Resetting to factory status
In order to reset components to factory status, proceed
as follows:
• Press the first programming button for approx.
6 seconds. The quickly flashing channel LED
indicates delete mode.
•
Release the button.
•
Press the button again for approx. 3 seconds until
the channel LED flashes very slowly.
•
Release the button.
•
The channel LED goes dark after a short time and
the device is set back to the factory settings.
9
Maintenance and cleaning
This product is maintenance-free.
Repairs are only to be done by trained profes-
sionals.
HMW-LC-Dim1L-DR:
The device is provided with an internal device fuse for
protecting the Triac from greater current loads. If the
device becomes overloaded and the fuse is blown, it
can be replaced by a technician!
Disconnect the mains power before removing
the device (switch the circuit breaker off)!
Work on the 230 V network is only permitted by
qualified electricians (in accordance with VDE
0100).
Replace fuses with same type fuses only
(micro-fuse 5 x 20 mm, 1 A slow)!
10 Technical specifications
Communication:
RS485-Bus
Housing dimensions:
Standard DIN rail housing
with 2 TE wide
87 x 35 x 64 mm
(L x W x H)
HMW-LC-Sw2-DR
Outputs:
2 independent
potential-free
relay switching outputs
Switching capacity:
230 V / 50 Hz / 16 A (per
relay), load both channels
max. 25 A
Power supply:
24 V / DC
Current consumption:
70 mA (max.)