OPERATION
59
Voltage Selector Switch
Disconnect or turn OFF all appliances or tools connected to the generator before
changing the voltage selector switch position.
The generator may be damaged if the switch position is changed with loads
connected and operating.
The power available to each receptacle depends on the position of the voltage
selector switch.
120V ONLY POSITION
When the voltage selector switch is in the 120V ONLY position, you do not need
to spread the load over the receptacles. You must, however, make sure the load
on any receptacle does not exceed its available power shown in the table above
and the total load does not exceed the total current available.
Total Current Available:
37.5 A (EB5000X)
45.8 A (EB6500X)
Switch
Position
Receptacle
Available Power
EB5000X
EB6500X
120V ONLY
30A at 120V
30A at 120V
20A at 120V
20A at 120V
20A at 120V
20A at 120V
30A at 120V
30A at 120V
None
None
120V/240V
18.8A at 120V
22.9A at 120V
18.8A at 120V
20A at 120V
18.8A at 120V
20A at 120V
-
18.8A at 240V
22.9A at 240V
31Z238200.book 59 ページ 2020年2月20日 木曜日 午前10時57分