 10 20 NOTES...

Страница 23: ...23 Rev 8 10 20 NOTES...

Страница 24: ......

Отзывы: