Technical specifications
Technical specifications
40
41
12
Technical specifications
Device short description:
HM-ES-PMSw1-PI-DN-R5
Supply voltage:
230 V/50 Hz
Current consumption:
10 A max.
Power consumption in standby:
< 0.6 W
Degree of protection:
IP20
Ambient temperature:
-10 to +35 °C
Degree of pollution:
2
Measurement category:
CAT II
Radio frequency:
868.3 MHz
Receiver category:
SRD category 2
Typ. open area RF range:
300 m
Duty cycle:
< 1 % per h
Max. switching capacity:
2300 W
Load type:
ohmic load
Life expectancy relay/
switching cycle:
40000 (10 A, ohmic load)
Relay:
Shutter contact, 1-pole, μ contact
Switch type:
independently mounted switch
Operating mode:
S1
Withstand voltage:
2500 V
Protection class:
I
Method of operation:
Type 1 B
Dimensions (W x H x D):
59 x 122 x 40 mm (not incl. mains plug)
Weight:
167 g
Measuring range
Resolution
Accuracy
Power
0 to 2300 W
0.01 W
1 %
± 0.03 W*
Current
0 to 10 A
1 mA
1 %
± 1 mA*
Voltage
200 to 255 V
0.1 V
0.5 %
± 0.1 V
Frequency
48.72 to 51.27 Hz
0.01 Hz
0.1 %
± 0.01 Hz
*Frequency range: 2 Hz to 2 kHz
Subject to technical changes.
Instructions for disposal
Do not dispose of the device with regular domestic waste.
Electronic equipment must be disposed of at local collection
points for waste electronic equipment in compliance with the
Waste Electrical and Electronic Equipment Directive
.
Information about conformity
The CE Marking is simply an official symbol relating to the free
movement of a product; it does not warrant a product’s charac-
teristics.