Honda EG2800i Скачать руководство пользователя страница 3

3

Early symptoms of carbon monoxide exposure include headache, 
fatigue, shortness of breath, nausea, and dizziness. Continued 
exposure to carbon monoxide can cause loss of muscular 
coordination, loss of consciousness, and then death.

Electric Shock Hazards

• The generator produces enough electric power to cause a serious 

shock or electrocution if misused.

• Using a generator or electrical appliance in wet conditions, such as 

rain or snow, or near a pool or sprinkler system, or when your hands 
are wet, could result in electrocution. Keep the generator dry.

• If the generator is stored outdoors, unprotected from the weather, 

check all of the electrical components on the control panel before 
each use. Moisture or ice can cause a malfunction or short circuit in 
electrical components that could result in electrocution.

• Do not connect to a building's electrical system unless an isolation 

(transfer) switch has been installed by a qualified electrician.

Fire and Burn Hazards

• The exhaust system gets hot enough to ignite some materials.

– Keep the generator at least 3 feet (1 meter) away from buildings 

and other equipment during operation.

– Do not enclose the generator in any structure.
– Keep flammable materials away from the generator.

• The muffler becomes very hot during operation and remains hot for 

a while after stopping the engine. Be careful not to touch the muffler 
while it is hot. Let the engine cool before storing the generator 
indoors.

Refuel With Care

• Gasoline is extremely flammable, and gasoline vapor can explode.
• Do not refuel during operation.
• Allow the engine to cool if it has been in operation.
• Refuel only outdoors in a well-ventilated area and on a level surface. 
• Never smoke near gasoline, and keep other flames and sparks 

away. 

• Do not overfill the fuel tank. Overfilling the fuel tank may cause fuel 

to leak out of the bottom of the EVAP canister.

• Make sure that any spilled fuel has been wiped up before starting 

the engine.

• Always store gasoline in an approved container.

Safety Label Locations

These labels warn you of potential hazards that can cause serious 
injury. Read them carefully. If a label comes off or becomes hard to 
read, contact an authorized Honda servicing dealer for a replacement. 

Содержание EG2800i

Страница 1: ...Air Index 16 Controls 6 Air Cleaner 12 Specifications 16 Features 6 Spark Plug 12 Wiring Diagram 17 OPERATION 7 Sediment Cup Cleaning 13 AVOIDING FUEL RELATED PROBLEMS 18 Safe Operating Instructions 7...

Страница 2: ...table power requirements Other uses can result in injury to the operator or damage to the generator and other property Most injuries or property damage can be prevented if you follow all the instructi...

Страница 3: ...ignite some materials Keep the generator at least 3 feet 1 meter away from buildings and other equipment during operation Do not enclose the generator in any structure Keep flammable materials away f...

Страница 4: ...ctane rating of 86 or higher containing no more than 10 ethanol E10 or 5 methanol by volume Refer to page 11 for additional fuel recommendations 1 Remove the fuel tank cap 2 Add fuel slowly to prevent...

Страница 5: ...for signs of damage Check each control for proper operation Check that all nuts bolts and screws are tightened Check the air filter page 12 and oil level page 11 Check the fuel level page 7 Starting w...

Страница 6: ...OFF position to reduce voltage changes ON Recommended to minimize fuel consumption and further reduce noise levels when less than a full load is applied to the generator OFF The Eco Throttle system d...

Страница 7: ...ings and other equipment Do not operate the generator in an enclosed structure Do not place flammable objects close to the engine or locate the generator near flammable materials Starting the Engine T...

Страница 8: ...wer cord can create a potential for electrical shock If an appliance begins to operate abnormally becomes sluggish or stops suddenly turn it off immediately Disconnect the appliance and determine whet...

Страница 9: ...able to your individual needs and use Remember that an authorized Honda servicing dealer knows your generator best and is fully equipped to maintain and repair it To ensure the best quality and reliab...

Страница 10: ...able failures Item Action Before each use 5 hours of use or first month 25 hours of use or every 3 months 50 hours of use or every 6 months 100 hours of use or every year 250 hours of use or every 2 y...

Страница 11: ...e DISTRIBUTOR S LIMITED WARRANTY If your equipment will be used on an infrequent or intermittent basis please refer to the fuel section of the STORAGE chapter page 13 for additional information regard...

Страница 12: ...inside Never try to brush off dirt brushing will force dirt into the fibers 5 Foam Air Filter Wash the foam air filter in a solution of household detergent and warm water then rinse thoroughly or wash...

Страница 13: ...el Position the generator so that its base is level on the bed of the transport vehicle Tie the generator down with rope or straps Keep the tie down rope or straps away from the controls Do not operat...

Страница 14: ...cover A nonporous cover will trap moisture around the generator promoting rust and corrosion Removing from Storage Check your generator as described in BEFORE EACH USE on page 5 If the engine cylinder...

Страница 15: ...ontrol systems to reduce the emissions of carbon monoxide oxides of nitrogen and hydrocarbons Additionally Honda fuel systems utilize components and control technologies to reduce evaporative emission...

Страница 16: ...tended 300 hours 0 80 cc 500 hours greater than 80 cc 1000 hours 225 cc and greater EG2800i Lightweight inverter generator with Eco Throttle Length 16 9 in 430 mm Width 17 6 in 448 mm Overall height 1...

Страница 17: ...17 Wiring Diagram...

Страница 18: ...k it before each use A properly maintained air filter will help prevent dirt from entering the carburetor The small passages inside the carburetor can become blocked 3 to 4 Weeks Before Next Use Reaso...

Страница 19: ...detailed description of the problem Honda Publications These publications will give you information for maintaining and repairing your generator Owner s Manual Keep this owner s manual handy so you c...

Страница 20: ...w limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above exclusions and limitations may not apply to you...

Страница 21: ...place other engine components damaged by a failure of any warranted part during the warranty period The use of replacement parts not equivalent to the original parts may impair the effectiveness of yo...

Страница 22: ...22 NOTES...

Страница 23: ...ne Complete and mail the postage paid card shown below Complete and submit the on line form at powerequipment honda com Scan the QR code below and then complete and submit the on line form commercial...

Страница 24: ...ick Submit It s that simple Power Equipment Division American Honda Motor Co Inc 4900 Marconi Dr Alpharetta GA 30005 9956 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES Product Registration BUSIN...

Отзывы: