CONTROLS & FEATURES
28
Voltage Selector Switch
The voltage selector switch switches generator output to produce “120V ONLY”
or “120V/240V.” If a 240V appliance is connected to the 4-prong receptacle, the
switch must be in the “120V/240V” position. If only a 120V appliance is being
connected to any of the 120V 3-prong receptacles, select the “120V ONLY”
position.
Select the voltage before starting the engine.
SWITCH POSITION
120V/240V:
The 120V and 120V/240V receptacles can be used simultaneously.
120V ONLY:
ONLY 120 volts is available in this position; 240 volts is not
available. The most power will be available at the 30A 120V locking plug
receptacle.
VOLTAGE SELECTOR SWITCH
120 V/240 V
120 V ONLY
31Z236200.book 28 ページ 2020年2月20日 木曜日 午後1時8分