CONTROLS & FEATURES

Eco-Throttle Switch

Parallel Operation Outlets

ON:

OFF:

O

O

F

F

F

F

PARALLEL OPERATION OUTLETS

O

O

N

N

ECO-THROTTLE SWITCH

TM

TM

The Eco-Throttle system automatically reduces engine speed when

loads are turned off or disconnected. When appliances are turned on

or reconnected, the engine returns to the proper speed to power the

electrical load.

If high electrical loads are connected simultaneously, turn the

Eco-Throttle switch to the OFF position to reduce voltage changes.

Recommended to minimize fuel consumption and further

reduce noise levels when less than a full load is applied to the

generator.

These outlets are used for connecting the EU2000i Companion to

either an EU2000i or another EU2000i Companion generator for

parallel operation (see page

). A Honda approved parallel operation

cable kit (optional equipment) is required for parallel operation. This

kit can be purchased from an authorized Honda generator dealer.

The Eco-Throttle system does not operate.

30

10/03/11 17:00:32 31Z07700_016

4

Содержание EU 2000i

Страница 1: ...erator EU 2000i OPERATION INSTRUCTIONS DeeJay s Event Rentals LLC 704 Beacon Lake Drive Raleigh NC 27610 919 255 3335 www DeeJaysEvents com Controls Pages 1 6 Startup Instructions Pages 7 10 Shut Down...

Страница 2: ...UND TERMINAL FUEL TANK CAP VENT LEVER STARTER GRIP MAINTENANCE COVER 20A RECEPTACLE 30A twist lock receptacle TM Use the two illustrations on these pages to locate and identify the most frequently use...

Страница 3: ...fuel valve OFF Stops the engine and closes the fuel valve ON Running position opens the fuel valve and allows the engine to be started Pulling the starter grip operates the recoil starter to crank th...

Страница 4: ...vent lever must be in the ON position for the engine to run When the engine is not in use leave the vent lever in the OFF position to reduce the possibility of fuel leakage Allow the engine to cool we...

Страница 5: ...eously turn the Eco Throttle switch to the OFF position to reduce voltage changes Recommended to minimize fuel consumption and further reduce noise levels when less than a full load is applied to the...

Страница 6: ...matically switch OFF if there is a short circuit or a significant overload of the generator at the 20A receptacle If the circuit protector switches OFF automatically check that the appliance is workin...

Страница 7: ...the oil level in the crankcase can fall below a safe limit the Oil Alert indicator red comes on and the Oil Alert system automatically will stop the engine the engine switch will remain in the ON pos...

Страница 8: ...ools and appliances Before connecting an AC appliance or power cord to the generator Inspect cords and plugs and replace if damaged Make sure that the appliance is in good working order Faulty applian...

Страница 9: ...to AC Operation see page for connecting loads to the generator Refer to SAFE OPERATING PRECAUTIONS on page and perform the IS YOUR GENERATOR READY TO GO checks see page Operating this generator less...

Страница 10: ...the Eco Throttle switch is in the OFF position or more time will be required for warm up Turn the engine switch to the ON position To start a cold engine move the choke lever to the CLOSED position To...

Страница 11: ...hown If the choke lever was moved to the CLOSED position to start the engine gradually move it to the OPEN position as the engine warms up If you wish to use the Eco Throttle system turn the Eco Throt...

Страница 12: ...op the engine in an emergency simply turn the engine switch to the OFF position Under normal conditions use the following procedure Turn the engine switch to the OFF position Allow the engine to cool...

Отзывы: