![Homematic IP HmIP-FCI1 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/homematic-ip/hmip-fci1/hmip-fci1_installation-instructions-and-operating-manual_2153889031.webp)
31
Start-up
to the connecting cables IN1 (orange)
(E)
and
GND (black)
(F)
according to the connection dia-
gram (
see Figure 2
).
The device can be installed inside a flush-moun-
ted box along with the pushbutton and switch as
long as it does not contain any live wires.
The connecting cables for the pushbutton/
switch/contact must not be longer than three
metres.
It is absolutely essential to ensure that the connec-
ting cables are laid so that they are physically sepa-
rate from cables carrying mains voltage (for ex-
ample, in separate cable ducts or wiring conduits).
The contact interface is only suitable for connec-
ting floating pushbuttons.
Do not connect the connecting cables with 230 V
mains voltage.