GP 2500A

Maintenance

27

3.3

Engine Oil

3.3.1

Drain the oil while the engine is still warm.

3.3.2

Remove the oil filler plug (a) and the drain plug (b) to drain the oil.

Note: 

In the interests of environmental protection, place a plastic sheet

and a container under the machine to collect any liquid that drains off.
Dispose of this liquid in accordance with environmental protection
legislation.

3.3.3

Install the drain plug.

3.3.4

Fill the engine crankcase with the recommended oil up to the level of
the plug opening (c). See section 

Technical Data

 for oil quantity and

type.

3.3.5

Install the oil filler plug.

wc_gr000022

Содержание 0620128

Страница 1: ...Generator GP 2500A OPERATOR S MANUAL 0163727en 005 0509 0 1 6 3 7 2 7 E N...

Страница 2: ...enclosed areas Deadly levels of carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outside and far away from wi...

Страница 3: ...perating instructions carefully If you have questions about operating or servicing this equipment please contact Wacker Neuson Corporation The information contained in this manual was based on machine...

Страница 4: ...wc_tx000001gb fm 4...

Страница 5: ...vice Safety 11 1 5 Label Locations 12 1 6 Safety and Operating Labels 13 2 Operation 17 2 1 Determining Power Requirements 17 2 2 Installation 18 2 3 Generator Derating 19 2 4 Grounding the Generator...

Страница 6: ...Schedule 26 3 3 Engine Oil 27 3 4 Servicing Air Cleaner 28 3 5 Spark Plug 29 3 6 Cleaning the Sediment Cup 30 3 7 Carburetor Adjustment 31 3 8 Adjusting Engine Speed 32 3 9 Storage 32 3 10 Transport 3...

Страница 7: ...tuation which if not avoided could result in minor or moderate injury NOTICE Used without the safety alert symbol NOTICE indicates a situation which if not avoided could result in property damage Note...

Страница 8: ...ents may exist and improper connection may lead to equipment damage fire and personal injury or death Familiarity and proper training are required for the safe operation of the machine Machines operat...

Страница 9: ...generator on a firm noncombustible level surface 1 2 14 ALWAYS transport the generator in an upright position 1 2 15 ALWAYS keep the machine at least one meter three feet away from structures buildin...

Страница 10: ...cannot see or smell 1 3 2 NEVER use a generator inside an enclosed area such as a tunnel or a trench 1 3 3 Do not smoke while operating the machine 1 3 4 Do not smoke when refueling the engine 1 3 5 D...

Страница 11: ...chine and allow the machine to dry before servicing 1 4 5 DO NOT service the machine if your clothing or skin is wet 1 4 6 DO NOT allow untrained personnel to service this equipment Only trained elect...

Страница 12: ...Safety Information GP 2500A 12 1 5 Label Locations GND 88897 1 1 2 2 3 4 5 6...

Страница 13: ...ng objects near machine Shut off the engine before refueling WARNING Hot surface DANGER Asphyxiation hazard Read the Operator s Manual for instructions Using a generator indoors CAN KILL YOU IN MINUTE...

Страница 14: ...ctrical current from the generator to backfeed into utility lines This may result in electrocution of utility workers fire or explosion Connections to a building s electrical system must be made by a...

Страница 15: ...fety Information 15 Open the fuel flow valve Close the choke Turn the engine switch to the ON position Pull the rewind starter Open the choke Turn the engine switch to OFF Close the fuel flow valve La...

Страница 16: ...nd serial number is attached to each unit Please record the information found on this plate so it will be available should the nameplate become lost or damaged When ordering parts or requesting servic...

Страница 17: ...the power required to keep it running The generator must be capable of supplying this surge current Other types of appliances require more power than is actually stated on their nameplate The informat...

Страница 18: ...re Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use this generator inside a home or garage EVEN IF doors...

Страница 19: ...ffects the cooling capacity of air the higher the altitude the less dense the air is and thus the lower its ability to transfer heat For every increase in altitude of 500 m 1650 ft above 1000 m 3300 f...

Страница 20: ...This ground connection must comply with National Electrical Code standards and state and local regulations 2 5 Operating Heavy Loads Limit operations requiring the maximum rated output of 2600 Watts t...

Страница 21: ...d extension cords can cause electrical shock resulting in serious injury or death DO NOT use worn bare or frayed cords Replace damaged cords immediately Use the chart below as a guide for selecting pr...

Страница 22: ...tion GP 2500A 22 2 7 Control Panel Ref Description Ref Description a GFI duplex receptacle 120V d GFI test button b Circuit breaker 20 Amp e GFI reset button c Duplex receptacle 120V f Engine ON OFF s...

Страница 23: ...not run generator until the problem can be corrected To restore power to receptacle push the RESET button in If the RESET button pops out during operation stop the generator and check it and equipment...

Страница 24: ...n of air cleaner tightness of external fasteners condition of fuel lines Note The engine is equipped with an oil alert system If the oil level in the engine drops too low the engine will not start 2 1...

Страница 25: ...e open position b1 2 11 4 Turn the engine switch to ON c1 2 11 5 Pull the starter rope d Note If the oil level in the engine is low the red LED at the engine switch will light and the engine will not...

Страница 26: ...20 hrs Every 50 hrs Every 100 hrs Every 300 hrs Check the fuel level Check the engine oil level Inspect the air filter Replace as needed Check external hardware Clean the air cleaner element Inspect t...

Страница 27: ...otection place a plastic sheet and a container under the machine to collect any liquid that drains off Dispose of this liquid in accordance with environmental protection legislation 3 3 3 Install the...

Страница 28: ...w flash point solvents for cleaning the air cleaner A fire or explosion could result To service 3 4 1 Remove the air cleaner cover a Inspect the element b for holes or tears Replace the element if it...

Страница 29: ...touch the muffler while it is hot Note Refer to section Technical Data for the recommended spark plug type and the electrode gap setting 3 5 1 Remove the spark plug and inspect it 3 5 2 Replace the sp...

Страница 30: ...the Sediment Cup 3 6 1 Turn the fuel valve off 3 6 2 Remove the sediment cup a and the O ring b 3 6 3 Wash both thoroughly in a nonflammable solvent Dry and reinstall them 3 6 4 Turn the fuel valve on...

Страница 31: ...7 4 After the pilot screw is adjusted turn the throttle stop screw b to obtain the standard idle speed See Technical Data Note On some engines the pilot screw is fitted with a limiter cap c to prevent...

Страница 32: ...up or fuel strainer 3 9 2 Disconnect the fuel line from the carburetor Place the open end of the fuel line into a suitable container and open the fuel valve to drain the fuel from the tank Gasoline is...

Страница 33: ...3 11 Troubleshooting Problem Symptom Reason Remedy If engine doesn t start check that Engine switch is on Start Fuel valves under fuel tank and on engine are open Fuel tank has fuel Choke lever is in...

Страница 34: ...W White Gr Gray LL Light blue Ref Description Ref Description Ref Description A Generator B Control Box C Engine Ref Description Ref Description 1 Main stator winding 7 Duplex receptacle 120V 2 Secon...

Страница 35: ...GP 2500A Maintenance 35 8 11 9 10...

Страница 36: ...tinuous Output W 2250 Type Single voltage single phase Auto voltage regulator system AC Voltages Available volts phase 120 1 Frequency Hz 60 Power Factor 1 0 AC receptacles 125V GFI duplex 125V duplex...

Страница 37: ...m rated power at rated speed kW Hp 3 6 4 8 3600 rpm Spark Plug BPR6ES W20EPR U Electrode Gap mm in 0 7 0 8 0 028 0 031 Operating Speed rpm 3600 Air Cleaner type Dry type with oil wetted foam pre clean...

Страница 38: ...2 390 Wacker Neuson Corporation P O Box 9007 Menomonee Falls WI 53052 9007 Tel 262 255 0500 Fax 262 255 0550 Tel 800 770 0957 Wacker Neuson Limited Room 1701 03 1717 20 17 F Tower 1 Grand Century Plac...

Отзывы: