Maintenance 

 
The unit will drain automatically 20 minutes after use.  
Clean the steam generator every 60 uses, and 30 if on well water. 

1.

 

Wait for the completion of automatic water discharge after each use of the steam engine to make sure the 
water in the tank is discharged completely before cutting off power supply.   

 

2.

 

There should not be any leaking or damage to the steam engine, steam nozzle, components and pipes. They 
should be checked monthly.  

 

3.

 

Clean the water supply pipes of the steam engine once a year.  

 

4.

 

Check all the connections, water, and electric, to see if they have become loose or are damaged due to 
overheating.   

 

Steam Generator Cleaning 

 
MAKE SURE POWER IS OFF  

If you can observe that the steam generator is draining after use, this means the tank is not clogged with debris or other 
material from use. The tank cleaning procedure is not too difficult.  
 
You must introduce the citric acid solution into the tank. 6- and 9-Kw units have a 1.5-gal tank, the 12Kw has a 3.2-gal 
tank. This can be done by disconnecting the steam line and with a funnel and hose pour the solution into the tank. If the 
steam line cannot be disconnected you can unscrew the pressure relief valve and pour the solution in through the 
opening. Both openings go to the tank. Fill the tank until the solution starts to come out of the steam outlet or the 
pressure relief valve opening. Replace the steam line or the pressure relief valve, then turn on the steam generator and 
let it produce steam for about one minute, then shut it off at the circuit breaker and let sit for an hour or overnight. 
Then restart the generator and let it run for about 5 minutes and shut it off at the key pad. Wait until the automatic 
drain allows the solution to exit the tank or use the manual drain button on the key pad. Once again, it is most important 
you are able to actually verify the solution has been drained out from the unit. By verifying the draining of the solution, 
you know the tank is not clogged. If the tank is clogged it leads to premature heating element failure and other issues. 
This procedure will also clean the water level sensor probe.  
 
If the tank is not draining please call 1-866-783-2661 or 216-587-6790 for assistance. 
 

Parts Requests 

 
Please visit homewardbath.com/support to submit a request. 
If you require additional assistance, call 866-783-2661. 
 

Warranty Information & Registration 

 
Please visit our website: homewardbath.com/warranty-registration 
 
Note serial number on the generator: ________________________          
 
Registration must be completed within 45 days of receipt to be valid. 
A full description of the warranty is available on the Homeward Bath website. 

Содержание GH21-HT

Страница 1: ...Steam Planet Superior Encore Steam Generator Installation Operation Manual 6kW 9kW 12kW 18kW 24kW Rev 6 2022...

Страница 2: ...ule Introduction 7 Reset Introduction 7 Choosing the proper location 8 Keypad Diagram 8 Keypad Introduction 9 Dual Keypad Setup 10 Common Installation Problems 11 Suggested Steam Room Layout 11 Instal...

Страница 3: ...tering or leaving b The steam head is hot Do not touch the steam head and avoid the steam near the steam head c Prolonged use of the steam system can raise excessively the internal human body temperat...

Страница 4: ...er Power Space Voltage Max Current Wire DIA 6kW 140 320ft 220 240V 27 3A 10 ro 6MM 9kW 320 460ft 220 240V 41A 10 ro 6MM 12kW 460 700ft 220 240V 55A 6 ro 10MM 18kW 700 920ft Two 220 240V Lines Two 41A...

Страница 5: ...ed 11ft power cable External temperature sensor External temperature sensor foundation 12ft power box extension cable 9 5ft cable for keypad or generator connection 1ft light cable 25ft cable for sing...

Страница 6: ...Wiring Diagram...

Страница 7: ...V with 2 pin SIM2 54 connector Module Introduction The system consists of power box GH21 PB control module GH21EE Bluetooth module GH21 BT and steam module GS08 HW Power box GH21 PB provides 14v DC Th...

Страница 8: ...ft between steam generator and any other object 9 The place where the machine is installed must be accessible for cleaning and possible service work 10 The steam generator should be in a close proximi...

Страница 9: ...Keypad Introduction...

Страница 10: ...e Icon is highlighted on the keypad the current temperature will be displayed 2 Press and hold the dial in the steam room temperature will be displayed and the thermometer in the display will start to...

Страница 11: ...e reading Power box issues Make sure the wiring that connects the power box to the keypad and steam generator is not damaged Suggested Steam Room Layout Installation 1 For wall mounting Steam generato...

Страница 12: ...ctor b Drain G1 2 thread connector Must be copper for at least first 3ft from the generator c Steam outlet G3 4 thread connector d Steam line Must use copper Insulate the line with high temp 212 plus...

Страница 13: ...ture resistant material Outlet should be no closer than 10in from the floor and no higher that 15in from the floor The steam outlet should be installed face down Wrap a few circles Teflon tape around...

Страница 14: ...Circuit Diagram for 6kW 9kW...

Страница 15: ...Circuit Diagram for 12kW...

Страница 16: ...ning Both openings go to the tank Fill the tank until the solution starts to come out of the steam outlet or the pressure relief valve opening Replace the steam line or the pressure relief valve then...

Отзывы: