36. The open-circuit voltage, for as many adjustments as possible, must
never exceed the values relating to the various cases shown in the following
table:
Case Working conditions
Open-circuit voltage
1
Places with increased
risk of electric shock
DC current: 113V
peak value
AC current: 68V
peak value and 48V
effective
2
Places without
increased risk of electric
shock
DC current: 113V
peak value
AC current: 113V
peak value and 80V
effective
3
Torches held
mechanically with
increased protection for
the operator
DC current: 141V
peak value
AC current: 141V
peak value and
100V effective
4
Plasma cutting
DC current: 500V
peak value
37. In case 1, the dc machines with rectifier must be built in such a way that,
in case of a fault developing in the rectifier (for example open circuit, short
circuit or lack of power), the permitted values cannot be exceeded. The
welding machines of this type can be marked with the symbol:
S
38. Before opening the machine switch off the machine and disconnect it
from the power socket.
39. Only personnel authorised by this company can carry out maintenance
on the machine.
WELDING PROTECTIVE UTTILITIES
1. Welding helmet with filter shade at least 10
2. Welding gloves
3. Welding apron and cloth
4. Welding boots
RISK OVERVIEW
1. Risk of electric shock
2. Ultraviolet light and light radiation
3. Risk of inhaling gas fumes and dust particles
4. Burns
5. Noise
NOTE
1.
It is forbidden to operate a machine with damaged insulation of the
welding torch or supply cable.
2. Never operate the machine taken down or damaged covers.
3.
It is forbidden to operate the machine in wet environments and outdoors
Содержание MG-160