background image

9

Gasoline is extremely flammable and
explosive under certain conditions.
Refuel in a well ventilated area with
the engine stopped.
Keep away from cigarette, smoke and
sparks when refueling the generator.
Always refuel in a well ventilated
location.
Wipe up spilled gasoline at once.

A hot exhaust system can cause serious burns.
Avoid contact if the engine has been running.

Stop the engine before refueling.

09/02/23 10:00:25 32Z21600_011

Содержание EM3100CX

Страница 1: ...S Honda OWNER S MANUAL EM3100CX EM4500CX EM5500CX EM4500CXS EM5500CXS The e SPEC mark symbolizes environmentally responsible technologies applied to Honda power equipment which contains our wish to preserve nature for generations to come 09 02 23 09 59 09 32Z21600_001 ...

Страница 2: ...nformation available at the time of approval for printing Honda Motor Co Ltd reserves the right to make changes at any time without notice and without incurring any obligation No part of this publication may be reproduced without written permission This manual should be considered a permanent part of the generator and should remain with it if it is resold Pay special attention to statements preced...

Страница 3: ...OPERATION CHECK 15 STARTING THE ENGINE 19 High altitude operation GENERATOR USE 31 STOPPING THE ENGINE 37 MAINTENANCE 39 TRANSPORTING STORAGE 46 TROUBLESHOOTING 48 SPECIFICATIONS 51 INSTALLATION OF KIT PARTS 57 WIRING DIAGRAM 64 MAJOR Honda DISTRIBUTOR ADDRESSES 70 1 2 3 4 5 6 7 8 9 10 11 12 13 14 09 02 23 09 59 25 32Z21600_004 ...

Страница 4: ...l or do not change the wiring of the control panel Know how to stop the generator quickly in case of emergency Understand the use of all generator controls output receptacles and connections Be sure that anyone who operates the generator receives proper instruction Do not let children operate the generator without parental supervision Do not operate the generator with any cover removed You may get...

Страница 5: ...n if misused Using a generator or electrical appliance in wet conditions such as rain or snow or near a pool or sprinkler system or when your hands are wet could result in electrocution Keep the generator dry If the generator is stored outdoors unprotected from the weather check all of the electrical components on the control panel before each use Moisture or ice can cause a malfunction or short c...

Страница 6: ... stopping the engine Be careful not to touch the muffler while it is hot Let the engine cool before storing the generator indoors Do not pour the water directly on the generator to put out the fire when it occurs Use an appropriate fire extinguisher specially designed for electric fire or oil fire If you inhale fumes produced by an accidental fire with the generator consult a doctor and have medic...

Страница 7: ...of these parts Please dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed container to your local service station for reclamation Do not throw it in the trash or pour it on the ground An improperly disposed battery can hurt the environment Always confirm local regulations for battery disposal Contact your Honda servicing dealer for a rep...

Страница 8: ... CAUTION HOT CAUTION These labels warn you of potential hazards that can cause serious injury Read the labels and safety notes and precautions described in this manual carefully If a label comes off or becomes hard to read contact your Honda dealer for a replacement 09 02 23 10 00 08 32Z21600_009 ...

Страница 9: ...xhaust gas Never run your generator inside a garage house or near open windows or doors Do not connect to a building s electrical system unless an isolation switch has been installed by a qualified electrician Connections for standby power to a building s electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes Improper connections can...

Страница 10: ...engine stopped Keep away from cigarette smoke and sparks when refueling the generator Always refuel in a well ventilated location Wipe up spilled gasoline at once A hot exhaust system can cause serious burns Avoid contact if the engine has been running Stop the engine before refueling 09 02 23 10 00 25 32Z21600_011 ...

Страница 11: ...10 CE mark and noise label locations Example EM5500CXS Manufacturer and address Dry mass IP code Performance class Year of manufacture NOISE LABEL AND CE MARK NOISE LABEL 09 03 24 15 18 39 32Z21600_012 ...

Страница 12: ... PLUG CAP FRAME SERIAL NUMBER FUEL GAUGE OIL FILLER CAP ENGINE SERIAL NUMBER MUFFLER FUSE CXS type STARTER GRIP Frame serial number Engine serial number Record the frame serial number and the engine serial number in the spaces below You will need these serial numbers when ordering parts 09 02 23 10 00 39 32Z21600_013 ...

Страница 13: ... CX type 230 V RECEPTACLE 115 V RECEPTACLES 115 V RECEPTACLES ENGINE SWITCH CIRCUIT BREAKER 230 V RECEPTACLE AUTO THROTTLE SWITCH CXS type AC CIRCUIT PROTECTORS AC CIRCUIT PROTECTORS CIRCUIT BREAKER EM3100CX EM4500CX EM5500CX EM4500CXS EM5500CXS CONTROL PANEL B type 09 02 23 10 00 47 32Z21600_014 ...

Страница 14: ...ER 230 V RECEPTACLES AUTO THROTTLE SWITCH CXS type CX type AC CIRCUIT PROTECTOR ENGINE SWITCH AC CIRCUIT PROTECTORS Except EM3100CX 230 V RECEPTACLES GROUND TERMINAL CIRCUIT BREAKER EM3100CX EM4500CX EM5500CX EM4500CXS EM5500CXS IT type EM5500CXS F G GW types 09 02 23 10 00 54 32Z21600_015 ...

Страница 15: ...ed speed Recommended to minimize fuel consumption and further reduce noise levels when no load is applied to the generator The Auto Throttle system does not operate Recommended to minimize warm up time when the generator is started Leave the switch in the OFF position when using appliances that require only momentary power that have a power demand of less than 1 ampere or that have large startup p...

Страница 16: ...l level regularly SAE 10W 30 is recommended for general all temperature use Other viscosities shown in the chart may be used when the average temperature in your area is within the indicated range If the oil level is low fill to the upper limit of the oil filler neck with the recommended oil Remove the oil filler cap and wipe the dipstick clean Check the oil level by inserting the dipstick in the ...

Страница 17: ... not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored Gasoline is extremely flammable and is explosive under certain conditions FULL EMPTY FUEL GAUGE FUEL TANK CAP UPPER LEVEL MARK RED FUEL STRAINER UPPER LEVEL MARK RED Check the fuel level Check the fuel gauge If the fuel level is low refuel the fuel tank until the level as specified After refue...

Страница 18: ...you know does not contain alcohol Before buying fuel from an unfamiliar station try to find out if the fuel contains alcohol if it does confirm the type and percentage of alcohol used Honda cannot endorse the use of fuels containing methanol since evidence of their suitability is as yet incomplete Fuel system damage or engine performance problems resulting from the use of fuels that contain alcoho...

Страница 19: ...the carburetor into the engine ELEMENT AIR CLEANER COVER CLIP Check the air cleaner Clean or replace the element if necessary see page Unsnap the two air cleaner cover clips remove the air cleaner cover and remove the air cleaner element Check the air cleaner element to be sure it is clean and in good condition 3 41 09 02 23 10 01 44 32Z21600_020 ...

Страница 20: ...19 STARTING THE ENGINE 5 O OF FF F CIRCUIT BREAKER O OF FF F Make sure that the circuit breaker is OFF The generator may be hard to start if a load is connected 09 02 23 10 01 48 32Z21600_021 ...

Страница 21: ...the fuel valve lever to the ON position then wait for 10 to 20 seconds before starting the engine CXS type VOLTAGE SELECTOR SWITCH FUEL VALVE LEVER O OF FF F ON 115 V 230 V Set the Voltage Selector Switch to match the voltage requirements for the application Turn the fuel valve lever to the ON position 1 2 B type 09 02 23 10 01 56 32Z21600_022 ...

Страница 22: ...ROTTLE SWITCH OFF OFF AUTO THROTTLE SWITCH O OF FF F F G GW IT types B type OFF Make sure the auto throttle switch is in the OFF position or more time will be required for warm up 3 09 02 23 10 02 01 32Z21600_023 ...

Страница 23: ...N START ENGINE SWITCH ON START OFF O OF FF F Turn the engine switch to the START position and hold it there for 5 seconds or until the engine starts After the engine starts let the engine switch return to the ON position When the speed of the starter motor drops after a period of time it is an indication that the battery should be recharged 4 09 02 23 10 02 08 32Z21600_024 ...

Страница 24: ... AUTO THROTTLE SWITCH ON O ON N F G GW IT types B type If you wish to use the auto throttle system turn the auto throttle switch to the ON position after the engine has warmed up for 2 or 3 minutes 5 09 02 23 10 02 13 32Z21600_025 ...

Страница 25: ...ve lever to the ON position then wait for 10 to 20 seconds before starting the engine Manual starting VOLTAGE SELECTOR SWITCH FUEL VALVE LEVER O OF FF F ON 115 V 230 V Set the Voltage Selector Switch to match the voltage requirements for the application Turn the fuel valve lever to the ON position 1 2 B type 09 02 23 10 02 20 32Z21600_026 ...

Страница 26: ...if the engine is cold If you want to operate the choke manually pull the choke rod out to the CLOSED position Pull the choke rod to the CLOSED position to start a cold engine Push the choke rod in the OPEN position to start a warm engine CX type CXS type 3 09 02 23 10 02 26 32Z21600_027 ...

Страница 27: ...E SWITCH OFF OFF AUTO THROTTLE SWITCH OFF O OF FF F F G GW IT types B type Make sure the auto throttle switch is in the OFF position or more time will be required for warm up 4 CXS type 09 02 23 10 02 31 32Z21600_028 ...

Страница 28: ...27 CX type CXS type ENGINE SWITCH ON OFF ENGINE SWITCH ON O OF FF F ON O OF FF F ON OFF Turn the engine switch to the ON position 5 09 02 23 10 02 37 32Z21600_029 ...

Страница 29: ...efore you release it This may pull your hand forcefully toward the engine and cause an injury CHOKE ROD O OP PE EN N STARTER GRIP D Di ir re ec ct ti io on n t to o p pu ul ll l Pull the starter grip lightly until you feel resistance then pull the starter grip briskly toward in the direction of the arrow as shown below Push the choke rod to the OPEN position as the engine warms up 6 7 09 02 23 10 ...

Страница 30: ...O THROTTLE SWITCH ON O ON N F G GW IT types B type If you wish to use the auto throttle system turn the auto throttle switch to the ON position after the engine has warmed up for 2 or 3 minutes 8 CXS type 09 02 23 10 02 50 32Z21600_031 ...

Страница 31: ...tion will increase High altitude performance can be improved by specific modifications to the carburetor If you always operate the generator at altitudes higher than 1 500 meters 5 000 feet above sea level have your authorized Honda dealer perform these carburetor modifications Even with suitable carburetor jetting engine horsepower will decrease approximately 3 5 for each 300 meter 1 000 foot inc...

Страница 32: ...cified for any one receptacle Do not connect the generator to a household circuit This could cause the damage to the generator or to electrical appliances in the house Do not modify or use the generator for other purposes than it is intended for Also observe the following when using the generator When an extension cable is required be sure to use a tough rubber sheathed flexible cable IEC 245 or e...

Страница 33: ...may not switch the circuit breaker or DC circuit protector OFF but will shorten the service life of the generator Limit operation requiring maximum power to 30 minutes Maximum power is 3 1 kVA 4 5 kVA 5 5 kVA For continuous operation do not exceed the rated power Rated power is 2 8 kVA 4 0 kVA 5 0 kVA In either case the total power requirements VA of all appliances connected must be considered Mos...

Страница 34: ...engine switch immediately Then disconnect the appliance and examine it for signs of malfunction VOLTAGE SELECTOR SWITCH 230 V 115V ON CIRCUIT BREAKER ON Set the Voltage Selector Switch to match the voltage requirements for the appliance Switch the circuit breaker ON Start the engine see page Most motorized appliances require more than their rated power for startup Confirm that the appliance to be ...

Страница 35: ...atically switch OFF push button comes out if there is a short circuit or a significant overload of the generator at receptacle If an AC circuit protector switches OFF automatically check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON pushing the push button in Except EM3100CX F G types 09 02 23 10 03 29...

Страница 36: ...pt EM3100CX AC CIRCUIT PROTECTOR For receptacle No 2 RECEPTACLE No 1 RECEPTACLE No 2 AC CIRCUIT PROTECTOR For receptacle No 1 IT type AC CIRCUIT PROTECTOR For receptacle No 1 RECEPTACLE No 1 09 02 23 10 03 34 32Z21600_037 ...

Страница 37: ...ankcase Before the oil level in the crankcase falls below a safe limit the Oil Alert system will automatically shut down the engine the engine switch will remain in the ON position If the engine stops and will not restart check the engine oil level see page before troubleshooting in other areas 15 09 02 23 10 03 39 32Z21600_038 ...

Страница 38: ...S type O OF FF F O OF FF F CIRCUIT BREAKER ON ON ON ON O OF FF F ON OFF Turn the engine switch to the OFF position Turn the circuit breaker to the OFF position To stop the engine in an emergency turn the engine switch to the OFF position 1 2 09 02 23 10 03 49 32Z21600_039 ...

Страница 39: ...38 OFF FUEL VALVE LEVER ON Turn the fuel valve lever to the OFF position 3 09 02 23 10 03 52 32Z21600_040 ...

Страница 40: ...nance and adjustment schedule is to keep the generator in the best operating condition Inspect or service as scheduled in the table below For commercial use log hours of operation to determine proper maintenance intervals These items should be serviced by your Honda servicing dealer unless you have the proper tools and are mechanically proficient Refer to the Honda shop manual for service procedur...

Страница 41: ...oil see page and check the oil level Wash your hands with soap and water after handling used oil Please dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed container to your local service station for reclamation Do not throw it in the trash or pour it on the ground Drain the oil while the engine is still warm to assure rapid and complete...

Страница 42: ...gularly Service more frequently when operating the generator in extremely dusty areas Reinstall the air cleaner element and the cover Soak the air cleaner element in clean engine oil and squeeze out the excess oil The engine will smoke during initial startup if too much oil is left in the air cleaner element Wash the air cleaner element in a solution of household detergent and warm water then rins...

Страница 43: ...MENT CUP O RING OFF FILTER The sediment cup prevents dirt or water that may be in the fuel tank from entering the carburetor If the engine has not been run for a long time the sediment cup should be cleaned Turn the fuel valve lever to the OFF position Remove the sediment cup O ring and filter Reinstall the filter O ring and sediment cup Turn the fuel valve lever to the ON position and check for l...

Страница 44: ...lug must be properly gapped and free of deposits Remove the spark plug cap Clean any dirt from around the spark plug base Use a spark plug wrench to remove the spark plug Visually inspect the spark plug Discard it if the insulator is cracked chipped or fouled Clean the spark plug with a wire brush if it is to be reused 0 7 0 8 mm 0 028 0 031 in Measure the plug gap with a feeler gauge Correct as n...

Страница 45: ...ter the spark plug seats to compress the washer If reinstalling a used spark plug tighten 1 8 to 1 4 turn after the spark plug seats Make sure that the sealing washer is in good condition and thread the spark plug in by hand to prevent cross threading After the spark plug is seated tighten with a spark plug wrench to compress the washer Reinstall the spark plug cap on the spark plug securely 6 7 8...

Страница 46: ...ure occurs determine the cause and correct the problem before attempting to operate the generator further 5 CXS type FUSE HOLDER COVER If the fuse is blown the starter motor will not work until it is replaced Turn the engine switch to the OFF position Remove the fuse holder cover and replace the fuse The specified fuse is 10A 1 2 09 02 23 10 05 08 32Z21600_047 ...

Страница 47: ... not operate the generator while it is on a vehicle Take the generator off the vehicle and use it in a well ventilated place Do not overfill the tank When transporting the generator Transporting 9 When transporting the generator by loading it on to a vehicle secure to the generator frame as shown Take care not to drop or strike the generator when transporting Do not place heavy object on the gener...

Страница 48: ... the gasoline into a suitable container Change the engine oil refer to page Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder Turn the engine several revolutions slowly with the recoil starter to distribute the oil then reinstall the spark plug Slowly pull the starter grip until resistance is felt At this point the piston is coming up on its compression stroke...

Страница 49: ...ine switch and loosen the drain screw see page To check Is the fuel reaching the carburetor Clean the fuel sediment cup see page Is the spark plug in good condition Clean readjust gap and dry the spark plug Replace it if necessary see page Is there enough oil in the engine Add the recommended oil see page Is the engine switch ON Turn the engine switch on see page for electric starting or for manua...

Страница 50: ...n round Is the battery discharged Is the fuse blown Replace the fuse see page Charge the battery If the starter motor still does not turn round take the generator to an autorized Honda dealer NO NO YES YES 45 09 02 23 10 05 48 32Z21600_051 ...

Страница 51: ...uipment Take the electrical appliance or equipment to an electrical shop for repair Is the AC circuit protector ON Reset the AC circuit protector see page Check the electrical appliance or equipment for any defects Take the generator to an authorized Honda generator dealer NO NO DEFECTS DEFECTS YES 33 YES 34 NO 09 02 23 10 05 56 32Z21600_052 ...

Страница 52: ... 2 lbs GX240 4 stroke overhead valve single cylinder 242 cm 14 8 cu in 73 0 58 0 mm 2 87 in 2 28 in 8 2 1 Forced air Transistorized magneto W16EPR U DENSO BPR5ES NGK EM3100CX B 50 24 3 12 2 2 8 115 230 F G 230 12 2 3 1 3 000 rpm 1 1 L 1 2 US qt 1 0 lmp qt 23 5 L 6 21 US gal 5 17 lmp gal Model Description code Length Width Height Dry mass weight Model Type AC output Rated Voltage V Rated Frequency ...

Страница 53: ...ssion and exposure levels this cannot be used reliably to determine whether or not further precautions are required Factors that influence the actual level of exposure of work force include the characteristics of the work room the other sources of noise etc i e the number of machines and other adjacent processes and the length of time for which an operator is exposed to the noise Also the permissi...

Страница 54: ... in 8 0 1 Forced air Transistorized magneto BPR5ES NGK W16EPR U DENSO EM4500CX EM4500CXS EATC 877 mm 34 5 in 530 mm 20 9 in 546 mm 21 5 in 546 mm 21 5 in 95 3 kg 210 1 lbs EM4500CX EM4500CXS B 115 230 50 34 8 17 4 4 0 F G GW 230 17 4 87 8 kg 193 6 lbs 4 5 3 000 rpm 1 1 L 1 2 US qt 1 0 lmp qt 23 5 L 6 21 US gal 5 17 lmp gal Model Description code Length Width Height Dry mass weight Model Type AC ou...

Страница 55: ...he emission and exposure levels this cannot be used reliably to determine whether or not further precautions are required Factors that influence the actual level of exposure of work force include the characteristics of the work room the other sources of noise etc i e the number of machines and other adjacent processes and the length of time for which an operator is exposed to the noise Also the pe...

Страница 56: ... cm 23 7 cu in 88 0 64 0 mm 3 46 in 2 52 in 8 0 1 Forced air Transistorized magneto BPR5ES NGK W16EPR U DENSO EM5500CX EM5500CXS B 115 230 50 43 5 21 7 5 0 F G GW IT 230 21 7 EM5500CXS EAVC 877 mm 34 5 in 530 mm 20 9 in 546 mm 21 5 in 97 6 kg 215 2 lbs 5 5 3 000 rpm 1 1 L 1 2 US qt 1 0 lmp qt 23 5 L 6 21 US gal 5 17 lmp gal Model Description code Length Width Height Dry mass weight Model Type AC o...

Страница 57: ...d reliably to determine whether or not further precautions are required Factors that influence the actual level of exposure of work force include the characteristics of the work room the other sources of noise etc i e the number of machines and other adjacent processes and the length of time for which an operator is exposed to the noise Also the permissible exposure level can vary from country Thi...

Страница 58: ...E positive CABLE TIE Unscrew the four 6 10 mm flange bolts and remove the side panel Route the starter cable under the tank and connect it to the starter solenoid Connect the ground cable to the generator Pass the starter cable and the ground cable through the slots on the side panel Reinstall the side panel using the four 6 10 mm flange bolts 1 2 3 4 5 09 02 23 10 07 33 32Z21600_059 ...

Страница 59: ...ing the four 8 12 mm flange bolts Install the battery tray on the battery guards using the four 8 40 mm flange bolts Set the battery on the battery tray and secure with the battery bracket Connect the starter cable to the battery positive terminal first then to the negative terminal When disconnecting disconnect at the battery negative terminal first Install the battery guard plate using the four ...

Страница 60: ...28 mm SPLIT PIN 2 8 mm FLANGE NUT 4 24 29 N m 2 4 3 0 kgf m 17 22 lbf ft Install the right and left handles on the generator upper frame using the handle brackets and four flange bolts Install the axle assembly on the generator using four 8 16 mm flange bolts and 8 mm flange nuts Install the two stands on the under frame using four 8 16 mm flange bolts Apply grease to the axle shaft as shown below...

Страница 61: ...FT 8 16 mm FLANGE BOLT 8 24 29 N m 2 4 3 0 kgf m 17 22 lbf ft Install the left wheel shaft on the left side nearest the engine Install the lock plate and four wheels on the wheel shaft using the washers and split pins Install the wheel shaft assembly on the generator using eight 8 16 mm flange bolts and 8 mm flange nuts 1 2 09 02 23 10 08 03 32Z21600_062 ...

Страница 62: ...6 mm FLANGE BOLT 4 280 mm 11 in Position the hanger at the generator s balance point as shown below Fit the end tabs of the hanger through the bracket slots and bolt the brackets to the hanger and tighten securely 24 29 N m 2 4 3 0 kgf m 17 22 lbf ft 1 2 09 02 23 10 08 10 32Z21600_063 ...

Страница 63: ...Unscrew the four 6 10 mm flange bolts and remove the side panel Reinstall the side panel using the four 6 10 mm flange bolts Pass the remote control cable through the cord grommet and fit the grommet into the cutout Connect the remote control cable to the 6 pin connector Remove the plug from the 6 pin connector 1 2 3 4 5 09 02 23 10 08 19 32Z21600_064 ...

Страница 64: ...urn the engine switch to the OFF position Press the stop switch Stopping the engine with remote control Press the start switch untill the pilot lamp comes on Turn the engine switch to the ON position Turn the fuel valve to the ON position Starting the engine with remote control Connect the blind connector when not using the remote control Engine will not start unless the blind connector is connect...

Страница 65: ...hrottle Unit Auto Voltage Regulator Battery Circuit Breaker Control Box Block Charge Coil Diode DC Winding Engine Block Engine Control Unit Engine Switch Fuse Exciter Winding Field Winding Fuel Cut Solenoid Generator Block Ground Terminal Ignition Coil Main Winding Oil Alert Unit Oil Level Switch Remote Control Block Remote Control Cable Starter Spark Plug Start Switch Stop Switch Solenoid Valve T...

Страница 66: ...g P Gr BLACK YELLOW BLUE GREEN RED WHITE BROWN ORANGE LIGHT BLUE LIGHT GREEN PINK GRAY ENGINE SWITCH EM3100CX EM4500CX EM5500CX EM4500CXS EM5500CXS OFF ON OFF ON START IG E FS G IG E FS G LO BAT ST 09 02 23 10 08 41 32Z21600_067 ...

Страница 67: ...66 EM3100CX EM4500CX EM5500CX B type 09 02 23 10 08 48 32Z21600_068 ...

Страница 68: ...67 EM4500CXS EM5500CXS B type 09 02 23 10 08 58 32Z21600_069 ...

Страница 69: ...68 EM3100CX EM4500CX EM5500CX F G GW types 09 02 23 10 09 05 32Z21600_070 ...

Страница 70: ...69 EM4500CXS EM5500CXS F G GW IT types 09 02 23 10 09 15 32Z21600_071 ...

Страница 71: ...e 166 63069 Offenbach am Main Tel 49 69 8300 60 Fax 49 69 8300 65100 http www honda de info post honda de TSA 80627 45146 St Jean de la Ruelle CEDEX Tel 02 38 81 33 90 Fax 02 38 81 33 91 http www honda fr relationsclientele produits equipement honda eu com 71 Leoforos Athinon 10173 Athens Tel 30 210 349 7809 Fax 30 210 346 7329 http www honda gr info saracakis gr Kamaraerdei ut 3 2040 Budaors Tel ...

Страница 72: ...an Gwakkin Road Mriehel Bypass Mriehel QRM17 Tel 356 21 498 561 Fax 356 21 480 150 Kubiliaus str 6 08234 Vilnius Tel 370 5 276 5259 Fax 370 5 276 5250 http www hondapower lt Crosslands Business Park Ballymount Road Dublin 12 Tel 353 01 460 2111 Fax 353 01 456 6539 http www hondaireland ie sales hondaireland ie Via della Cecchignola 5 7 00143 Roma Tel 848 846 632 Fax 39 065 4928 400 http www hondai...

Страница 73: ... Str Build 2 Kiev 01033 Tel 380 44 390 1414 Fax 380 44 390 1410 http www honda ua Esentepe mah Anadolu Cad No 5 Kartal 34870 Istanbul Tel 90 216 389 59 60 Fax 90 216 353 31 98 http www anadolumotor com tr antor antor com tr Carretera General del Sur KM 8 8 38107 Santa Cruz de Tenerife Tel 34 922 620 617 Fax 34 922 618 042 http www aucasa com ventas aucasa com taller aucasa com Box 50583 Västkustvä...

Отзывы: