38
OPERATION
AC Receptacle Selection
The control panel, shown below, has a voltage selector switch and
four receptacles. Receptacle 4, the 240-volt receptacle, has two
powered terminals, 4A and 4B.
Power Producing Circuits
This generator is equipped with two power generating circuits.
When the voltage selector switch is in the 120V/240V position, each of
the two power producing circuits supplies power to specific
receptacles.
When the voltage selector switch is in the 120V ONLY position, the
power producing circuits operate in parallel, sharing the total load
connected to terminal 4A and receptacles 1, 2, and 3.
*
TERMINAL
VOLTAGE SELECTOR
SWITCH
RECEPTACLE
②
GFCI RECEPTACLES
(120 V 20 A DUPLEX RECEPTACLE)
RECEPTACLE
③
GFCI RECEPTACLES
(120 V 20 A DUPLEX RECEPTACLE)
<EB4000X>
RECEPTACLE
④
TERMINAL
TERMINAL
RECEPTACLE
①
TERMINAL
RECEPTACLE
④
*: Except EB4000X
POWER CIRCUIT A
120 V/240 V
120 V ONLY
POWER
CIRCUIT B
POWER
CIRCUIT A
POWER CIRCUIT B