Group 4

Nodes in this group are turned ON or OFF or set to a specific dim level when the ZTW230 is controlled re-
motely.  You can place up to 5 nodes in each group.
If controlling dimmers, for best results, associate the dimmers into the group first.

Configuration

The ZTW230  supports the Configuration command.

The ZTW230 can be configured to operate slightly differently than how it works when you first install it. Using the
configuration command you can adjust other operational characteristics of the ZTW230 as follows:

Set Ignore Start Level Bit When Transmitting Dim Command

Suspend Group 4

Night Light

Invert Switch

Ignore Start Level When Receiving Dim Commands

•   Adjusting Dim Rate
•   On/Off Command dim rate (excluding ALL ON/ALL OFF commands)
•   Local Control Dim Rate
•   ALL ON/ALL OFF Dim Rate
•   Disable Group 4 During a Dim Command
•   Enable Shade Control Group 1
•   Enable Shade Control Group 2
•   Enable Shade Control Group 3
•   LED Transmission Indication
•   Poll Group 1
•   Poll Group 1: Minutes

The ZTW230 simulates the operation of a dimmer.  Using configuration commands you can adjust the dimming
parameters as though it were a dimmer.
You can use a ZTH200 to send Configuration commands. (Refer to the Setup Menu, Configuration section)

Set Ignore Start Level Bit When Transmitting Dim Commands

•   Parameter No: 1
•   Length: 1 Byte
•   Valid Values  = 0 or 1 (default value is 1)

The ZTW230 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level
embedded in it.  A dimmer receiving this command will start dimming from that start level. However, the
command also has a bit that indicates whether the dimmer should ignore the start level.  If the bit is set to 1,
the dimmer will ignore the start level and instead start dimming from its current level.  If this bit is set to 0, the
dimmer will not ignore the start level.

Note that many ACT Z-Wave enabled dimmers have the configuration option to ignore the start level no
matter how you configure the ZTW230

Suspend Group 4

•   Parameter No: 2
•   Length: 1 Byte
•   Valid Values  = 0 or 1 (default value is 0)

You may wish to disable transmitting commands to Z-Wave devices that are in Group 4 without “disassociating”
those devices from the group. Setting parameter 2 to the value of 1 will stop the ZTW230  from transmitting to
devices that are “associated” into Group 4.

Night Light

•   Parameter No: 3
•   Length: 1 Byte
•   Valid Values = 0 or 1 (default  value is 0)

Содержание ZTW230

Страница 1: ... on how to include this module in the RF network 1 Remove the paddle Using small screw driver push out the paddle through holes in back side of mounting plate The paddle can also be pried out from the face from the top or the bottom of the paddle 2 Remove the four screws through the retaining ring holding the Trim ring to the mounting plate This will allow removal of Trim ring When removing the Tr...

Страница 2: ... breaker to service the load Auxiliary Switch An AS200 auxiliary switch providing 3 or 4 Way operation on the ZTW230 will also control Group 2 and 3 with multiple taps Single tap Group 1 ON OFF Hold Group 1 Dim Bright Double tap Group 2 ON OFF Tap Press hold Group 2 Dim Bright and Triple tap Group 3 ON OFF Double Tap Press hold Group 3 Dim Bright Association Refer to your controllers instructions ...

Страница 3: ...onfiguration commands you can adjust the dimming parameters as though it were a dimmer You can use a ZTH200 to send Configuration commands Refer to the Setup Menu Configuration section Set Ignore Start Level Bit When Transmitting Dim Commands Parameter No 1 Length 1 Byte Valid Values 0 or 1 default value is 1 The ZTW230 can send Dim commands to Z Wave enabled dimmers The Dim command has a start le...

Страница 4: ...lid Values See next Note that this only affects a level that is reported or possibly sent by the ZTW230 since the ZTW230 does not control a load For example There are 3 sets of parameters that can adjust the dimming rate of the ZTW230 1 One set to control how fast the dim rate is when the dimmer receives a Z Wave command excluding ALL ON or ALL OFF command 2 One set to control how fast the dim rat...

Страница 5: ...vices in Group 4 during this particular occurrence set Parameter 13 to the value of 1 Enable Shade Control Group 1 Parameter 16 Length 1 Byte Valid Values 0 or 1 default value is 0 The ZTW230 can control shade control devices via its group 1 if this configuration parameter is set to 1 Enable Shade Control Group 2 Parameter 14 Length 1 Byte Valid Values 0 or 1 default value is 0 The ZTW230 can cont...

Страница 6: ...heZRW230supportsthePowerlevelcommand The Powerlevel command allows controllers to set and get the RF transmit power level of a node and test specific links between nodes with specific RF transmit power Refer to your controller s instructions if it supports this command for more information This command is typically used by professional installers SUC Support There must be aStatic Update Controller...

Отзывы: