17
GENERATOR USE
RECEPTACLE No.4
RECEPTACLE No.2
RECEPTACLE No.1
RECEPTACLE No.3
RECEPTACLE No.5
LDH type
Receptacle No.4 and No.5 comprise one
240V receptacle with two powered
terminals.
This generator is equipped with two
power generating circuits. When the
voltage selector switch is in the 120V/
240V position, each of the two power
producing circuits supplies power to
specific receptacles.
When the voltage selector switch is in the 120V/240V position, you
must balance the load. Divide the load between the two sets of
receptacles.
When the voltage selector switch is in
the 120V only position, you do not need
to spread the load over the receptacles.
Make sure the load on any receptacle
does not exceed its available power
shown below and the total load does not
exceed the total current available.
Total Current Available:
30 A
20 A
20 A
20 A
30.0 A
37.5 A
45.8 A
15.0 A
18.8 A
22.9 A
Available power
Receptacles
1
2
3
4
5
None
(EG4000CX)
(EG5000CX)
(EG6500CX·EG6500CXS)
(EG4000CX)
(EG5000CX)
Set of Receptacles
Total Current Available
(EG6500CX·
EG6500CXS)
1
3
4
2
5
+ +
+
When the voltage selector switch is in the 120V/240V position, you
must balance the load. Divide the load between the two sets of
receptacles.
15.0 A
18.8 A
22.9 A
(EG4000CX)
(EG5000CX)
Set of Receptacles
Total Current Available
(EG6500CX·
EG6500CXS)
1
3
4
2
5
LD1H type
Receptacles
Available power
EG4000CX
EG5000CX
EG6500CX·EG6500CXS
1
30 A
30 A
30 A
2
20 A
20 A
20 A
3
20 A
20 A
20 A
4
20 A
30 A
30 A
5
None
None
None
5
4
00X4M-Z30-6020̲EG4000̲5000̲6500̲EN.indd 17
00X4M-Z30-6020̲EG4000̲5000̲6500̲EN.indd 17
2014/08/20 18:58:49
2014/08/20 18:58:49