MAINTENANCE

!

WARNING

Never attempt to service heater while it is connected to
propane supply, operating, or hot. Severe burns can occur.

SYMPTOM

Pilot fails
to light.

Pilot lights
but goes
out when
automatic
control valve
button
is released.

Burn rate
is low.

POSSIBLE CAUSE

1. Propane supply valve closed

on propane tank(s).

2. Excess-flow check valve

closed.

3. Air in gas line.

4. Blockage in pilot orifice.
5. Piezo ignition system not

sparking.

1. Not enough warm-up time.

2. Low gas pressure.

3. Thermocouple loose or

needs to be replaced.

4. Automatic control valve

needs to be replaced.

1. Main burner valve not fully

open.

2. Plugged gas orifices.
3. Low gas pressure.

4. Low fuel supply.

REMEDY

1. Open propane supply valve

slowly.

2. Close propane supply valve on

propane tank and reopen
slowly.

3. Allow several minutes to purge

air with automatic control
valve button depressed.

4. Replace pilot orifice.
5. Adjust ignitor electrode gap to

.120". Check wire lead for
damage. Replace piezo ignitor
and/or ignitor electrode as
necessary.

1. Relight, hold automatic control

valve button in 45 seconds.

2. Check propane tank(s) for

proper gas supply.

3. Tighten connection or replace

thermocouple.

4. Replace automatic control

valve.

1. Fully open main burner valve

by turning the valve handle
towards ON position until it
stops.

2. Replace gas orifice.
3. Check gas supply; check

regulator output.

4. Consult propane gas supplier.

TROUBLE-

SHOOTING

!

WARNING

Never attempt to service heater while it is connected to
propane supply, operating, or hot. Severe burns can occur.

1. Keep heater clean.
2. Inspect heater before each use. Check connections for leaks. Apply mixture of

liquid soap and water to connections. Bubbles forming show a leak that must be
corrected. Correct all leaks at once.

3. Inspect hose/regulator assembly before each use. If hose is highly worn or cut,

replace.

4. Have heater inspected yearly by service person.

Содержание HP275

Страница 1: ...ARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION AND OR CARBON MONOXIDE POISONING ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IFYOUNEEDASSISTANCEORHEATERINFORMATIONSUCHASANINSTRUCTIONS M...

Страница 2: ...questions about heater use Other standards govern the use of fuel gases and heat producing products for specific uses Your local authorities can advise you about these Carbon Monoxide Poisoning Some people are more affected by carbon monoxide than others Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness and or nausea If you have these signs the heater may not be wo...

Страница 3: ...er away from strong drafts water spray rain or dripping water Never attach duct work to heater Never block air inlet bottom of shell or air outlet around top of shell of heater Keep children and animals away from heater Locate heater on stable and level surface if heater is hot or operating Minimum heater clearances from combustibles Sides 4 feet Top 6 feet 2 inches Install and use heater with car...

Страница 4: ...m dealer where you bought heater UNPACKING Figure 1 HP275 Pilot Inlet Connector Hose Regulator Assembly Note Debris Shield Not Shown THEORY OF OPERATION The Fuel System The hose regulator assembly attaches to the propane gas supply This provides fuel to the heater The Ignition System The piezo ignitor lights the pilot fuel supply The Automatic Control System The automatic control valve shuts off t...

Страница 5: ...ratures Two or more 100 pound tanks or one larger tank may be needed in colder weather Your local propane gas dealer will help you select the proper supply system SPECIFICATIONS Average Temperature F At Tank Location 60 40 32 20 10 0 Number Of Tanks 2 2 3 3 3 3 VENTILATION WARNING Follow the minimum fresh outside air ventilation requirements If proper fresh outside air ventilation is not provided ...

Страница 6: ...nting down Pointing vent down protects regulator from weather damage Supply Valve POL Fitting Hose Regulator Vent pointing down 3 Connect hose to the inlet connector Tighten firmly using 9 16 wrench IMPORTANT Use extra hose or piping if needed Install extra hose or piping between hose regulator assembly and propane tank You must use the regulator supplied with heater even if propane tank has one H...

Страница 7: ...ons LP PFA OV 006 Gas Controls TrashCan Piezo Ignitor Button Main Burner Valve Handle Continued 5 Check all connections for leaks Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak that must be corrected OPERATION To Start Heater 1 Follow all installation ventilation and safety information 2 Locate heater on stable and level surface Make sure strong drafts do not blow...

Страница 8: ...trap after stacking 6 If pilot light goes out repeat steps 4 and 5 7 When pilot remains lit fully open main burner valve Do this by turning main burner valve handle towards the ON position until it stops Note Arrows on main burner valve handle show directions for ON and OFF Main Burner Valve Handle Figure 5 Main Burner Valve Handle Location To Stop Heater 1 Tightly close propane supply valve on pr...

Страница 9: ...rol valve button depressed 4 Replace pilot orifice 5 Adjust ignitor electrode gap to 120 Check wire lead for damage Replace piezo ignitor and or ignitor electrode as necessary 1 Relight hold automatic control valve button in 45 seconds 2 Check propane tank s for proper gas supply 3 Tighten connection or replace thermocouple 4 Replace automatic control valve 1 Fully open main burner valve by turnin...

Страница 10: ...10 099238 NOTES ...

Страница 11: ...11 099238 NOTES ...

Страница 12: ...EXTRON UNE DIVISION DE TEXTRON S A R L Z I du Vert Galant Rue du Chateau Rue de la Garenne 95310 Saint Quen L Aumone France NETHERLANDS HOMELITE TEXTRON DIVISION OF TEXTRON ATLANTIC HDQS Europe Africa and Middle East Haverstraat 24 2153 GB Nieuw Vennep The Netherlands AUSTRALIA HOMELITE DIVISION OF TEXTRON PACIFIC LIMITED HEADQUARTERS 22 Terra Cotta Drive Blackburn 3130 Victoria Australia CANADIAN...

Отзывы: